Impact of the Condition of Drinking Water Supply Networks on the Quality of Water Intended for Consumption: The Case of the Network in the Commune of Daloa (Central West of Côte d’Ivoire)

DOI: 10.4236/jwarp.2023.1512036, PP. 677-691

Keywords: Pipe, Water Supply Network, Drinking Water, Daloa

Full-Text   Cite this paper   Add to My Lib

Abstract:

The potability of drinking water depends not only on the source and the treatment system, but also on the quality of the waterworks. In fact, the quality of drinking water is considerably degraded by the dilapidated state and lack of maintenance of drinking water networks. In Côte d’Ivoire, the majority of drinking water networks in the various towns are ageing. In Daloa, despite the efforts made by the company in charge of water treatment and distribution to make the water drinkable, the water at consumers’ taps is often colored, has an unpleasant aftertaste and settles after collection. As a result, people are concerned about the potability of tap water, and some are turning to alternative sources of drinking water of unknown quality. In order to determine the factors responsible for the deterioration in water color and taste, as well as the sectors of the network most affected, a diagnosis of the network’s equipment was carried out. Water samples taken from the network were analyzed for color and turbidity. The diagnosis revealed that most of the equipment (suction pads, valves, drains and fire hydrants) is outdated and irregularly maintained. Analyses show that the water is more colored in cast-iron and PVC pipes than in asbestos cement pipes. Coloration values in the network range from 0 to 27 UVC for asbestos cement pipes, from 15 to 56 UCV for ductile iron pipes, and from 11 to 102 UCV for PVC pipes. On the over hand, turbidity values vary from 8.02 to 3.32 NTU for ductile cast iron pipes, 8.51 to 16.98 NTU for asbestos cement pipes and 0.9 to 6.98 NTU for PVC pipes. Old cast-iron pipes release ferric ions on contact with water, degrading their color. Old cast-iron pipes release ferric ions into the water, degrading its color. The high color values observed in the vicinity of drains are thought to be due to irregular maintenance of the network. In fact, after network maintenance, a reduction rate ranging from 2% to 73% is observed for turbidity, while for color, the rate varies from 5% to 72%. In short, the network’s obsolescence and irregular maintenance contribute significantly to the deterioration of water quality.

References

[1]  Erramli, H., Dermaj, A., Driss, C., Moustafa, D. Najjat, H. and Srhiri, A. (2014) étude de la dégradation d’une canalisation de conduite d’eau en béton armé. Afrique Science, 10, 1-9.
[2]  Kanakoudis, V., Tsitsifli, S., Samaras, P. and Anastasios, I.Z. (2014) Water Pipe Networks Performance Assessment: Benchmarking Eight Cases across the EU Mediterranean Basin. Water Quality, Exposure and Health, 7, 99-108.
https://doi.org/10.1007/s12403-014-0113-y
[3]  Essoyeke, B. (2014) Nouvelle approche pour le dimensionnement et l’optimisation de la gestion des réservoirs et de la qualité de l’eau potable dans les réseaux de distribution. Rapport de thèse, Université de Montréal, Montréal, 185 p.
[4]  Fofana, O., Kouassi, E.A. and Avy, S.K. (2017) Cartographie et identification des activités sources de nuisances et de pollutions dans le bassin versant du barrage du Kan de Bouake (Cote d’Ivoire). European Scientific Journal, 13, Article 303.
https://doi.org/10.19044/esj.2017.v13n5p303
[5]  Charles, G. (2017) Modèles d’optimisation stochastique pour le problème de gestion de réservoirs. Université de Montréal, Montréal, 191 p.
[6]  Renaud, E., Khedhaouiria, D., Clauzier, M., Nafi, A., Wittner, C. and Werey, C. (2012) Réduction des fuites dans les réseaux d’alimentation en eau potable Systèmes d’indicateurs et méthodologies pour la définition, la conduite et l’évaluation des politiques de lutte contre les fuites dans les réseaux d’eau potable. Rapport de recherche, 62 p.
[7]  Holguin-Gonzalez, J.E., Boets, P., Alvarado, A., Cisneros, F., Carrasco, M.C., Wyseure, G., Nopens, I. and Goethals, P.L.M. (2013) Integrating Hydraulic, Physicochemical and Ecological Models to Assess the Effectiveness of Water Quality Management Strategies for the River Cuenca in Ecuador. Ecological Modelling, 254, 1-14.
https://doi.org/10.1016/j.ecolmodel.2013.01.011
[8]  Karim, C. (2014) Maitrise des pertes sur les réseaux d’eau potable, mise en place d’un modèle de fuite multi-états en secteur hydraulique instrumenté. Rapport de thèse, école doctorale mathématique et informatique, Université de Bordeaux, Bordeaux, 134 p.
[9]  Allal, M.A., Abdelbaki, C. and Djelloul, S.S.M. (2012) Une approche qualité totale pour la gestion des réseaux d’alimentation en eau potable: Cas du groupement urbain de Tlemcen (Algérie). Editions universitaires européennes, Saarbrücken, 168 p.
[10]  Large, A. (2013) Optimisation du renouvellement des canalisations. Rapport de première année de thèse: revue bibliographique et cadre méthodologique. IRSTEA et Université de Bordeaux, Bordeaux, 109 p.
[11]  Wilfried, G.K. (2014) Milieuu urbain et accès à l’eau potable: Cas de Daloa Centre-Ouest Cote d’Ivoire. Broché, 388 p.
[12]  Yao, A.B. (2015) Evaluation des potentialités en eau du bassin versant de la Lobo en vue d’une gestion rationnelle (Centre-ouest de la Cote d’Ivoire). Thèse de Doctorat, Université Nangui Abrogoua, Abidjan, 192 p.
[13]  Gautier, K.W. (2012) Milieu urbain et accès a l’eau potable: cas de Daloa (Centre-Ouest de la Cote d’Ivoire). In: Géographie. Université Félix Houphouet Boigny, Abidjan, 364 p.
[14]  Koffi, B. (2022) Fonctionnement hydroclimatique du bassin versant de la rivière Lobo à Nibéhibé: Modélisation de la sédimentation dans la zone de captage pour l’approvisionnement en eau potable de la ville de Daloa (Centre-Ouest de la Cote d’Ivoire). Université Jean Lorougnon Guédé, Daloa, 257 p.
[15]  Gnamba, F.M., Oulai, J.G.K., Wilfried, N. and Yei, M.S. (2020) Modélisation hydraulique du réseau d’adduction d’eau potable (AEP) de la ville de Korhogo. International Journal of Innovation and Scientific Research, 52, 17 p.
[16]  Santé Canada (2015) Recommandations pour la qualité de l’eau potable au Canada: Document technique—Le pH. Bureau de la qualité de l’eau et de l’air, Direction générale de la santé environnementale et de la sécurité des consommateurs, Santé Canada, Ottawa, 48 p.
[17]  Alla, D.A., Atta, K.J.M. and Yassi, G.A. (2018). Les risques naturels et leurs manifestations dans une ville secondaire: érosion et inondation à Daloa (Centre-Ouest de la Cote d’Ivoire). Revue de Géographie Tropicale et de l’Environnement, 2, 101-113.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133