基于广州北部地区配电线路故障跳闸原因分析及对策的研究
|
Abstract:
为提高广州北部地区配电线路供电可靠性,通过分析总结广州市从化区配电线路的运行情况,系统介绍了从化区10 kV配电线路常见的故障跳闸类型,重点分析了温泉供电所配电网的基本情况和故障跳闸成因等内容。同时,结合10 kV配电线路日常工作的运维经验和现有国内主要研究资料,找准配电线路故障跳闸急需解决的主要问题,制定了符合研究区域实际情况的改善10 kV配电线路故障跳闸率措施和方法。尤其是研制和应用了一种架空线路快速移动小物体探测驱赶装置,通过一整年的时间对照主要问题逐一落实整改措施,并最终取得了一定成效。2022年度研究区域的中压线路故障跳闸率和客户平均停电时间大幅降低。另外,针对实施措施过程中暴露的问题和不足提出了后续整改提升建议。
To improve the reliability of distribution lines in the northern part of the Guang-zhou Area, the operation of distribution lines in the Conghua District of Guangzhou City was analyzed and summarized, the common fault trip types of 10kV distribution lines in Conghua District are introduced systematically, the basic situation of distribution network and the cause of fault trip in Wenquan Power supply station are emphatically analyzed. At the same time, combined with the daily operation experience and the existing domestic main research data of 10 kV distribution lines, find out the main problems that need to be solved urgently, the measures and methods to improve the failure trip rate of 10 kV distribution lines according to the actual conditions of the study area are formulated. In particular, a device for detecting and driving small fast-moving objects on over-head lines has been developed and applied, through a whole year against the main problems one by one to implement rectification measures, and finally achieved some results. In 2022, the failure trip rate of medium voltage lines and the average power cut time of customers in the study area have been greatly reduced. In addition, this article proposes suggestions for subsequent rectification and improvement in response to the problems exposed during the implementation of measures.
[1] | 田涛. 10 KV线路故障原因及预防措施[J]. 中国集体经济, 2011(31): 175. |
[2] | 李明水. 配电网故障分析及管控[J]. 自动化应用, 2017(8): 107, 141. |
[3] | 张红. 农村配电线路除树障面临问题及对策探析[J]. 现代国企研究, 2015(22): 184-185. |
[4] | 汪继刚, 汤勇. 外力破坏引起配电线路跳闸的分析及防范措施[J]. 农电管理, 2017(9): 38-39. |
[5] | 方英其. 10 kV配电线路故障跳闸原因及解决措施[J]. 低碳世界, 2017(33): 164-165. |
[6] | 马伟东. 10 kV农村配电线路故障跳闸率的降低措施[J]. 现代工业经济和信息化, 2021, 11(12): 230-231. |
[7] | 安畅. 配电线路故障跳闸原因及其对策分析[J]. 科技展望, 2016, 26(29): 97. |
[8] | 彭晓红. 10 kV配电线路故障原因跳闸分析[J]. 通讯世界, 2017(8): 193-194. |
[9] | 刘定坚. 基于龙门地区改善10 kV农村配电线路故障跳闸率的研究[D]: [硕士学位论文]. 广州: 广东工业大学, 2019. |
[10] | 刘鹏祥, 周金萍, 潘颖瑜. 10 kV配网故障停电原因分析及解决对策研究[J]. 中国高新技术企业, 2012(26): 85-86. |
[11] | 周庆春. 关于配电线路故障问题的思考[J]. 低碳世界, 2017(20): 75-76. |