Ventilation of an Isolated Subsurface Structure Induced by Natural Forces

DOI: https://doi.org/10.3390/infrastructures4020033

Full-Text   Cite this paper   Add to My Lib

Abstract:

The subsurface infrastructure comprises many types of isolated structures, a type of confined space. This study reports on the effect of engine operating time, number/area and spacing of openings in the manhole cover, and operation during different seasons on ventilation of a subsurface, isolated, pre-cast concrete chamber through opening(s) in the manhole cover. Carbon monoxide (CO) emitted by a small gasoline engine reached 800 ppm in 30 s at the start of testing. Ventilation occurred continuously. Generally, the concentration of CO reported by instruments located at different heights was the same for the same moment in time, suggestive of a rapidly well-mixed atmosphere. Mathematical modelling suggested that ventilation occurred through a zero-order kinetic process. Statistical testing suggested that optimization of ventilation is possible through design modifications such as change in the number/area/shape/spacing/geometric arrangement of openings in the manhole cover. Optimizing the rate of ventilation induced by natural forces during the interval between entries will reduce the risk of explosion of the confined atmosphere and overexposure of workers when opening the manhole cover to prepare for entry. This improvement will have immense implications to safety worldwide. View Full-Tex