Comparative Studies of Absolute Dose in Water Phantom, Solid Water Phantom and MatriXX with MULTICube Phantom

DOI: 10.4236/ijmpcero.2021.104014, PP. 169-177

Keywords: Phantom, Quality Assurance, Dosimetry, Absorbed Dose

Full-Text   Cite this paper   Add to My Lib

Abstract:

Introduction: Radiotherapy is one of the important treatment modalities in cancer treatment. To maintain the treatment procedure accuracy, the phantom is an essential tool for absolute dosimetry conformation and Quality Assurance routine cheek up. This work aims to study the absorbed dose of various phantoms and hence to make a comparison of the result with the IAEA recommendation (TRS 398) for daily QA of Linac. Materials and Methods: The experiment has been done at the Institute of Nuclear Medical Physics (INMP), AERE, Savar, Dhaka, under the Bangladesh Atomic Energy Commission. For external beam radiation, 6 MV and 15 MV photon beams of Varian Clinac iX Linear Accelerator (Linac) were used. One dimensional (1D) water phantom, solid water phantom, and MatriXX with MULTICube phantom and associate accessories were used to experiment. Results: We have measured and compared the absorbed dose data of the phantoms. The variation of sold water phantom from the 1D water phantom is +2.8% at 6 MV and +3.5% at 15 MV. The variation MatriXX with MULTIcube phantom from the 1D water phantom is +8.0% at 6 MV and +3.2% at 15 MV. This study revealed that the 1D water phantom was the best absolute dose conformation among the other phantoms and the deviation was within the acceptable limit (±5%), except MatriXX with MULTICube Phantom for low energy beam (8%). Conclusion: It was observed that the accuracy of dose estimation was better in the 1D water phantom rather than the other two. It is also known that the 1D water phantom is low cost but needs a long time to set up for the experimental arrangement. Solid water or MatriXX with MULTICube phantom can be used to overcome this problem, which takes only a few minutes for setup and is comparatively faster than 1D water phantom.

References

[1]  Christophorou, L.G., Anderson, V.E. and Birks, J.B. (1971) Atomic and Molecular Radiation Physics. Wiley-Interscience, New York.
[2]  Blackadar, C.B. (2016) Historical Review of the Causes of Cancer. World Journal of Clinical Oncology, 7, 54-86.
https://doi.org/10.5306/wjco.v7.i1.54
[3]  Mettler, F.A. and Guiberteau, M.J. (2012) Essentials of Nuclear Medicine Imaging: Expert Consult-Online and Print. Elsevier Health Sciences, Amsterdam.
[4]  Segawa, Y., Takigawa, N., Kataoka, M., Takata, I., Fujimoto, N. and Ueoka, H. (1997) Risk Factors for Development of Radiation Pneumonitis Following Radiation Therapy with or without Chemotherapy for Lung Cancer. International Journal of Radiation Oncology, Biology, Physics, 39, 91-98.
https://doi.org/10.1016/S0360-3016(97)00297-6
[5]  Lee, C.G. (2004) High Precision Radiotherapy. Journal of the Korean Medical Association, 47, 663-671.
https://doi.org/10.5124/jkma.2004.47.7.663
[6]  Khan, F.M. and Gibbons, J.P. (2014) The Physics of Radiation Therapy. Lippincott Williams & Wilkins.
[7]  Gossman, M.S. and Bank, M.I. (2010) Dose-Volume Histogram Quality Assurance for Linac-Based Treatment Planning Systems. Journal of Medical Physics, 35, 197-201.
https://doi.org/10.4103/0971-6203.71759
[8]  Chen, G.P., Ahunbay, E. and Li, X.A. (2016) Development and Performance of a Software Tool for Quality Assurance of Online Replanning with a Conventional Linac or MR-Linac. Medical Physics, 43, 1713-1719.
https://doi.org/10.1118/1.4943795
[9]  Fuse, H., Fujisaki, T., Ikeda, R. and Hakani, Z. (2018) Applicability of Lung Equivalent Phantom Using the Cork with Absorbed Water in Radiotherapeutic Dosimetry. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 7, 27-34.
https://doi.org/10.4236/ijmpcero.2018.71003
[10]  Hong, J.W., Lee, H.K. and Cho, J.H. (2015) Comparison of the Photon Charge between Water and Solid Phantom Depending on Depth. International Journal of Radiation Research, 13, 229-234.
[11]  Rahman, M.A., Bhuiyan, T.H., Rahman, M.M. and Chowdhury, M.N. (2018) Comparative Study of Absorbed Doses in Different Phantom Materials and Fabrication of a Suitable Phantom. Malaysian Journal of Medical and Biological Research, 5, 19-24.
[12]  Thwaites, D.I. (1985) Measurements of Ionization in Water, Polystyrene and a ‘Solid Water’ Phantom Material for Electron Beams. Physics in Medicine & Biology, 30, 41-53.
https://doi.org/10.1088/0031-9155/30/1/005
[13]  Kim, J.E, Cha, B.Y., Kang, S.S., Park, J.K., Sin, J.W., Kim, S.Y., Jo, S.H., Son, D.W., Choi, C.W., Park, C.H., Yoon, C.H., Lee, J.D., Park, B.D. and Nam, S.H. (2008) 10 MV X-Ray Beam Dosimetry by Water and White Polystyrene Phantom. Journal of Radiological Science and Technology, 31, 83-87
[14]  Choi, C.H., Kim, J.I., Park, J.M., Park, Y.K., Ye, S.J., Cho, K.W., Cho, W.K. and Lim, C.I. (2010) External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities. Journal of the Korean Society for Therapeutic Radiology and Oncology, 28, 50-56.
https://doi.org/10.3857/jkstro.2010.28.1.50
[15]  Seuntjens, J., Olivares, M., Evans, M. and Podgorsak, E. (2005) Absorbed Dose to Water Reference Dosimetry Using Solid Phantoms in the Context of Absorbed-Dose Protocols. Medical Physics, 32, 2945-2953.
https://doi.org/10.1118/1.2012807
[16]  Zhu, D., Austerlitz, C., Benhabib, S., Mota, H., Allison, R.R. and Campos, D. (2010) Study of a Spherical Phantom for Gamma Knife Dosimetry. Journal of Applied Clinical Medical Physics, 11, 222-229.
https://doi.org/10.1120/jacmp.v11i2.3130
[17]  Constantinou, C., Attix, F.H. and Paliwal, B.R. (1982) A Solid Water Phantom Material for Radiotherapy X-Ray and γ-Ray Beam Calibrations. Medical Physics, 9, 436-441.
https://doi.org/10.1118/1.595063
[18]  Borcia, C. and Mihailescu, D. (2008) Are Water-Equivalent Materials Used in Electron Beams Dosimetry Really Water Equivalent? Romanian Journal of Physics, 53, 851-863.
[19]  International Atomic Energy Agency (2000) Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, Technical Reports Series No. 398. IAEA, Vienna.
[20]  Huang, J.C. and Reinstein, L.E. (2000) Evaluation of an Innovative Plastic Cube Phantom Designed to Improve the Efficiency of Accelerator QA. Journal of Applied Clinical Medical Physics, 1, 153-157.
https://doi.org/10.1120/jacmp.v1i4.2637
[21]  Thomadsen, B., Constantinou, C. and Ho, A. (1995) Evaluation of Water-Equivalent Plastics as Phantom Material for Electron-Beam Dosimetry. Medical Physics, 22, 291-296.
https://doi.org/10.1118/1.597453

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133