全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2019 

An Amplifier-Less Acquisition Chain for Power Measurements in Series Resonant Inverters

DOI: https://doi.org/10.3390/s19194343

Full-Text   Cite this paper   Add to My Lib

Abstract:

Successive approximation register (SAR) analog-to-digital converter (ADC) manufacturers recommend the use of a driver amplifier to achieve the best performance. When a driver amplifier is not used, the conversion speed is severely penalized because of the need to meet the settling time constraint. This paper proposes a simple digital correction method to raise the performance (conversion speed and/or accuracy) when the acquisition chain lacks a driver amplifier. It is intended to reduce the cost, size and power consumption of the conditioning circuit while maintaining acceptable performance. The method is applied to the measurement of the output power delivered by a series resonant inverter for domestic induction heating. View Full-Tex

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133