- 1999
氧弹分解—冷原子吸收法测定煤中汞Keywords: 冷原子吸收,氧弹,煤,汞 cold atomic absorption, oxygen bomb, coal, mercury Abstract: 利用氧弹燃烧分解煤样, 采用JDS200 型微分测汞仪测定煤中汞的含量。方法检出限为0.13 ng/m L, 相对标准偏差4.8 % , 回收率86 % ~115 % , 校准曲线相关系数0.9996 。试验结果表明, 该方法简便、快速、准确, 能够有效地测定煤中痕量汞。 This article introduces the method of oxygen bomb combustion cold atomic absorption for determination of the mercury in coal. The determination limit is below 0 13 ng/ml and recovery is 86%~115%. RSD is less than 3 0% and the correlation coefficient is 0 9996. The experimental result is show that the method is simple, convenient and accurate. It is a very practical method for analysis of the trace mercury in coal
|