全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2017 

Energy Saving Assessment for Building Envelope of Supermarket Based on EnergyPlus and Openstudio

Keywords: Building Envelope, Heat Balance Equation, EnergyPlus, Openstudio, Energy Saving, Simulation, Model Calibration

Full-Text   Cite this paper   Add to My Lib

Abstract:

In this paper, a supermarket model located in Kathmandu is established by simulation software EnergyPlus. As one possible approach to improving the energy performance of the commercial building, this study develops an whole building energy simulation model to investigate the influence of two types of alternative walls – a insulated wall, a brick wall with 50 mm air gap and 4 inch additional brick wall on the energy performance of Bhatbhateni department store building at Krishna Galli, Lalitpur, Nepal. Single and double glazed glasses with varies thermal properties has been analyzed. This study finds that the 1 inch insulated external walls significantly improve the performance compared to the non-insulated wall. It is also found that the double glazed glass window models Envision and Reflectasol reduces the largest amount of energy. The results of this study can be used as basis data for estimating the potential energy saving with the replacement of alternative envelope (wall and window) under similar climate and orientation of the buildings.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133