Cooling High Power Dissipating Artificial Intelligence (AI) Chips Using Refrigerant

DOI: 10.4236/jectc.2024.132002, PP. 35-49

Keywords: Artificial Intelligence, Thermal Control, Server Systems, Vapor Compression Refrigeration Cycle, Server Cooling

Full-Text   Cite this paper   Add to My Lib

Abstract:

High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.

References

[1]  Filippis, R.D. and Foysal, A.A. (2024) Harnessing the Power of Artificial Intelligence in Neuromuscular Disease Rehabilitation: A Comprehensive Review and Algorithmic Approach. Advances in Bioscience and Biotechnology, 15, 289-309.
https://doi.org/10.4236/abb.2024.155018
[2]  Wei, J. (2008) Challenges in Cooling Design of CPU Packages for High-Performance Servers. Heat Transfer Engineering, 29, 178-187.
https://doi.org/10.1080/01457630701686727
[3]  Moon, K., Son, H. and Lee, K. (2023) Advanced Packaging Technologies in Memory Applications for Future Generative AI Era. 2023 International Electron Devices Meeting, San Francisco, 09-13 December 2023, 1-4.
https://doi.org/10.1109/iedm45741.2023.10413890
[4]  Kumar, R., Khatri, S.K. and Jose Divan, M. (2020) Effect of Cooling Systems on the Energy Efficiency of Data Centers: Machine Learning Optimisation. 2020 International Conference on Computational Performance Evaluation, Shillong, 02-04 July 2020, 596-600.
https://doi.org/10.1109/compe49325.2020.9200088
[5]  Hutcheson, G.D. (2009) The Economic Implications of Moore’s Law. In: Hull, R., Jagadish, S., et al., Eds., Springer Series in Materials Science, Springer, 11-38.
https://doi.org/10.1007/978-3-540-74559-4_2
[6]  Ren, H. (2022) Artificial Intelligence and Future Legal System: The Right to Access Electrical Energy of Artificial Intelligence. Open Journal of Social Sciences, 10, 447-458.
https://doi.org/10.4236/jss.2022.1012030
[7]  Scott, A.W. (1974) Cooling of Electronic Equipment. Wiley.
[8]  Trutassanawin, S. and Groll, E.A. (2004) Review of Refrigeration Technologies for High Heat Dissipation Electronics Cooling.
https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=1677&context=iracc
[9]  Schmidt, R.R. and Notohardjono, B.D. (2002) High-End Server Low-Temperature Cooling. IBM Journal Research and Development, 46, 739-751.
https://doi.org/10.1147/rd.466.0739
[10]  Mongia, R., Masahiro, K., DiStefano, E., Barry, J., Chen, W., Izenson, M., et al. (2006) Small Scale Refrigeration System for Electronics Cooling within a Notebook Computer. Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems 2006, San Diego, 30 May-02 June 2006, 751-758.
https://doi.org/10.1109/itherm.2006.1645421
[11]  Erkinaci, T., Coskun, F., Cotur, A., Onler, R. and Serincan, M.F. (2024) Experimental and Numerical Investigation of a Compact Vapor Compression Refrigeration System for Cooling of Avionics in Harsh Environments. Applied Thermal Engineering, 236, Article 121663.
https://doi.org/10.1016/j.applthermaleng.2023.121663
[12]  Čaja, A., Čajová Kantová, N., Kapjor, A. and Vantúch, M. (2022) Comparison of Performance Parameters of Four Types of Refrigerants. MATEC Web of Conferences, 369, Article 04007.
https://doi.org/10.1051/matecconf/202236904007
[13]  Çengel, Y.A. and Boles, M.A. (2019) Thermodynamics: An Engineering Approach. 9th Edition, Mcgraw-Hill Education.
[14]  The Chemours Company (2016) Thermodynamic Properties of Opteon™ XP10 (R-513A) SI Units.
[15]  The Engineering ToolBox (2005) Ammonia-NH3-Thermodynamic Properties.
https://www.engineeringtoolbox.com/ammonia-d_971.html
[16]  IIAR (2008) Appendix A Thermodynamic Property Tables. In Ammonia Data Book 2nd Edition (pp. A1-A42).
https://web.iiar.org/membersonly/PDF/CO/databook_AppA.pdf
[17]  DuPont (2004) Thermodynamic Properties of DuPont Suva 95 Refrigerant (R-508B).
[18]  The Chemours Company (2016) Freon™ 22 Refrigerant (R-22) Thermodynamic Properties (SI Units).
[19]  Bhattacharjee, S. (2023) Temperature Saturation Table, R-12.
https://energy.sdsu.edu/testhome/tablesModule/tablesPC/TSatR12.html
[20]  Bhattacharjee, S. (2023) Superheated Vapor Table, R-12.
https://energy.sdsu.edu/testhome/tablesModule/tablesPC/superR12.html
[21]  The Chemours Company (2023) Freon™ 410A Refrigerant (R-410A) Thermodynamic Properties (SI Units).
[22]  The Chemours Company (2018) Opteon™ YF Automotive Refrigerant (HFO-1234yf) Thermodynamic Properties of Opteon™ YF SI Units.
[23]  Ciconkov, R. (2018) Refrigerants: There is still No Vision for Sustainable Solutions. International Journal of Refrigeration, 86, 441-448.
https://doi.org/10.1016/j.ijrefrig.2017.12.006
[24]  Cole, B. (2023) R-513A Refrigerant Fact & Info Sheet.
https://refrigeranthq.com/r-513a-refrigerant-fact-info-sheet/
[25]  Vaghela, J.K. (2017) Comparative Evaluation of an Automobile Air—Conditioning System Using r134a and its Alternative Refrigerants. Energy Procedia, 109, 153-160.
[26]  Niu, B. and Zhang, Y. (2007) Experimental Study of the Refrigeration Cycle Performance for the R744/R290 Mixtures. International Journal of Refrigeration, 30, 37-42.
[27]  Hense, D.L. and Karnopp, J. (2022) Refrigerant Replacement from HFC to HC in a Medical Ultra-Low Temperature Appliance: Experimental and Simulation Approach.
https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=3375&context=iracc
[28]  Environmental Protection Agency (2024) Phasing Out HCFC Refrigerants to Protect the Ozone Layer.
https://www.epa.gov/sites/default/files/2015-07/documents/phasing_out_hcfc_refrigerants_to_protect_the_ozone_layer.pdf
[29]  Cabello, R., Torrella, E., Llopis, R., Sánchez, D. and Larumbe, J.A. (2013) Energy Influence of the IHX with R22 Drop-In and Long-Term Substitutes in Refrigeration Plants. Applied Thermal Engineering, 50, 260-267.
https://doi.org/10.1016/j.applthermaleng.2012.06.008
[30]  Blanco Ojeda, F.W.A., Almeida Queiroz, M.V., Marcucci Pico, D.F., dos Reis Parise, J.A. and Bandarra Filho, E.P. (2022) Experimental Evaluation of Low-Gwp Refrigerants R513A, R1234yf and R436A as Alternatives for R134a in a Cascade Refrigeration Cycle with R744. International Journal of Refrigeration, 144, 175-187.
https://doi.org/10.1016/j.ijrefrig.2022.08.010
[31]  Heredia-Aricapa, Y., Belman-Flores, J.M., Mota-Babiloni, A., Serrano-Arellano, J. and García-Pabón, J.J. (2020) Overview of Low GWP Mixtures for the Replacement of HFC Refrigerants: R134a, R404A and R410a. International Journal of Refrigeration, 111, 113-123.
https://doi.org/10.1016/j.ijrefrig.2019.11.012
[32]  Chen, W. (2008) A Comparative Study on the Performance and Environmental Characteristics of R410A and R22 Residential Air Conditioners. Applied Thermal Engineering, 28, 1-7.
https://doi.org/10.1016/j.applthermaleng.2007.07.018

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133