- 2019
Model Validation and Process Design of Continuous Single Pass Tangential Flow Filtration Focusing on Continuous Bioprocessing for High Protein ConcentrationsDOI: https://doi.org/10.3390/pr7110781 Abstract: In this study, the continuous Single-Pass Tangential Flow Filtration (SPTFF) concept is adapted for high protein concentrations. The work is based on the previously validated physico-chemical model for low concentrations and high viscosities. The model contains the Stagnant Film Model for concentration polarization, as well as the Boundary Layer Model for the mass transfer through the membrane. The pressure drop is calculated as a function of the Reynolds number. By performing preliminary experiments with a single ultrafiltration (UF) cassette, the model parameter are determined. The presented model is validated for a multi-step Single-Pass Tangential Flow Filtration. With subsequent simulation studies, an optimized process is found and confirmed by experiments. The outcome of this work shows the potential to optimize this multi-parameter dependent unit operation. This is reached by a model-based optimization allowing significant reduction of experimental efforts and applying the Quality by Design approach consistently. Furthermore, a comparison between the experimental setup and a commercial module is examined. View Full-Tex
|