全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

Treatment of juxta

DOI: 10.1177/1129729818793102

Keywords: Paclitaxel eluting ballons,standard angioplasty,stenosis,juxta-anastomotic region,distal radiocephalic fistulas

Full-Text   Cite this paper   Add to My Lib

Abstract:

The aim of our study is to report the results of two types (type A, type B) paclitaxel drug-coated balloon compared with standard percutaneous transluminal angioplasty in the treatment of juxta-anastomotic stenoses of mature but failing distal radiocephalic hemodialysis arteriovenous fistulas. Two groups of 26 and 44 patients treated with two different drug-coated balloon are compared with a control group of 86 treated with standard percutaneous transluminal angioplasty. A color Doppler ultrasound was performed to evaluate stenosis and for treatment planning. We assess primary patency, defined as the absence of dysfunction of the arteriovenous fistulas, patent lesion or residual stenosis < 30% and no need for further reintervention of target lesion. Primary patency and secondary patency are evaluated after 12?months with color Doppler ultrasound for the whole arteriovenous fistulas, defined as absolute (absolute primary patency, absolute secondary patency) and target lesion. Postprocedural technical and clinical success was 100%. After 12?months, absolute primary patency is 81.8% for type A, 84.1% type B, and 54.7% for standard percutaneous transluminal angioplasty; target lesion primary patency is 92% type A, 86.4% type B, and 62.8% standard percutaneous transluminal angioplasty; absolute secondary patency is 95.4% type A, 95.5% type B, and 80.7% standard percutaneous transluminal angioplasty; target lesion secondary patency is 100% type A, 97.7% type B, and 80.7% standard percutaneous transluminal angioplasty. All the patients treated with drug-coated balloon (type A?+?type B) have an absolute primary patency of 83.3%, a target lesion primary patency of 87.9%, an absolute secondary patency of 95.5%, and a target lesion secondary patency of 98.4%. Our study confirms that the use of drug-coated balloon, indiscriminately among different brands, improves primary patency with statistically significant difference in comparison with standard percutaneous transluminal angioplasty and decreases reintervention of target lesion in juxta-anastomotic stenoses of failing distal arteriovenous fistulas maintaining the radiocephalic fistula as long as possible

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133