Transient Stability Analysis of 33 KV Transmission Network of Egi Community, Nigeria

DOI: 10.4236/jpee.2020.83002, PP. 18-35

Keywords: Rotor Angle, Transient Stability, Swing Equation, Angular Speed, Differential Changes, Trapezoidal Rule, Fault Clearing Time, Critical Clearing Time

Full-Text   Cite this paper   Add to My Lib

Abstract:

Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The supply is taken from Egi generating station located at Total Nigeria Limited Gas Plant Obite at voltage level of 33 KV to Egi communities. This work focuses on the transient nature of network stability since transient fault is the most dangerous in elec-trical systems. The swinging of the generator rotor in the event of transient three-phase short circuit fault can be monitored by the circuit breakers and the protective relays which causes mal-functioning of the circuit breakers and pro-tective relays leading to abnormal behavior of the network. Therefore, data obtained from the power station were used as a case study of Independent Power Producer (IPP) in Nigeria. For investigation of the power angle, angular velocity, rotor angle differential changes, and angular velocity differential changes, an electrical transient analyzer tool was employed (ETap version 16.00) for circuit breaker and protective relay time setting of (0.00, 0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60). The work used the Trapezoidal numerical technique for data analysis. The graphs were plotted using Matlab R2015a and the results obtained showed that when a symmetrical three-phase short circuit fault occur at one or any of the feeders, the fault must be cleared as quick as possible through the coordination of the circuit breakers and protective relays. For this research work, 17 cycles corresponding to relay time setting of t = 0.34 s were recommended and at each cycle, changes in time with respect to changes in rotor angle, angular velocity, rotor differential and angular velocity differential were calculated on the power network simultaneously. The results demonstrated that the Trapezoidal method is numerically stable, accurate and has faster respond time when compared to Modified Euler and swing equation techniques in event of fault occurrence in network.

References

[1]  Rapu, I. and Okeke, C. (2018) Presentation on Egi/Rivers State Ministry of Power Interface.
[2]  Total Nigeria Maintenance Report (2019) JV-Field Operations-OML 58 Maintenance Report. Total Nigeria, Electrical Methods, JV Operation.
[3]  Ahiakwo, C.O., Braide, S.L. and Aghaukwu, N.C. (2019) Analysis of 232 KV Power Transmission Stability in a Developing Nation. American Journal of Engineering Research, 8, 124-132.
[4]  Obe, E.S. (2009) Lecture Note on Synchronous Machines.
[5]  Duncan, G. (2008) Power System Analysis and Design. 2nd Edition, Wiley Publishers, New York.
[6]  Gupta (2005) Power System Engineering. 2nd Edition, S. Chand Publishers, India.
[7]  Omorogiuwa, E. and Elechi, P. (2015) Impact of Distributed Generation Placement on Stability of Power Network in Nigeria. IOSR Journal of Electrical and Electronics Engineering, 10, 61-69.
[8]  Omorogiuwa, E. and Elechi, P. (2015) Economic Effects of Technical and Non- Technical Losses in Nigeria Power Transmission System. IOSR Journal of Electrical and Electronics Engineering, 10, 61-69.
[9]  Kai, S. (2018) Lecture Notes on Power System Analysis II and 3-Power System Stability.
[10]  Enemuoh, F.O. (2012) Simulation Modelling of Voltage Stability of an Interconnected Electric Power System Network.
[11]  Ghorban, A.K.M. and Mozafari, B. (2012) Impact of SVC on Transmission Lines. Electric Power and Energy System, 4, 702-709.
https://doi.org/10.1016/j.ijepes.2012.04.029
[12]  Kumur, A. and Dubey, S.B. (2013) Enhancement of Transient Stability in Transmission Line Using SVC Fast Controller. International Journal of Recent Technology and Engineering, 2, 7-13.