This study aimed to characterize and estimate the pollution potential of wastewater discharged into the Mda River, due to effluents from the city’s municipal slaughterhouse, with the goal of formulating recommendations for appropriate treatment to reduce the serious impact on not only public health and the environment, but also on the city’s socio-economic activities. A systematic inventory was conducted over the period from January to December 2018. Furthermore, physico-chemical analyses show that the slaughterhouse’s wastewater reveals a significant pollutant load in terms of organic matter, with COD (average = 280 mg/L), BOD5 (average = 186 mg/L), TSS (average = 300 mg/L), and mineral matter expressed as Chlo-rides (average = 350.5 mg/L), Electrical Conductivity (average = 2690 μs/cm), with a pH of 7.57. The average concentration of ammonium ions is around 11.4 mg/L, while that of Nitrates is approximately 1.74 mg/L. Despite the high organic load of this wastewater (BOD5/COD ratio = 0.66 and TSS/BOD5 = 1.66), it shows satisfactory biodegradability. The examination of the COD/BOD5 ratio = 1.50 highlights the biodegradable nature of the wastewater from the city’s municipal slaughterhouse, for which treatment appears to be entirely appropriate.
References
[1]
Lovett, D.A., Travers, S.M. and Davey, K.R. (1984) Activated Sludge Treatment of Abattoir Wastewater—I. Influence of Sludge Age and Feeding Pattern. Water Research, 18, 429-434. https://doi.org/10.1016/0043-1354(84)90150-7
[2]
Couillard, D. and Gariepy, S. (1990) Faisabilité du procédé aérobie thermophile pour un effluent d’abattoir. The Canadian Journal of Chemical Engineering, 68, 1018-1023. https://doi.org/10.1002/cjce.5450680618
[3]
Borja, R. and Duran, M.M. (1993) Influence of the Support on the Kinetics of Anaerobic Purification of Slaughterhouse Wastewater. Bioresource Technology, 44, 57-60. https://doi.org/10.1016/0960-8524(93)90208-S
[4]
Reginatto, V., Teixeira, R.M., Pereira, F., Schmidell, W., Furigo, A., Menes, R., Etchebechere, C. and Soqres, H.M. (2003) Anaerobic Ammonium Oxidation in a Bioreactor Treating Slaughterhouse Wastewater. Brazilian Journal of Chemical Engineering, 22, 593-600. https://doi.org/10.1590/S0104-66322005000400012
[5]
Brissaud, G.F. (2002) Etude des limites de l’épuration par infiltration sur sabledes eaux usées fortement chargées en matières oxydables de l’abattoir de Ougadougou au Burkina Faso. Sud Sciences & Technologies, 9, 34-41.
[6]
Asselin, M., Blais, J.-F., Drogui, P. and Benmoussa, H. (2005) Utilisation de l’électrocoagulation pour le traitement des eaux usées d’abattoir. 21st Congress Eastern Canada Regional of the Canadian Water Quality Association, Quebec, 4 November 2005.
[7]
ISO 5667-3:2024 (2003) Water Quality—Sampling: Part 3: Guidance on the Preservation and Handling of Water Samples. https://www.iso.org/standard/33486.html
[8]
Rodier, J. (1996) L’analyse de l’eau naturelle, eaux résiduaires, eau de mer. 8éme édition, 1383 panadienne sur la Qualité de l’Eau. Québec, Denod, Paris.
[9]
DIN (Deutsche Industrie Normes) (1992) Détermination de la Demande Biologique en Oxygène (DBO) selon DIN Laboratoire National de l’Environnement-Rabat.
[10]
(DCO) selon DIN 38409-H52 (1992) Laboratoire National de l’Environnement-Rabat.
[11]
DIN (Deutsche Industrie Normes) (1993) Dosage des nitrates par méthode photométrique avec 2,6-diméthylphénol (selon DIN 38405-D9-2). Laboratoire National de l’Environnement-RDC. Rabat.
[12]
DIN (Deutsche Industrie Normes) (1993) Dosage des nitrites par méthode photométrique (selon ISO 6777 resp en 2677). Laboratoire National de l’Environnement. Rabat.
[13]
Madhav, S., Ahamad, A., Singh, A.K., Kushawaha, J., Chauhan, J.S., Sharma, S. and Singh, P. (2020) Water Pollutants: Sources and Impact on the Environment and Human Health. In: Pooja, D., Kumar, P., Singh, P. and Patil, S., Eds., Sensors in Water Pollutants Monitoring: Role of Material, Springer, Singapore, 43-62. https://doi.org/10.1007/978-981-15-0671-0_4
[14]
Belghyti, D., El Guamri, Y., Ztit, G., et al. (2009) Caractérisation physico-chimique des eaux usées d’abattoir en vue de la mise en œuvre d’un traitement adéquat: Cas de Kénitra au Maroc. Afrique Science: Revue Internationale des Sciences et Technologie, 5, 199-216. https://doi.org/10.4314/afsci.v5i2.61730
[15]
Kbibch, A., El khokh, K., Elkharrim, K.H. and Belghyti, D. (2011) Analyse de la pollution de l’oued Mda par les eaux usées domestiques de la ville de Souk Elarba du Gharb. MAROC. ScienceLib Editions Mersenne, 3, Article No. 110203.
[16]
Ministère de l’Environnement du Maroc (2002) Normes marocaines, Bulletin officiel du Maroc. N° 5062 du 30 ramadan 1423, Rabat.
[17]
Miranda, L.A.S., Henriques, J.A.P. and Monteggia, L.O. (2005) A full-Scale Uasb Reactor for Treatment of Pig and Cattle Slaughterhouse Wastewater with a High Oil and Grease Content. Brazilian Journal of Chemical Engineering, 22, 601-610. https://doi.org/10.1590/S0104-66322005000400013
[18]
Thomas, O. (1995) Diagnostic de sols pollués par des hydrocarbures aromatiques polycycliques (HAP) a l’aide de la spectrophotométrie UV. https://theses.hal.science/tel-00837762
[19]
Massé, D.I. and Masse, L. (2000) Treatment of Slaughterhouse Wastewater in Anaerobic Sequencing Batch Reactors. Canadian Agricultural Engineering, 42, 131-137.
[20]
ONEP (1998) Approche de la typologie des eaux usées urbaines au Maroc. ONEP et GTZ. Rabat.
[21]
Hamdaoui, R. (2006) Caractérisation physico-chimique et traitement des eaux usées résiduaires de la société SETEXAME. Kenitra. Mémoire DESA, Université Ibn Tofail. Kénitra.
[22]
Henze, M., Harremoes, P., Jansen, J.L.C. and Avrin, E. (1997) Wastewater Treatment. 2nd Edition, Springer, Berlin.
[23]
EL Khokh, K., Kbibch, A., Elkharrim, K.H. and Belghyti, D. (2012) Evaluation de la charge polluante des eaux usées de la ville de Mechraa Belksiri (MAROC). Science Lib Editions Mersenne, 4, Article No. 121104.