POCT技术研究现状及临床应用
Technologies Research Status and Clinical Applications of Point of Care Testing

DOI: 10.12677/HJBM.2021.111004, PP. 23-30

Keywords: POCT,便携式检测技术,临床应用
POCT
, Portable Detection Technology, Clinical Application

Full-Text   Cite this paper   Add to My Lib

Abstract:

POCT (Point of Care Testing)是一种在采样现场进行的、利用便携式分析仪器及配套试剂快速得到结果的检测方式,本文主要阐述了POCT (Point of Care Testing)的微流控芯片技术、传感器技术、干化学技术、免疫层析技术、生物芯片技术等主要检测技术,并介绍了其在临床上的广泛应用。
POCT (Point of Care Testing) is defined as medical diagnostic testing that can be performed at the patient’s bedside. This paper mainly discussed various POCT (Point of Care Testing) devices devel-oped by different technologies including microfluidics, sensor technology, dry reagent technology, immunochromatography, biochip technology. As healthcare becomes more consumer-focused, POCT (Point of Care Testing) is rapidly expanding worldwide and has been widely used in clinical.

References

[1]  李琦. POCT的应用现状与不足[J]. 临床检验杂志, 2013(3): 22-24.
[2]  张玲. 即时检验(POCT)的应用[J]. 医疗装备, 2015, 28(1): 49-50.
[3]  赵卫国. 即时检验[M]. 上海: 上海科学技术出版社, 2007: 38.
[4]  贺志安. 检验仪器分析[M]. 北京: 人民卫生出版社, 2010: 202-205.
[5]  辛晓敏, 关秀茹. 现代临床检验技术与应用[M]. 北京: 科学出版, 2005: 232-234.
[6]  丛辉, 王惠民, 王跃国. 微流控芯片技术及应用展望[J]. 现代检验医学杂志, 2005(1): 88-89.
[7]  李阳, 王云龙. 免疫层析技术的研究进展[J]. 中国卫生检验杂志, 2015, 25(22): 3978-3980.
[8]  于新芬, 潘劲草, 孟冬梅. 生物传感器在医学检测中的应用[J]. 检验医学与临床, 2004, 1(3): 120-122.
[9]  马新秀, 胡文忠, 冯可, 等. 生物芯片在微生物检测中的应用[J]. 商品与发酵工业, 2018(2): 273-277.
[10]  Oblath, E.A., et al. (2013) A Microfluidic Chip Integrating DNA Extraction and Real-Time PCR for the Detection of Bacteria in Saliva. Lab on a Chip, 7, 1325-1332.
https://doi.org/10.1039/c3lc40961a
[11]  Liu, P., et al. (2011) Integrated DNA Purification, PCR, Sample Cleanup, and Capillary Electrophoresis Microchip for Forensic Human Identification. Lab on a Chip, 11, 1041-1048.
https://doi.org/10.1039/c0lc00533a
[12]  Beyor, N., Yi, L., Seo, T.S., et al. (2009) Integrated Capture, Concentration, Polymerase Chain Reaction, and Capillary Electrophoretic Analysis of Pathogens on a Chip. Analytical Chemistry (Washington), 81, 3523-3528.
https://doi.org/10.1021/ac900060r
[13]  Toriello, N.M., et al. (2008) Integrated Microfluidic Bioprocessor for Single-Cell Gene Expression Analysis. Proceedings of the National Academy of Sciences of the United States of America, 105, 20173-20178.
https://doi.org/10.1073/pnas.0806355106
[14]  Easley, C.J., et al. (2006) A Fully Integrated Microfluidic Genetic Analysis System with Sample-in-Answer-Out Capability. Proceedings of the National Academy of Sciences of the United States of America, 103, 19272-19277.
https://doi.org/10.1073/pnas.0604663103
[15]  Chang, C.M. (2013) Integrated Three-Dimensional System-on-Chip for Direct Quantitative Detection of Mitochondrial DNA Mutation in Affected Cells. Biosensors & Bioelectronics, 48, 6-11.
https://doi.org/10.1016/j.bios.2013.02.015
[16]  Wang, J.H., et al. (2013) An Integrated Chip Capable of Performing Sample Pretreatment and Nucleic Acid Amplification for HIV-1 Detection. Biosensors & Bioelectronics, 41, 484-491.
https://doi.org/10.1016/j.bios.2012.09.011
[17]  Chen, D., et al. (2010) An Integrated, Self-Contained Microfluidic Cassette for Isolation, Amplification, and Detection of Nucleic Acids. Biomedical Microdevices, 12, 705-719.
https://doi.org/10.1007/s10544-010-9423-4
[18]  单万水. 从层析荧光到微流控生物芯片——现场快速检验(POCT)技术基础概述[J]. 中国医疗器械信息, 2017, 23(7): 45-52.
[19]  Apple, F.S. (1999) Simultaneous Rapid Measurement of Whole Blood Myoglobin, Creatine Kinase MB, and Cardiac Troponin I by the Triage Cardiac Panel for Detection of Myocardial Infarction. Clinical Chemistry, 45, 199-205.
https://doi.org/10.1093/clinchem/45.2.199
[20]  谢华斌, 张忠英. POCT血糖仪的质量管理[J]. 实验与检验医学, 2008, 26(2): 173-174.
[21]  樊绮诗, 钱士匀, 等. 临床检验仪器与技术[M]. 北京: 人民卫生出版社, 2015.
[22]  陈宇琼, 朱清峰, 李国祥, 等. 放射免疫分析与化学发光免疫检测应用对比及发展趋势[J]. 同位素, 2014, 27(3): 188-192.
[23]  董家书, 蒋丽君. POCT的发展及应用现状[J]. 医学研究杂志, 2009, 38(10): 122-123.
[24]  Shi, W.D., et al. (2013) Four-Part Leukocyte Differential Count Based on Sheathless Microflow Cytometer and Fluorescent Dye Assay. Lab on a Chip, 7, 1257-1265.
https://doi.org/10.1039/c3lc41059e
[25]  Montagnana, M., Caputo, M., Giavarina, D., et al. (2009) Overview on Self-Monitoring of Blood Glucose. Clinica Chimica Acta, 402, 7-13.
https://doi.org/10.1016/j.cca.2009.01.002
[26]  张坚. 医院急救医学装备配置中POCT的应用与管理[J]. 生物医学工程学进展, 2013, 34(3): 191-193.
[27]  Aguilera-Herrador, E. (2010) Analytical Connotations of Point-of-Care Testing. The Analyst, 9, 2220-2232.
https://doi.org/10.1039/c0an00307g

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133