全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2018 

Effect of Different Prophylactic Polishing Procedures on the Surface Roughness of Microhybrid and Nanohybrid Resin Composites

Keywords: profilaktik parlatma,mikrohibrit kompozit,nanohibrit kompozit,yüzey pürüzlülü?ü

Full-Text   Cite this paper   Add to My Lib

Abstract:

Objectives: The aim of the present study was to evaluate effects of different professional dental prophylaxis procedures on the surface roughness of a microhybrid (Charisma, Heraeus-Kulzer) and a nanohybrid (Ice, SDI Dental) resin composites. Materials and Methods: 45 disc shaped (2 mm thick /8 mm in diameter) specimens of each restorative materials (totally 90 specimens) were prepared using plexyglass mold. One side of specimens were polished with medium, fine and ultra-fine Sof-Lex (3M-ESPE) discs and 45 specimens of each composite were randomly divided into five groups (n=9). The first group received no prophylaxis treatment and served as control. The other groups received prophlaxis procedures including Detartrine paste (Septodont) with rotating rubber cup, Gelato paste (Keystone Industries) with rotating rubber cup, pumice-water slurry with rotating rubber cup and pumice-water slurry with rotating brush. After prophlaxis procedures surface roughness values of all specimens were measured using an optical prophylometer (Zygo New View 7200, Ametek). Data was statistically analyzed using Mann Whitney U and Kruskal-Wallis Tests. Results: The smoothest surfaces were observed in control groups for both resin composites (p<0.05). Control groups’ surface roughness values of resin composites tested were significantly different (p<0.001). However there were no statistically significant differences between surface roughness values of microhybrid and nanohybrid resin composites that received same prophylaxis treatment. Gelato paste, pumice-water slurry with rotating rubber cup and pumice-water slurry with rotating brush caused significantly greater Ra values than control group but Ra values obtained with Detartrine were not significantly different from the control group in both composite. Conclusions: All prophylaxis procedures tested in the study increased the roughness values of both composites to a level that would be retantive to bacteria. Because of that dental professional must be careful during prophylaxis procedures otherwise repolishing or rarely replacement of the composite restoration would be necessary after prophylaxis

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133