应用于恶臭气体稀释嗅辨新型文丘里管设计及优化
|
Abstract:
本文设计了一种新型的文丘里管,以套管结构代替渐扩管段,增加气体的动能传递效率,目的是解决异味评价中测试仪器气体稀释范围、稀释精度、混合效率等问题。CFD实验对径向流量及截面浓度分布模拟,结果表明进气口压力条件与出口体积流量具有良好的线性关系,决定系数R2为0.992,当相对压力为150 kPa时,能很好满足出口体积流量20 L/min的要求。以正丁醇(n-butanol)为模拟过程的标准气体,测试点位浓度均值为0.2673 ppm,不均匀度Sd为0.127,当Sd < 0.20时,表明通过出口截面正丁醇浓度分布均匀。根据EN-13725进行实验验证,在满足t分布的95%置信区间即δw,d取值为(?0.0541, 0.0431)时,计算精度Ad为0.108,满足Ad取值不超过0.20的要求,测试精度与设计值吻合。
In this paper, a new venturi with a casing structure rather than a tapering section is designed to increase the kinetic energy transfer efficiency of the gas, with the goal of solving the problems of gas dilution range, dilution accuracy, and mixing efficiency of the test instrument in odor evaluation. CFD simulations of the radial flow rate and cross-sectional concentration distribu-tion show that the inlet pressure condition has a good linear relationship with the outlet volume flow rate, and the decision coefficient R2 is 0.992, and when the relative pressure is 150 kPa, it can well meet the requirement of 20L/min. The mean concentration at the test point is 0.2673 ppm with n-butanol as the standard gas for the simulated process, and the inhomogeneity Sd is 0.127. When Sd = 0.20, it means that the n-butanol concentration is distributed uniformly through the out-flow portion. When the 95% confidence interval of the t-distribution is satisfied, i.e. δw,d is taken as (?0.0541, 0.0431), the estimated accuracy Ad is 0.108, which meets the condition of Ad not exceeding 0.20, and the test accuracy equals the design value, according to EN-13725.
[1] | 朱中杨, 颜玉玺, 金博强, 等. 国内外恶臭污染排放法规的进展[J]. 应用化工, 2021, 50(8): 2194-2199. |
[2] | 赵鹏, 刘杰民, 伊芹, 等. 异味污染评价与治理研究进展 [J]. 环境化学, 2011, 30(1): 310-325. |
[3] | Capelli, L., Sironi, S., Del Rosso, R., Céntola, P. and Grande, M. (2008) A Comparative and Critical Evaluation of Odour Assessment Methods on a Landfill Site. Atmospheric Environment, 42, 7050-7058.
https://doi.org/10.1016/j.atmosenv.2008.06.009 |
[4] | Hemeon, W.C.L. (1968) Technique and Apparatus For Quan-titative Measurement of Odor Emissions. Journal of the Air Pollution Control Association, 18, 166-170.
https://doi.org/10.1080/00022470.1968.10469111 |
[5] | Topper, P.A., Graves, R.E., Bruns, M.A., Wysocki, C.J. and Wheeler, E.F. (2007) Odor-Reduction Performance of Constructed Wetland Treating Diluted Swine Manure. Applied Engineering in Agriculture, 23, 621-630.
https://doi.org/10.13031/2013.23671 |
[6] | Nicolai, R.E., Larson, V.J. and Clanton, C.J. (1999) Dynamicol Fac-tometer Airflow Variation in Determining Odor Dilutions-to-Threshold. Transactions of the American Society of Agri-cultural Engineers, 1847-1852. |
[7] | Tukimin, A., Zuber, M. and Ahmad, K.-A. (2016) CFD Analysis of Flow through Venturi tube And Its Discharge Coefficient. IOP Conference Series: Materials Science and Engineering, 152, Article ID: 012062.
https://doi.org/10.1088/1757-899X/152/1/012062 |
[8] | Danardono, D., Kim, K.-S., Lee, S.-Y. and Lee, J.-H. (2011) Optimization the Design of Venturi Gas Mixer for Syngas engine Using Three-Dimensional CFD Modeling. Journal of Mechanical Science and Technology, 25, 2285-2296..
https://doi.org/10.1007/s12206-011-0612-8 |
[9] | Sundararaj, S. and Selladurai, V. (2013) Flow and Mixing Pattern of Transverse Turbulent Jet in Venturi-Jet Mixer. Arabian Journal for Science and Engineering, 38, 3563-3573. https://doi.org/10.1007/s13369-013-0643-9 |
[10] | Naganuma, T., Sakonji, T. and Shoji, F. (1992) New Gas Mixer for Gas Engines—Optimized Air-Fuel Ratio with Negligible Pressure Loss. SAE Technical Paper No. 922361. https://doi.org/10.4271/922361 |
[11] | Sundararaj, S. and Selladurai, V. (2010) Numerical and Experimental Study on Jet Trajectories and Mixing Behavior of Venturi-Jet Mixer. Journal of Fluids Engineering, 132, Article ID: 101104. https://doi.org/10.1115/1.4002575 |
[12] | Aoki, N. and Mae, K. (2006) Effects of Channel Geometry on Mixing Per-formance of Micromixers Using Collision of Fluid Segments. Chemical Engineering Journal, 118, 189-197. https://doi.org/10.1016/j.cej.2006.02.011 |
[13] | Suffet, I.H. and Rosenfeld, P. (2007) The Anatomy of Odour Wheels for Odours of Drinking Water, Wastewater, Compost and the Urban Environment. Water Science and Technolo-gy, 55, 335-344.
https://doi.org/10.2166/wst.2007.196 |
[14] | Ghassemi, H. and Fasih, H.F. (2011) Application of Small Size Cavitat-ing Venturi as Flow Controller and Flow Meter. Flow Measurement and Instrumentation, 22, 406-412. https://doi.org/10.1016/j.flowmeasinst.2011.05.001 |
[15] | Blacker, J.H. and Brief, R.S. (1971) A Dilution System for Dynamic Preparation of Gas Concentrations. American Industrial Hygiene Association Journal, 32, 668-672. https://doi.org/10.1080/0002889718506522 |
[16] | Ulas, A. (2006) Passive Flow Control in Liquid-Propellant Rock-et Engines with Cavitating Venturi. Flow Measurement and Instrumentation, 17, 93-97. https://doi.org/10.1016/j.flowmeasinst.2005.10.003 |
[17] | Luo, P., Cheng, Y., Zhao, Y., Jin, Y. and Yang, W. (2007) Millisecond Mixing of Two Liquid Streams in a Mixer Model. Chemical Engineering Science, 62, 5688-5695. https://doi.org/10.1016/j.ces.2007.02.038 |
[18] | Charbel, H., Thierry, L., Dominique, D. and Hassan, P. (2010) Turbulent Mixing and Residence Time Distribution in Novel Multifunctional Heat Exchangers-Reactors. Chemical Engi-neering and Processing: Process Intensification, 49, 1066-1075. https://doi.org/10.1016/j.cep.2010.08.007 |
[19] | Fu, D. (2004) Study on the Phase Equilibria of Hard Core Asakura-Oosawa Fluids with Renormalization—Group Theory. Department of Environmental Engineering. |
[20] | M Sallaberger, PDrtina. (1999) Hydraulic Turbines—Basic Principles and State-of-Theart Computational Fluid Dynamics Applications. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 213, 1-2. https://doi.org/10.1243/0954406991522202 |
[21] | Shawn, D.B., Mia, W., Michael, G., Thomas, P.E. and Matt, W. (2019) A Novel Olfactometer for Efficient and Flexible Odorant Delivery. Chemical Senses, 44, 173-188. https://doi.org/10.1093/chemse/bjz005 |
[22] | Utomo, T., Jin, Z., Rahman, M., Jeong, H. and Chung, H. (2008) In-vestigation on Hydrodynamics and Mass Transfer Characteristics of a Gas-Liquid Ejector Using Three-Dimensional CFD Modeling. Journal of Mechanical Science and Technology, 22, 1821-1829. https://doi.org/10.1007/s12206-008-0614-3 |
[23] | ISO 16000-28: 2012 Indoor Air Part 28: Determination of Odour Emissions from Building Products Using Test Chambers. ISO. |
[24] | Patsa, C.-M., Sch?nfeld, F. and Mouza, A.A. (2008) Mixing Performance of a Chaotic Micro-Mixer. Chemical Engineering Research and Design, 86, 1128-1134. https://doi.org/10.1016/j.cherd.2008.04.009 |
[25] | ISO-5725-4 (2020) Accuracy (Tureness and Precision) of Meas-urement Methods and Results. ISO. |
[26] | BS-EN-13725 (2003) Air Quality—Determination of Odour Concentration by Dynamic Olfactometry. British Standard. |
[27] | Charles, M. and McGinley, P.E. (2002) Standardized Odor Measurement Practices for Air Quality Testing. Air and Waste Management Association Symposium on Air Quality Measurement Methods and Technology—2002, San Francisco, 13-15 November, 2002, 1-2. |
[28] | Gonzalez-Trejo, J., Real-Ramirez, C.A., Miranda-Tello, R., et al. (2017) Numerical and Physical Parametric Analysis of a SEN with Flow Conditioners in Slab Continuous Casting Mold. Archives of Metallurgy and Materials, 62, 927-946. https://doi.org/10.1515/amm-2017-0136 |
[29] | ISO 5167-1 (2022) Measurement of Fluid Flow by Means of Pres-sure Differential Devices Inserted in Circular Cross-Section Conduits Running Full—Part 1: General Principles and Re-quirements. ISO. |
[30] | 曹德嘉. 流动调整器在设冷水流量测量改进中的应用[J]. 价值工程, 2017, 36(34): 174-175. |