-  2018 

Rain resistance of fa?ades with fa?ade details: A summary of three field and laboratory studies

DOI: 10.1177/1744259117713265

Keywords: Driving rain,rain intrusion,water leakage,moisture,wall,window,risk assessment,measurements,EN 12865

Full-Text   Cite this paper   Add to My Lib

Abstract:

One of the main functions of the exterior walls and fa?ades is to protect the indoor and the sensitive parts of construction from the outdoor climate. Exposure of driving rain is the most prominent moisture source a wall has to resist. Despite this, there is a lack of information on rain resistance. Field measurements on real-life external walls show that recurrent water leakage under driving rain conditions is observed in five out of seven new-built houses in Sweden, including those with ventilated fa?ades. About a 100 commercial laboratory fa?ade tests, mounted by fa?ade suppliers, and targeted laboratory experiments showed that it is almost impossible to achieve fully tight fa?ade solutions, and keep them sealed. Nearly, all test walls with fa?ade details leaked, almost regardless of fa?ade type and sealing efforts. The results from field and laboratory measurements of rain resistance in new buildings in Sweden show that fa?ades are usually not water-tight and also that very small deficiencies can cause substantial amount of water leakage