In vitroexperimental set-up is an important tool for investigating abdominal aortic aneurysm (AAA). Accurate reproduction of the physiological pulsatile flow waveform in the abdominal aorta at various anatomic locations is an important component of these experimental methods. The objective of this study is to establish an experimental set-up to generate a physiological pulsatile flow for in vitro simulations of the abdominal aorta. The physiological flow was established by a computer-controlled peristaltic pump and the flow field in a circular straight pipe is measured under pulsatile flow conditions by a 2-dimensional particle image velocimetry system (2D-PIV). Experimental results show that the in vitro experimental set-up provides a flow with a period of 2s, a reasonable cross-sectional velocity distribution and an approximate inlet velocity profile that is close to the human abdominal aorta.
References
[1]
Santilli, J.D. and Santilli, S.M. (1997) Diagnosis and Treatment of Abdominal Aortic Aneurysms. American Family Physician, 56, 1081-1090.
[2]
Sampson, U.K., Norman, P.E., Fowkes, F.G.R., Aboyans, V., Song, Y., Harrell Jr., F.E. and Murray, C. (2014) Estimation of Global and Regional Incidence and Prevalence of Abdominal Aortic Aneurysms 1990 to 2010. Global Heart, 9, 159-170.
https://doi.org/10.1016/j.gheart.2013.12.009
[3]
Wilmink, T.B., Quick, C.R., Hubbard, C.S. and Day, N.E. (1999) The Influence of Screening on the Incidence of Ruptured Abdominal Aortic Aneurysms. Journal of Vascular Surgery, 30, 203-208. https://doi.org/10.1016/S0741-5214(99)70129-1
[4]
Biasetti, J., Hussain, F. and Gasser, T.C. (2011) Blood Flow and Coherent Vortices in the Normal and Aneurysmatic Aortas: A Fluid Dynamical Approach to Intra-Luminal Thrombus Formation. Journal of the Royal Society Interface, 8, 1449-1461. https://doi.org/10.1098/rsif.2011.0041
[5]
Cong, Y., Wang, L. and Liu, X. (2015) A Numerical Study of Fluid-Structure Coupled Effect of Abdominal Aortic Aneurysm. Bio-Medical Materials and Engineering, 26, S245-S255. https://doi.org/10.3233/BME-151311
[6]
Asbury, C.L., Ruberti, J.W., Bluth, E.I. and Peattie, R.A. (1995) Experimental Investigation of Steady Flow in Rigid Models of Abdominal Aortic Aneurysms. Annals of Biomedical Engineering, 23, 29-39. https://doi.org/10.1007/BF02368298
[7]
Antón, R., Chen, C.Y., Hung, M.Y., Finol, E.A. and Pekkan, K. (2015) Experimental and Computational Investigation of the Patient-Specific Abdominal Aortic Aneurysm Pressure Field. Computer Methods in Biomechanics and Biomedical Engineering, 18, 981-992. https://doi.org/10.1080/10255842.2013.865024
[8]
Stamatopoulos, C., Papaharilaou, Y., Mathioulakis, D.S. and Katsamouris, A. (2010) Steady and Unsteady Flow within an Axisymmetric Tube Dilatation. Experimental Thermal and Fluid Science, 34, 915-927.
https://doi.org/10.1016/j.expthermflusci.2010.02.008
[9]
Moore, J.E., Ku, D.N., Zarins, C.K. and Glagov, S. (1992) Pulsatile Flow Visualization in the Abdominal Aorta under Differing Physiologic Conditions: Implications for Increased Susceptibility to Atherosclerosis. Journal of Biomechanical Engineering, 114, 391-397. https://doi.org/10.1115/1.2891400
[10]
Peattie, R.A., Riehle, T.J. and Bluth, E.I. (2004) Pulsatile Flow in Fusiform Models of Ab dominal Aortic Aneurysms: Flow Fields, Velocity Patterns and Flow-Induced Wall Stresses. Journal of Biomechanical Engineering, 126, 438-446.
https://doi.org/10.1115/1.1784478
[11]
Tsai, W. and Savas, O. (2010) Flow Pumping System for Physiological Waveforms. Medical & Biological Engineering & Computing, 48, 197-201.
https://doi.org/10.1007/s11517-009-0573-6
[12]
Deplano, V., Knapp, Y., Bailly, L. and Bertrand, E. (2014) Flow of A Blood Analogue Fluid in A Compliant Abdominal Aortic Aneurysm Model: Experimental Modelling. Journal of Biomechanics, 47, 1262-1269.
https://doi.org/10.1016/j.jbiomech.2014.02.026
[13]
Mechoor, R.R., Schmidt, T. and Kung, E. (2016) A Real-Time Programmable Pulsatile Flow Pump for in Vitro Cardiovascular Experimentation. Journal of Biomechanical Engineering, 138, Article ID: 111002. https://doi.org/10.1115/1.4034561
[14]
Roloff, C., Stucht, D., Beuing, O. and Berg, P. (2019) Comparison of Intracranial Aneurysm Flow Quantification Techniques: Standard PIVvs Stereoscopic PIVvs Tomographic PIVvs Phase-Contrast MRIvs CFD. Journal of Neurointerventional Surgery, 11, 275-282. https://doi.org/10.1136/neurintsurg-2018-013921
[15]
Olufsen, M.S., Peskin, C.S., Kim, W.Y., Pedersen, E.M., Nadim, A. and Larsen, J. (2000) Numerical Simulation and Experimental Validation of Blood flow in Arteries with Structured-Tree Outflow Conditions. Annals of Biomedical Engineering, 28, 1281-1299. https://doi.org/10.1114/1.1326031
[16]
Deplano, V., Guivier-Curien, C. and Bertrand, E. (2016) 3D Analysis of Vortical Structures in an Abdominal Aortic Aneurysm by Stereoscopic PIV. Experiments in Fluids, 57, Article No. 167. https://doi.org/10.1007/s00348-016-2263-0
[17]
Yu, S.C.M. (2000) Steady and Pulsatile Flow Studies in Abdominal Aortic Aneurysm Models Using Particle Image Velocimetry. International Journal of Heat and Fluid Flow, 21, 74-83. https://doi.org/10.1016/S0142-727X(99)00058-2
[18]
Stamatopoulos, C., Mathioulakis, D.S., Papaharilaou, Y. and Katsamouris, A. (2011) Experimental Unsteady Flow Study in a Patient-Specific Abdominal Aortic Aneurysm Model. Experiments in Fluids, 50, 1695-1709.
https://doi.org/10.1007/s00348-010-1034-6
[19]
Wang, Y., Joannic, D., Patrick, J., Keromnes, A., Aurélien, M., Lalande, A. and Fontaine, J.F. (2016) Comparison of Flow Measurement by 4D Flow Magnetic Resonance Imaging and by Particles Image Velocimetry on Phantom of Abdominal Aortic Aneurysm. SM Vascular Medicine, 1, Article No.1008.
[20]
Durst, F., Ray, S., ünsal, B. and Bayoumi, O.A. (2005) The Development Lengths of Laminar Pipe and Channel Flows. Journal of Fluids Engineering, 127, 1154-1160.
https://doi.org/10.1115/1.2063088
[21]
He, X. and Ku, D.N. (1994) Unsteady Entrance Flow Development in a Straight Tube. Journal of Biomechanical Engineering, 116, 355-360.
https://doi.org/10.1115/1.2895742