In this work, a 532 nm diode CW laser is used to heat samples used as building materials at a 1 meter standoff distance while using an FLIR (Forward-Looking Infrared) thermal camera to monitor and record the heating and then cooling of each sample after lasers are switched off. The data is then analyzed using FLIR proprietary software. Since the absorption spectra of materials are unique, using multiple lasers of different wavelengths to simultaneously shine onto the sample at different locations would give enough thermal data to successfully characterize the samples within a reasonable amount of time. The results are very promising for applications involving non-destructive detection and classification of materials.
References
[1]
Albatici, R., Tonelli, A.M. and Chiogna, M. (2015) A Comprehensive Experimental Approach for the Validation of Quantitative Infrared Thermography in the Evaluation of Building Thermal Transmittance. Applied Energy, 141, 218-228. https://doi.org/10.1016/j.apenergy.2014.12.035
[2]
Fokaides, P.A. and Kalogirou, S.A. (2011) Application of Infrared Thermography for the Determination of the Overall Heat Transfer Coefficient (U-Value) in Building Envelopes. Applied Energy, 88, 4358-4365. https://doi.org/10.1016/j.apenergy.2011.05.014
[3]
González-Aguilera, D., Lagüelab, S., Rodríguez-Gonzálveza, P. and Hernández-López, D. (2013) Image-Based Thermographic Modeling for Assessing Energy Efficiency of Buildings Facades. Energy and Buildings, 65, 29-36. https://doi.org/10.1016/j.enbuild.2013.05.040
[4]
Nardi, I., Paoletti, D., Ambrosini, D., de Rubeis, T. and Sfarra, S. (2016) U-Value Assessment by Infrared Thermography: A Comparison of Different Calculation Methods in a Guarded Hot Box. Energy and Buildings, 122, 211-221. https://doi.org/10.1016/j.enbuild.2016.04.017
[5]
Ficco, G., Iannetta, F., Ianniello, E., Alfano, F.R.D. and Dell’Isola, M. (2015) U-Value in Situ Measurement for Energy Diagnosis of Existing Buildings. Energy and Buildings, 104, 108-121. https://doi.org/10.1016/j.enbuild.2015.06.071
[6]
Taylor, T., Counsell, J. and Gill, S. (2013) Energy Efficiency Is More than Skin Deep: Improving Construction Quality Control in New-Build Housing Using Thermography. Energy and Buildings, 66, 222-231. https://doi.org/10.1016/j.enbuild.2013.07.051
[7]
Maroy, K., Carbonez, K., Steeman, M. and Van Den Bossche, N. (2017) Assessing the Thermal Performance of Insulating Glass Units Withinfrared Thermography: Potential and Limitations. Energy and Buildings, 138, 175-192. https://doi.org/10.1016/j.enbuild.2016.10.054
[8]
Tran, Q.H., Han, D., Kang, C., Haldar, A. and Huh, J. (2017) Effects of Ambient Temperature and Relative Humidity on Subsurface Defect Detection in Concrete Structures by Active Thermal Imaging. Sensors, 17, 1718. https://doi.org/10.3390/s17081718
[9]
Bisegna, F., Ambrosini, D., Paoletti, D., Sfarra, S. and Gugliermetti, F. (2014) A Qualitative Method for Combining Thermal Imprints to Emerging Weak Points of Ancient Wall Structures by Passive Infrared Thermography—A Case Study. Journal of Cultural Heritage, 15, 199-202. https://doi.org/10.1016/j.culher.2013.03.006
[10]
Barreira, E., Almeida, R.M.S.F. and Moreira, M. (2017) An Infrared Thermography Passive Approach to Assess the Effect of Leakage Points in Buildings. Energy and Buildings, 140, 224-235. https://doi.org/10.1016/j.enbuild.2017.02.009
[11]
López, G., Basterra, L.A. and Acuña, L. (2013) Estimation of Wood Density Using Infrared Thermography. Construction and Building Materials, 42, 29-32. https://doi.org/10.1016/j.conbuildmat.2013.01.001
[12]
Lehmann, B., Wakili, K.G., Frank, Th., Collado, B.V. and Tanner, Ch. (2013) Effects of Individual Climatic Parameters on the Infrared Thermography of Buildings. Applied Energy, 110, 29-43. https://doi.org/10.1016/j.apenergy.2013.03.066
[13]
Barreira, E. and de Freitas, V.P. (2007) Evaluation of Building Materials Using Infrared Thermography. Construction and Building Materials, 21, 218-224. https://doi.org/10.1016/j.conbuildmat.2005.06.049
[14]
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J. and Bulnes, F.G. (2014) Infrared Thermography for Temperature Measurement and Non-Destructive Testing. Sensors, 14, 12305-12348. https://doi.org/10.3390/s140712305
[15]
Avdelidis, N.P. and Moropoulou, A. (2004) Applications of Infrared Thermography for the Investigation of Historic Structures. Journal of Cultural Heritage, 5, 119-127. https://doi.org/10.1016/j.culher.2003.07.002
[16]
Kordatos, E.Z., Exarchos, D.A., Stavrakos, C., Moropoulou, A. and Matikas, T.E. (2013) Infrared Thermographic Inspection of Murals and Characterization of Degradation in Historic Monuments. Construction and Building Materials, 48, 1261-1265. https://doi.org/10.1016/j.conbuildmat.2012.06.062
[17]
Paoletti, D., Ambrosini, D., Sfarra, S. and Bisegna, F. (2013) Preventive Thermographic Diagnosis of Historical Buildings for Consolidation. Journal of Cultural Heritage, 14, 116-121. https://doi.org/10.1016/j.culher.2012.05.005
[18]
Marrocchino, E., Telloli, C., Aprile, A., Capuani, D., Malaguti, D. and Vaccaro, C. (2021) Case Study on the Mineralogical and Petrophysical Analysis of Reinforced Concrete Slabs of a Highway Viaduct of the S.G.C. Orte-Ravenna. SN Applied Sciences, 3, 623. https://doi.org/10.1007/s42452-021-04620-6
[19]
Garrido, I., Lagűela, S., Otero, R. and Arias, P. (2020) Thermographic Methodologies Used in Infrastructure Inspection: A Review Post-Processing Procedures. Applied Energy, 266, Article ID: 114857. https://doi.org/10.1016/j.apenergy.2020.114857