Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal

DOI: 10.4236/ijcce.2020.91001, PP. 1-14

Keywords: Analysis of the Performances, The Photovoltaic Solar Energy, Grid-Connected PV System, Senegal

Full-Text   Cite this paper   Add to My Lib

Abstract:

This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection.

References

[1]  Lam, K.H., Lai, T.M., Lo, W.C. and To, W.M. (2012) The Application of Dynamic Modelling to the Grid-Connected PV (Photovoltaic) Systems. Energy, 46, 264-274.
https://doi.org/10.1016/j.energy.2012.08.023
[2]  Santiago, S., Aissa, C. and Engin, K. (2013) Automatic Fault Detection in Grid Connected PV Systems. Solar Energy, 94, 119-127.
https://doi.org/10.1016/j.solener.2013.05.001
[3]  Aristobal, A.J. and Gordillo, G. (2008) Performance Monitoring Results of the First Grid-Connected BIPV System in Colombia. Renewable Energy, 33, 2475-2484.
https://doi.org/10.1016/j.renene.2008.01.018
[4]  Hoz, J.D.L., Boix, O., Martin, H., Martin, B. and Graells, M. (2010) Promotion of Grid-Connected Photovoltaic System in Spain: Performance Analysis of the Period 1998-2008. Renewable and Sustainable Energy Reviews, 14, 2547-2563.
https://doi.org/10.1016/j.rser.2010.07.059
[5]  Jannuzzi, G.D.M. and Melo, C.A.D. (2013) Grid-Connected Photovoltaic in Brasil: Policies and Potential Impacts for 2030. Energy for Sustainable Development, 17, 40-45.
https://doi.org/10.1016/j.esd.2012.10.010
[6]  Sidi, C.E.B.E., Ndiaye, M.L., Bah, M.E., Mbodj, A., Ndiaye, A. and Ndiaye, P.A. (2016) Performance Analysis of the First Large-Scale (15 MWp) Grid-Connected Photovoltaic Plant in Mauritania. Energy Conversion and Management, 119, 411-421.
https://doi.org/10.1016/j.enconman.2016.04.070
[7]  Loi n°98-29 du 14 avril 1998 relative au secteur de l’électricité.
[8]  Loi n°2010-21 portant loi d’orientation sur les énergies renouvelables.
[9]  https://www.sma.de/fr/produits/onduleurs-a-batterie
[10]  http://www.sma.de/fr/produits/surveillance-controle/sunny-explorer.html
[11]  System of grid-L’expertise des solutions Energetiques Durable-Photovoltaique: Les indicateurs de rendement et de performance-Décembre 2012.
[12]  De Condona, S. and Lopez, L. (1999) A General Multivariate Qualitative Model for Sizin Stand alone Photovoltaic Systems. Solar Energy Materials & Solar Cells, 59, 185-197.
https://doi.org/10.1016/S0927-0248(99)00020-3
[13]  Solutions photovoltaiques autonomes-Anne Labouret-25 novembre 2010.
[14]  Labouret, A. and Villoz, M. (2006) Energie Solaire Photovoltaique. 3ème Edition, Dunod, Paris.
[15]  Systèmes photovoltaique raccordés au réseau. Guide de rédaction de cahier de charges. Techniques de consultation à destination des maitres d’ouvrages. ADEME Version 2007.