- 2018
Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealantDOI: 10.1016/j.adro.2017.12.005 Abstract: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed tomography (CT) scans after the use of tract sealants can mimic malignant tract seeding (MTS) and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs
|