全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Fast four

DOI: 10.1177/0309324718810593

Keywords: Tomography,in situ tests,four-dimensional measurement,inverse methods,integrated digital volume correlation,projection-based digital volume correlation

Full-Text   Cite this paper   Add to My Lib

Abstract:

A projection-based digital volume correlation method (presented in a companion paper) is extended to an integrated approach for the calibration of an elastoplastic law based on a single radiograph per loading step. Instead of following a two-step sequential procedure (i.e. first, measurement of the displacement field; second, identification), the integrated method aims at identifying few model parameters directly from the gray-level projections. The analysis of an in situ tensile test composed of 127 loading steps performed in 6 min is presented. An isotropic elastoplastic constitutive law with free-form hardening behavior (i.e. controlled by only eight parameters) is identified and shows a ductile behavior (up to 6.3% strain before failure). A large improvement on the residual quality is shown and validates the proposed model and procedure. The obtained displacement fields are similar to those measured with no mechanical integration. A different parameterization of the constitutive law provides a very close result, thereby assessing the robustness of the procedure

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133