Preparation of New Uric Acid Sensors Based on Iodide Selective Electrode

DOI: 10.4236/ajac.2020.115016, PP. 205-212

Keywords: Uric Acid Electrode, Uricase, Enzyme, Iodide Selective Electrode, Uric Acid in Blood

Full-Text   Cite this paper   Add to My Lib

Abstract:

An electrode for uric acid has been prepared by using an iodide selective electrode with the uricase enzyme. The iodide selective electrode used was prepared from 10% TDMAI and PVC according to our previous study. The enzyme was immobilized on the iodide electrode by holding it at pH 7 phosphate buffer for 20 min at room temperature. The H2O2 formed from the reaction of uric acid was determined from the decrease of iodide concentration that was present in the reaction cell. The potential change was linear in the 2 × 10-5 to 2 × 10-4 M uric acid concentration (3 - 34 mg uric acid/100ml blood) range. Uric acid contents of some blood samples were determined with the new electrode and consistency was obtained with a colorimetric method. The effects of pH, iodide concentration, the amount of enzyme immobilized and the operating temperature were studied. No interference of ascorbic acid, glucose and urea was observed.

References

[1]  Updike, S. and Hicks, G.P. (1967) Reagentless Substrate Analysis with Immobilized Enzymes. Science, 158, 270-272.
https://doi.org/10.1126/science.158.3798.270
[2]  Kalcher, K., Svancara, I., Buzuk, M., Vytras, K. and Walcarius, A. (2009) Electrochemical Sensors and Biosensors Based on Heterogeneous Carbon Materials. Monatshefte für Chemie—Chemical Monthly, 140, 861-889.
https://doi.org/10.1007/s00706-009-0131-9
[3]  Raab, L.S., Decker, G.L., Jonas, A.J., Kaetzel, M.A. and Dedman, J.R. (1991) Glucocoticoid Regulation of Rat Liver Urate Oxidase. Journal of Cellular Biochemistry, 47, 18-30.
https://doi.org/10.1002/jcb.240470104
[4]  Martinez-Pérez, D., Ferrer, M.L. and Mateo, C.R. (2003) A Reagent Less Fluorescent Sol-Gel Biosensor for Uric Acid Detection in Biological Fluids. Analytical Biochemistry, 322, 238-242.
https://doi.org/10.1016/j.ab.2003.08.018
[5]  Gülce, H., Özyörük, H., Çelebi, S.S. and Yÿldÿz, A. (1995) Amperometric Enzyme Electrode for Aerobic Glucose Monitoring Prepared by Glucose Oxidase Immobilized in Poly(vinylferrocenium). Journal of Electroanalytical Chemistry, 394, 63-70.
https://doi.org/10.1016/0022-0728(95)04013-E
[6]  Sun, L.-X., Xu, F. and Okada, T. (1998) Studies on Optimization of a Platinum Catalyst and Porphine Modified, Pyrolytic Graphite, Amperometric, Glucose Sensor by Sequential Level Elimination Experimental Design. Talanta, 47, 1165-1174.
https://doi.org/10.1016/S0039-9140(98)00195-7
[7]  Campanella, L. and Tomassetti, M. (1989) Sensors in Pharmaceutical Analysis. Selective Electrode Rev., 11, 69-73.
[8]  Losada, J. and Pilar, M. (1997) A Glucose Amperometric Sensor Based on Covalent Immobilization of Glucose Oxidase in Poly-2-Aminoaniline Film via Chloranil on Platinized Platinum Electrode. Electroanalysis, 9, 1416-1421.
https://doi.org/10.1002/elan.1140091808
[9]  Nagy, G., Von Storp, L.H. and Guilbault, G.G. (1973) Enzyme Electrode for Glucose Based on an Iodide Membrane Sensor. Analytica Chimica Acta, 66, 443-445.
https://doi.org/10.1016/S0003-2670(01)82564-2
[10]  Hitti, I.K.A., Moody, G.J. and Thomas, J.D.R. (1984) Glucose Oxidase Membrane Systems Based on Poly(vinyl chloride) Matrices for Glucose Determination with an Iodide Ion-Selective Electrode. Analyst, 109, 1205-1208.
https://doi.org/10.1039/an9840901205
[11]  Merkoçi, A., Fabregas, E. and Alegret, S. (1999) Consolidated Biocomposite Membrane Technology for Production of Potentiometric Biosensors. Sensors & Actuators, B, 60, 97-105.
https://doi.org/10.1016/S0925-4005(99)00262-2
[12]  Ali, U., Alvi, N.H., Ibupoto, Z., Nur, O., Willander, M. and Danielsson, B. (2011) Selective Potentiometric Determination of Uric Acid with Uricase Immobilized on ZnO Nanowires. Sensors and Actuator B, 152, 241-247.
https://doi.org/10.1016/j.snb.2010.12.015
[13]  Azmi, N.E., Ramli, N.I., Abdullah, J., Hamid, M.A.A., Sidek, H., Rahman, S.A., Ariffin, N. and Yusof, N.A. (2015) A Simple and Sensitive Fluorescence Based Biosensor for the Determination of Uric Acid Using H2O2-Sensitive Quantum Dots/Dual Enzymes. Biosensors and Bioelectronics, 67, 129-133.
https://doi.org/10.1016/j.bios.2014.07.056
[14]  Rezaei, B., Shams-Ghahfarokhi, L., Havakeshian, E. and Ensafi, A.A. (2016) An Electrochemical Biosensor Based on Nanoporous Stainless Steel Modified by Gold and Palladium Nanoparticles for Simultaneous Determination of Levodopa and Uric Acid. Talanta, 158, 42-50.
https://doi.org/10.1016/j.talanta.2016.04.061
[15]  Somer, G., Kalayci, S. and Ekmekçi, G. (2001) Preparation and Application of Iodide-Mercury Selective Membrane Electrode Based on Ion Exchangers. Sensors & Actuators B, 81, 122-127.
https://doi.org/10.1016/S0925-4005(01)00942-X
[16]  Srinivasan, K. and Rechnitz, G.A. (1969) Selectivity Studies on Liquid Membrane, Ion Selective Electrodes. Analytical Chemistry, 41, 1203-1208.
https://doi.org/10.1021/ac60279a014

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133