Objective: The aim of our work is to study radiological practices in C?te d’Ivoire regarding the examination of the frontal chest in order to optimize the dose received by patients. Materials and Methods: The work was carried out in 11 of the most frequented radiology centers and involved 330 patients. The equipment used in addition to those that can be found in an X-ray room is the DAP-meter. Using the DAP-meter, we measured the Dose in the air (Dair) then we calculated the Entrance Surface Dose (De). Results: We have by the statistical method of the 75th percentile determined the Diagnostic Reference Level (DRL): 0.28 ± 0.03 mGy and by the arithmetic average, the average of the entrance surface dose (Dem): 0.23 ± 0.03 mGy. Since the DRL is lower than the Dem, the dose is said to be optimized. However by comparing the DRL of our work to the DRL values obtained in other countries, we can say that efforts can be made to further protect patients from unnecessary doses. This involves increasing the voltage, decreasing the load, increasing the detector focal point distance, and increasing additional filtration.
References
[1]
Organisation Mondiale de la Santé (OMS) (2016) Rayonnements ionisants, effets sur la santé etmesures de protection. Aide-mémoire nº 371, Mai.
[2]
IRSN PRP-HOM/2014-006 France (2012) Exposition de la population française aux rayonnements ionisants liés aux actes du diagnostic médical.
[3]
Pr André Bonnin, Apropos de l’irradiation médicale et de la directive 97/43Européenne Euratom du 30 juin 1997. Le manipulateur d’imagerie médicale et de radiothérapie nº special Septembre 1999.
[4]
Commission Internationale de Protection Radiologique (CIPR) (2007) Publication 103.
[5]
Jean Luc, R. and Patrice, R. (2010) Unité d’expertise en radioprotection médicale. Les Niveaux de Référence Diagnostiques en radiologie. Module National d’enseignement de radioprotection.
[6]
International Commission on Radiological Protection (1996) Radiological and Safety in Medecine. Publication 73, Annals of the ICRP Vol. 26/2, Pergamon Press, Oxford.
[7]
Monnehan, G., Anouan, K., Onoma, D., Yao, K., Kouadio, D., Koua, A. and Dali, P. (2009) Détermination des niveaux de référence diagnostiques en Côte d’Ivoire: Cas de la radiographie du thorax de face et de l’abdomen sans préparation (ASP) de face chez l’adulte dans le district d’Abidjan et dans la région du Sud Comoé. Revue Ivoirienne de Science et Technologie, 14.
[8]
Konaté, I., et al. (2019) Diagnostic Reference Level in Frontal Chest X-Ray in Western Cote d’Ivoire. World Journal of Nuclear Science and Technology, 9, 147-158.
https://doi.org/10.4236/wjnst.2019.94011
[9]
Journal Officiel, Article 4D 497 du Décret nº67-321 du 21 juillet 1967, portant codification des dispositions règlementaires prises pour application du titre VI hygiène et securité_service médical de la loi nº 64-290 du 1er Aout 1964, portant code du travail 9 juillet 1968.
[10]
IRSN PRP-HOM/2014-9, Analyse des données relatives à la mise à jour des niveaux de référence diagnostiques en radiologie et en médecine nucléaire. Bilan 2011-2012.
[11]
PTW. User Manual Diasoft Version 5.2. D154.131.O/7 2004-03 Md/Hn.
[12]
Leclet, H. (2021) Président de la commission de normalisation AFNOR. La métrologie des niveaux de dose dans les pratiques radiodiagnostiques.
http://www.bivi.metrologie.afnor.org
[13]
(2016) Glossaire-Statistica, Centile.
[14]
Mazerolle, F. (2012) Moyenne arithmétique.
[15]
Cordoliani, Y.-S. and Foehrenbach, H. (2014) Radioprotection en milieu médical. Principes et mise en pratique 3eme édition.
[16]
European Commission (EC) (2014) Diagnostic Reference Levels in Thirsty-Six European Countries Part 2/2. Radiation Protection nº180.
[17]
Hart, D., Hillier, M.C. and Shrimpton, P.C. (2012) Doses to Patients from, Radiographic and Fluoroscopic X-Ray Imaging Procedures in the UK-2010. HPA-CRCE-034.
[18]
Homolka, P. (2009) Center for Biomedical Engineering and Physics Medical University of Vienna, Austria, IAEA. Diagnostic Reference Levels (Guidance Levels). IAEA Training Course on Medical Physics in Diagnostic Radiology. Trieste, Italy May 11-15 2009.
[19]
IRSN France PRP-HOM/2012-12. Analyse des données relatives à la mise à jour des niveaux de référence diagnostiques en radiologie et en médecine nucléaire. Bilan 2009-2010.
[20]
Odette, N., Jean, Y., Roméo, T., Alain, G. and Fai, C. (2015) Niveaux de référence diagnostiques en radiographie thoracique à Yaoundé. Journal Africain de l’imagerie Médicale, 3, 152-162.
[21]
Suliman, I.I., Abbas, N. and Habbani, F.I. (2007) Entrance Surface Doses to Patients Undergoing Selected Diagnostic X-Ray Examinations in Sudan. Radiation Protection Dosimetry, 123, 209-214. https://doi.org/10.1093/rpd/ncl137
[22]
Obed, R., Ademola, A., Adewoyin, K. and Akunade, O. (2007) Doses to Patients in Routine X-Ray Examinations of Chest, Skull, Abdomen and Pelvis in Nine Selected Hospitals in Nigeria. Research Journal of Medical Sciences, 1, 209-214.
[23]
Muhogora, W., Ahmed, N., Almosabihi, A., Alsuwaidi, J., Beganovic, A., Ciraj-Bjélac, O., Shandorf, C., Rehani, M., Ramanazndraibe, M., Mukwadag, M. and Rouzitalab, J. (2008) Patient Doses in Radiographic Examinations in 12 Countries in Asia, Africa and Eastern Europe: Initial Results from IAEA Projects. American Journal of Roentgenology, 190, 1453-1461. https://doi.org/10.2214/AJR.07.3039
[24]
Société Française de radiologie (SFR) (2014) Guide des procédures radiologiques. Critère de qualité et d’optimisation.
[25]
Foulquier, J.N. (2010) éléments technologiques permettant de réduire la dose en radiologie conventionnelle et numérique. Journal de Radiologie, 91, 1225-1230.
https://doi.org/10.1016/S0221-0363(10)70178-5