Exact Dynamic Modeling of PWM DC-to-DC Power Converters—Part II: Discontinuous Conduction Mode

DOI: 10.4236/jpee.2021.95003, PP. 48-62

Keywords: Describing Function, DC-to-DC Switching Power Converter, Small-Signal Modeling, Frequency Response

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper follows on from the first paper, Part I, where a general formulation of a describing function approach to frequency response determination of switched linear networks, such as PWM converters, was simplified and updated. The models assume a piecewise linear state space equation description of the system and results in a closed form solution for the sought after frequency response. In Part I, model derivation was demonstrated for the case of PWM converters operating in the continuous conduction mode (CCM). This operating mode does not feature any state dependent switching times. In this paper, Part II, frequency response models for any transfer function for PWM converters operating in discontinuous conduction mode (DCM) are derived based on the theory presented in Part I. This operating model features state dependent switching times. The describing function models developed are exact and therefore, in terms of accuracy, are to be preferred over averaged models which are widely used. The example of a boost dc-to-dc converter operating in DCM is simulated to obtain the control to output and input to output frequency responses and are compared with the models derived here. Excellent agreement between the simulated and model responses was found. Matlab code implementing the analytical models is also presented which the user can adapt for any other PWM converter topology. The models derived here may be used as a basis from which simplified models may be derived while still preserving required accuracy.

References

[1]  Tymerski, R. (1991) Frequency Analysis of Time-Interval-Modulated Switched Networks. IEEE Transactions on Power Electronics, 6, 287-295.
https://doi.org/10.1109/63.76815
[2]  Tymerski, R. (1994) Application of the Time-Varying Transfer Function for Exact Small-Signal Analysis. IEEE Transactions on Power Electronics, 9, 196-205.
https://doi.org/10.1109/63.286812
[3]  Tymerski, R. (1997) Exact Input-to-Output Frequency Response of Time Interval Modulated Switched Networks. Power Electronics Specialists Conference, Vol. 1, 428-434.
https://doi.org/10.1109/PESC.1997.616759
[4]  Mao, Y.-J., Lam, C.-S., Sin, S.-W., Wong, M.-C., Martins, R.P. and Piegari, L. (2018) Review and Selection Strategy for High-Accuracy Modeling of PWM Converters in DCM. Journal of Electrical and Computer Engineering, 2018, Article ID: 3901693.
https://doi.org/10.1155/2018/3901693
[5]  Private Correspondence with Dr. Hua Jin, President and Developer, Powersim Inc., USA on Sept. 14, 2020.
[6]  Wong, R.C. and Groves, J. (1995) An Automated Small-Signal Frequency-Domain Analyzer for General Periodic-Operating Systems as Obtained via Time-Domain Simulation. Power Electronics Specialists Conference, Vol. 2, 801-808.
https://doi.org/10.1109/PESC.1995.474909