连接闪烁屏和光电传感器的间隙材料对探测器性能影响研究
Study on the Influence of Gap Material Connecting Scintillation Screen and Photoelectric Sensor on Detector Performance

DOI: 10.12677/APP.2022.1211068, PP. 584-592

Keywords: X射线探测器,间隙材料,光输出,调制传递函数
X-Ray Detector
, Gap Material, Light Output, Modulation Transfer Function

Full-Text   Cite this paper   Add to My Lib

Abstract:

间接式X射线探测器中闪烁屏和光电传感器的直接连接一般有压制和耦合两种工艺,其间隙材料可分别为空气和硅油。本文基于Geant4工具包建立微通道阵列式CsI:Tl闪烁体探测器模型,讨论两种间隙材料及其厚度对探测器光输出和调制传递函数的影响。给出了探测器在两种材料条件下的光输出,以及不同材料厚度下的空间分辨率。结果对后续的探测器性能评估具有重要意义。
The direct connection between the scintillation screen and the photoelectric sensor in the indirect X-ray detector generally has two processes: pressing and coupling, and the gap materials can be air and silicone oil, respectively. In this paper, a microchannel array CsI:Tl scintillator detector model is established based on the Geant4 toolkit, and the effects of two gap materials and their thicknesses on the light output and the modulation transfer function of the detector are discussed. The light output of the detector under the conditions of two materials and the spatial resolution under different material thicknesses are given. The results are of great significance for subsequent detector performance evaluation.

References

[1]  龚建伟, 陈兵. 间接式X射线探测器的核心器件及其耦合方式[J]. 激光与光电子学进展, 2022, 59(7): 37-52.
[2]  Nagarkar, V.V., Gupta, T.K., Miller, S.R., et al. (1998) Structured CsI(Tl) Scintillators for X-Ray Imaging Applications. IEEE Transactions on Nuclear Science, 45, 492-496.
https://doi.org/10.1109/23.682433
[3]  Fujieda, I. and Cho, G. (1991) X-Ray and Charged Particle Detection with CsI(Tl) Layer Coupled to a Si:H Photodiode Layers. IEEE Transactions on Nuclear Science, 38, 255-262.
https://doi.org/10.1109/23.289306
[4]  Jing, T., Goodman, C.A., Drewery, J., et al. (1994) Amorphous Silicon Pixel Layers with Cesium Iodide Converters for Medical Radiography. IEEE Transactions on Nuclear Science, 41, 903-909.
https://doi.org/10.1109/23.322829
[5]  Svenonius, O., Sahlholm, A., Wiklund, P. and Linnros, J. (2009) Performance of an X-Ray Imaging Detector Based on a Structured Scintillator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 607, 138-140.
https://doi.org/10.1016/j.nima.2009.03.146
[6]  Allison, J., Amako, K., Apostolakis, J., et al. (2006) Geant4 Developments and Applications. IEEE Transactions on Nuclear Science, 53, 270-278.
[7]  梁波. 基于CsI(Tl)X射线探测器集成化的关键技术研究[D]: [硕士学位论文]. 成都: 电子科技大学, 2016.
[8]  Star-Lack, J., Sun M.S., Meyer, A., et al. (2014) Rapid Monte Carlo Simulation of Detector DQE(f). Medical Physics, 41, 031916.
https://doi.org/10.1118/1.4865761
[9]  Lecoq, P. (2016) Development of New Scintillators for Medical Ap-plications. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 809, 130-139.
https://doi.org/10.1016/j.nima.2015.08.041
[10]  Grassmann, H., Lorenz, E. and Moser, H.-G. (1985) Properties of CsI(TI)—Renaissance of an Old Scintillation Material. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 228, 323-326.
https://doi.org/10.1016/0168-9002(85)90276-1
[11]  张红柳. CsI:TI闪烁薄膜的工艺制备和光学特性的研究[D]: [硕士学位论文]. 成都: 电子科技大学, 2015.
[12]  Refractive Index Database. https://refractiveindex.info/

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133