- 2017
Using Auditory Steady-State Responses for Measuring Hearing Protector Occlusion EffectKeywords: Auditory steady-state responses, hearing protection devices, occlusion effect Abstract: The currently available methods for measuring the occlusion effect (OE) of hearing protection devices (HPDs) have limitations. Objective microphonic measurements do not assess bone-conducted sounds directly transmitted to the cochlea. Psychophysical measurements at threshold are biased due to the low-frequency masking effects from test participants’ physiological noise and the variability of measurements based on subjective responses. An auditory steady-state responses (ASSRs) procedure is used as a technique that might overcome these limitations
|