全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2018 

Step

DOI: 10.1177/1744259118764823

Keywords: Sol-air temperature,sol-air thermometer,thermal network model,heat transfer coefficient,thermal transmittance,Thevenin’s theorem

Full-Text   Cite this paper   Add to My Lib

Abstract:

The environmental boundary conditions of the building exterior surface could be expressed in terms of the sol-air temperature To and the heat transfer coefficient ho. This has previously been derived by applying Thevenin’s theorem to the linear thermal network model of the convective and radiative environment. Here, the sol-air thermometer, previously used only for measurement of To, was applied for accurate measurement of ho. The step-transient method was used, where the temperature of the sol-air thermometer was initially raised to above To and then monitored during its transient return to thermal equilibrium. This method was validated by (1) comparison of ho results against values obtained with a steady-state method and (2) comparison of predicted heat flux against the electrical heater power, supplied for validation purpose. Accurate results were obtained, with 7.3% measurement uncertainty. The present sol-air thermometer time constant τ was around 1 h. Based on predictions from dynamic modelling, the τ could be reduced 10-fold, with only small effects on the accuracy from heat loss through the insulation layer

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133