Ischaemic Heart Disease (IHD) or Coronary heart disease means that the heart is not getting enough blood and oxygen supply through the coronary arteries. The most common cause of this disease is the process of atherosclerosis in the coronary arteries. Although significant progress has been made in the management of ischaemic heart disease (IHD) The number of severe IHD patients is increasing. The treatment options for IHD have not changed much over the last three decades,which is divided between medications, coronary Angioplasty and Coronary artery bypass surgery. Thus it was crucial to develop new, non-invasive therapeutic strategies in case of Failure of medical or interventional therapy or in case patient is not fit for surgery or angioplasty. In this study, we are pleased to reveal a novel technique that was carried out on a human model. We aimed to develop low-intensity pulsed ultrasound (LIPUS) therapy for the treatment of patients with Ischaemic Heart Disease. We have set up the inclusion and exclusion criteria, the treatment protocol of LIPUS on IHD patients. In this limited group of IHD patients, We found promising clinical results and improvement on myocardial functions.
References
[1]
Okrainec, K., Banerjee, D.K. and Eisenberg, M.J. (2004) Coronary Artery Disease in the Developing World. American Heart Journal, 148, 7-15. https://doi.org/10.1016/j.ahj.2003.11.027
[2]
Hata, J. and Kiyohara, Y. (2013) Epidemiology of Stroke and Coronary Artery Disease in Asia. Circulation Journal, 77, 1923-1932.
Kenichiro, H., Kenta, I., Kentaro, A., et al. (2014) Low-Intensity Pulsed Ultrasound Induces Angiogenesis and Ameliorates Left Ventricular Dysfunction in a Porcine Model of Chronic Myocardial Ischemia. PLoS ONE, 9, e104863. https://doi.org/10.1371/journal.pone.0104863
[5]
Bernal, A., Pérez, M.L, De Lucas, B., et al. (2015) Low-Intensity Pulsed Ultrasound Improves the Functional Properties of Cardiac Mesoangioblasts. Stem Cell Reviews and Reports, 11, 852-865. https://doi.org/10.1007/s12015-015-9608-6
[6]
Siegel, R.J., Atar, S., Fishbein, M.C., et al. (2000) Noninvasive, Transthoracic, Low-Frequency Ultrasound Augments Thrombolysis in a Canine Model of Acute Myocardial Infarction. Circulation, 101, 2026-2029. https://doi.org/10.1161/01.CIR.101.17.2026
[7]
Toyama, Y., Sasaki, K.I., Tachibana, K., et al. (2012) Ultrasound Stimulation Restores Impaired Neovascularization-Related Capacities of Human Circulating Angiogenic Cells. Cardiovascular Research, 95, 448-459. https://doi.org/10.1093/cvr/cvs173
[8]
Higashi, Y., Azuma, N., Takeishi, Y., et al. (2015) Effect of a Low-Intensity Pulsed Ultrasound Device, SX-1001, on Clinical Symptoms in Buerger Disease with Limb Ischemia. International Heart Journal, 56, 632-638. https://doi.org/10.1536/ihj.15-191