全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

The Application of Current Requirement Test in Large Oil Field Station

Keywords: Large Oil Field Station, Current Requirement Test, Regional Cathodic Protection, Protection Current Density

Full-Text   Cite this paper   Add to My Lib

Abstract:

Up till now, the local cathodic protection renewal of oil & gas field station can be only designed based on previous experience. Therefore, it may lead to some facilities out of protection and inhomogeneous distribution of potential. What is worse is that it can cause mutual interference with surrounding systems, resulting in the malfunction of the cathodic protection system. Through the current requirement test, the current density for the effective protection of storage tanks and pipelines can be obtained. Besides, the type and distribution of the anode ground bed can also be optimized. Thanks to the above calculation and optimization, the protection efficiency of the cathodic protection system can be significantly improved. In this paper, on-site current requirement test was conducted in a large oil field station. The simulation of the cathodic protection system was conducted in certain area separately so as to confirm the minimum current density value required for the effective cathodic protection and the potential distribution in certain area, all of which would benefit the redesign and renewal of the local cathodic protection system in the reservoir area.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133