Objectives: This study aims to evaluate the level of X-ray doses used in childhood’s head as Local Diagnostic Reference Levels (LDRLs) in computed tomography (CT) at a university hospital in Côte d’Ivoire. The Diagnostic Reference Level (DRL) have been set up and used to prevent unusually high radiation doses used in radiology departments and is therefore an optimization tool for practices and procedures in medical X-ray imaging for the radiation protection of patients. Methods: A prospective study of volume CT dose index (CTDIvol) and dose length product (DLP) was performed on images of childhood’s head obtained from a CT-scanner of 64 bars equipped with the tube current modulation capability and manufactured by Hitachi Medical System. 122 CT-scan data from 55 childhood’s head were analyzed. The scan data were stratified in four age groups: <1.5 years, 1.5 - 5.5 years, 5.5 - 10.5 years, and 10.5 - 16 years. Results: The 75th percentile of CTDIvol and DLP (set as LDRL) obtained with respect to the stratified age groups are: 22.5 mGy and 452.5 mGy∙cm, 27.7 mGy and 690.6 mGy∙cm, 28 mGy and 722.4 mGy∙cm, 33.6 mGy and 736.8 mGy∙cm respectively. These outcome values increase with respect to the age of pediatric patients and are comparable to DRLs values obtained internationally. Conclusions: Obtaining good image quality while using low dose in children’s head computed tomography for radiation protection require to setup more surveys in Côte d’Ivoire for regional and national DRL. We proposed through this survey LDRLs in terms of CTDIvol and DLP, comparable to international DRLs values. This survey will be strengthened by additional surveys in order to obtain national DRLs for the radiation protection of the child patient in Côte d’Ivoire.
References
[1]
United Nations (2021) Report of the United Nations Scientific Committee for the Study of Ionizing Radiation. Sixty-Seventh and Sixty-Eighth Sessions.
[2]
Vañó, E., Miller, D.L., Martin, C.J., Rehani, M.M., Kang, K., Rosenstein, M., et al. (2017) ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Annals of the ICRP, 46, 1-144 https://doi.org/10.1177/0146645317717209
[3]
Monnehan, G.A., Anouan, K.J., Onoma, D.P., Yao, K.B., Kouadio, L.D., Koua, A.A. and Dali, P.A.T. (2009) Determination of Diagnostic Reference Levels in Cote d’Ivoire: The Cases of the Chest X-Ray Standard front and Abdomen Adult in the District of Abidjan and in the Region of Sud Comoé. Revue Ivoirienne des Sciences et Technologie, 14, 45-53.
[4]
Alzen, G. and Benz-Bohm, G. (2011) Radiation Protection in Pediatric Radiology. Deutsches Ärzteblatt International, 108, 407-414. https://doi.org/10.3238/arztebl.2011.0407
[5]
Monnehan, G.A., Silue, K.A., Djagouri, K., Koua, A.A., Gogon, B.D.L.H., Dali, T.P., Kezo, P.C. and Konate, I. (2017) Determination of Diagnostic Reference Levels in Côte d’Ivoire: Case of the Adult Skull Computed Tomography in the District of Abidjan. International Journal of Science and Research (IJSR), 6, 422-425.
[6]
Wagner, F., Bize, J., Racine, D., Le Coultre, R., Verdun, F., Trueb, P.R. and Treier, R. (2018) Derivation of New Diagnostic Reference Levels for Neuro-Paediatric Computed Tomography Examinations in Switzerland. Journal of Radiological Protection, 38, 1013. https://doi.org/10.1088/1361-6498/aac69c
[7]
Kanal, K.M., Butler, P.F., Chatfield, M.B., Wells, J., Samei, E., Simanowith, M., Golden, D., Gress, D.A., Burleson, J., Sensakovic, W.F., Strauss, K.J. and Frush, D. (2022) U.S. Diagnostic Reference Levels and Achievable Doses for 10 Pediatric CT Examinations. Radiology, 302, 164-174. https://doi.org/10.1148/radiol.2021211241
[8]
Kamdem, E.F., Samba O.N., Manemo, C.T., Kouam, F.B.B., Abogo, S., Tambe, J., Amougou, J.C.M., Guegang, E., Zeh, O.F., Moifo, B., Nguemgne, C., Nana N.F.N. and Fotue, A.J. (2022) Establishment of Local Diagnostic Reference Level For Routine Paediatric Computed Tomography Examinations in Bafoussam West Cameroon. Radiation Protection Dosimetry, 198, 815-820. https://doi.org/10.1093/rpd/ncac143
[9]
(2020) The Federal Agency for Nuclear Control (FANC). CT Scanners. https://afcn.fgov.be/fr/professionnels/professions-medicales/applications-radiologiques/nrd/CTscanners
[10]
Benmessaoud, M., Dadouch, A., Talbi M., Tahiri, M. and El-ouardi, Y. (2020) Diagnostic Reference Levels for Paediatric Head Computed Tomography in Morocco: A Nationwide Survey. Radiation Protection Dosimetry, 191, 400-408. https://doi.org/10.1093/raddos/ncaa170
[11]
Vassileva, J., et al. (2015) A Study to Establish International Diagnostic Reference Levels for Paediatric Computed Tomography. Radiation Protection Dosimetry, 165, 81-85. https://doi.org/10.1093/rpd/ncv113