Investigation on the Fire Resistance of Cellular Steel Beam with Sinusoidal Openings

DOI: 10.4236/ojce.2023.134043, PP. 637-663

Keywords: Fire Resistance, Thermal and Structural Analysis, Cellular Steel Beam, Transient Temperature Effect

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper investigated the fire resistance of CSBs with various parameters under high temperature rise due to fire using finite element software ABAQUS. The mechanical parameters of CSBs are analyzed, including load-bearing capacity and the temperature distribution during the heating process. Through structural analysis simulation of the entire heating process, the structural response of the CSBs is divided into five stages: elastic stage, elastic-plastic stage, self-balancing stage, catenary stage and ultimate destruction stage. The results indicate that the opening diameter-to-height ratio, opening spacing-to-height ratio and load ratio significantly affect the structural responses of CSBs in fire, followed by opening shape as secondary effects. In all the numerical analyzes, CSBs are analyzed with a uniformly distributed load and having simply supported boundary conditions.

References

[1]  Chung, K.F. (2002) Composite Beams and Floor Systems Fully Integrated with Building Services. Progress in Structural Engineering & Materials, 4, 169-178.
https://doi.org/10.1002/pse.116
[2]  Lawson, R.M. (1987) Design for Openings in the Webs of Composite Beams. CIRIA/Steel Construction Institute, CIRIA Special Publication and SCI Publication 068, Ascot.
[3]  Chung, K.F., Liu, T.C.H. and Ko, A.C.H., (2001) Investigation on Vierendeel Mechanism in Steel Beams with Circular Web Openings. Journal of Constructional Steel Research, 57, 467-490.
https://doi.org/10.1016/S0143-974X(00)00035-3
[4]  Liu, T.C.H. and Chung K.F. (2003) Steel Beams with Large Web Openings of Various Shapes and Sizes: Finite Element Investigation. Journal of Constructional Steel Research, 59, 1159-1176.
https://doi.org/10.1016/S0143-974X(03)00030-0
[5]  Chung, K.F., Liu, T.C.H. and Ko, A.C.H. (2003) Steel Beams with Large Web Openings of Various Shapes and Sizes: An Empirical Design Method Using a Generalised Moment-Shear Interaction Curve. Journal of Constructional Steel Research, 59, 1177-1200.
https://doi.org/10.1016/S0143-974X(03)00029-4
[6]  Bailey, C. (2004) Indicative Fire Tests to Investigate the Behaviour of Cellular Beams Protected with Intumescent Coatings. Fire Safety Journal, 39, 689-709.
https://doi.org/10.1016/j.firesaf.2004.06.007
[7]  Bitar, D., Demarco, T. and Martin, P.O. (2005) Steel and Non Composite Cellular Beams—Novel Approach for Design Based on Experimental Studies and Numerical Investigations. EUROSTEEL.
[8]  Nadjai, A. (2005) Performance of Cellular Composite Floor Beams at Ambient Temperatures. FireSERT, Test Report.
[9]  Nadjai, A., Vassart, O., Ali, F., Talamona, D., Allam, A. and Hawes, M. (2007) Performance of Cellular Composite Floor Beams at Elevated Temperatures. Fire Safety Journal, 42, 489-497.
https://doi.org/10.1016/j.firesaf.2007.05.001
[10]  Vassart, O., Bailey, C.G., Bihina, G., Hawes, M., Nadjai, A., Peigneux, C., Simms, W.I. and Franssen, J.M. (2010) Parametrical Study on the Behaviour of Steel and Composite Cellular Beams under Fire Conditions. Proceedings of the Sixth International Conference on Structures in Fire (SiF’10), East Lansing, 2-4 January 2010, 349-357.
[11]  Bihina, G., Zhao, B. and Vassart, O. (2009) Cellular Composite Beams at Elevated Temperatures, Experimental Investigation. Proceedings of International Conference Prague, Prague, 19-20 April 2013, 537-542.
[12]  Vassart, O., Bailey, C.G., Hawes, M., Nadjai, A., Simms, W.I., Zhao, B., Gernay, T. and Franssen, J.M. (2010) Large-Scale Fire Test of Unprotected Cellular Beam Acting in Membrane Action. Journal of Structural Fire Engineering, 2, 259-268.
https://doi.org/10.1260/2040-2317.2.4.259
[13]  EC3, ENV 1993-1-1 (2005) Eurocode 3: Design of Steel Structures. Part 1-1: General Rules and Rules for Buildings. Annex N. European Committee for Standardization.
[14]  Cong, S., Liang, S. and Dong, Y. (2005) Experimental Investigation of Behavior of Simple Supported Steel Beams under Fire. Journal of Southeast University (Natural Science Edition), 35, 66-68.
[15]  EN 1994-1-2 (2005) Eurocode 4: Design of Composite Steel and Concrete Structures. Part 1-2: General rules. Structural Fire Design. European Committee for Standardization (CEN).
[16]  EN 1991-1-2 (2003) Eurocode 1: Actions on Structures. Part 1-2: General Actions. Actions on Structures Exposed to Fire. European Committee for Standardization (CEN).
[17]  EN 1993-1-2 (2005) Eurocode 3: Design of Steel Structures. Part 1-2: General Rules. Structural Fire Design. European Committee for Standardization (CEN)
[18]  ABAQUS/Standard Version 6.12, Dassault Systèmes, Providence, RI, USA.

Full-Text