Determination of Timer Error and Evaluation of Its Effect on Dose for OB6, GammaBeam X200 and X-Ray Irradiators at the Secondary Standard Dosimetry Laboratory in Nigeria

DOI: 10.4236/wjnst.2024.142007, PP. 118-130

Keywords: Timer Error, Irradiation, SSDL, Irradiators, Dose Accuracy

Full-Text   Cite this paper   Add to My Lib

Abstract:

Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL; and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.

References

[1]  Massey, J.B. (1970) Manual of Dosimetry in Radiotherapy. IAEA-TRS No. 110, International Atomic Energy Agency, Vienna.
[2]  Cohen, M. and Mitchell, J.S. (1984) Cobalt-60 Teletherapy: A Compendium of International Practice. International Atomic Energy Agency, Vienna.
[3]  National Council on Radiation Protection and Measurements (1981) Dosimetry of X-Ray and Gamma-Ray Beams for Radiation Therapy in the Energy Range 10 kev to 50 Mev. NCRP Report No. 69, Washington DC.
[4]  International Atomic Energy Agency (1994) Calibration of Dosimeter Used in Radiotherapy. IAEA-TRS 374, Vienna.
[5]  International Atomic Energy Agency (2000) Absorbed Dose Determination in External Beam Radiotherapy. An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Technical Report Series No. 398.
[6]  Samat, S.B., Evans, C.J., Kadni, T. and Dolah, M.T. (2008) The Determination of Timer Error and Its Role in the Administration of Specified Doses. Jurnal Fizik Malaysia, 29.
[7]  Orton, C.G. and Seibert, J.B. (1971) The Measurement of Teletherapy Unit Timer Error. Physics in Medicine & Biology, 17, 198-205.
https://doi.org/10.1088/0031-9155/17/2/005
[8]  International Atomic Energy Agency (2005) Radiation Oncology Physics. Non-Serial Publications.
[9]  Samat, S.B., Evans, C.J. and Kadni, T. (2001) Timer Error: The Possibility of Confusion Arising from Two Different Sign Convention. British Journal of Radiology, 74, 290-291.
https://doi.org/10.1259/bjr.74.879.740290