Background: Narrow-diameter implants (3.0 - 3.5 mm range) have been introduced for the replacement of teeth with insufficient bone structure and/or limited mesiodistal or interimplant spaces, and appear to offer clinical results similar to those obtained with implants of greater diameter. Studies using extra-narrow-diameter implants (2.8 mm) are scarce. Case Presentation: A 59-year-old male patient received two extra-narrow-diameter implants, 2.8 × 11 mm in the region between elements 11 and 14. Together, two 3.5 × 8.5 mm SYSTHEX® platform 4.1 implants were installed in the region of elements 15 and 16 to provide greater stability in the occlusion. Of four previous implants on the maxillary left side, one in the region between the elements 23 and 24 that was located in a very apical position and vestibularized was removed. The provisional was already installed on the elements 11, 21, and 22 with the metal cores already prepared and with the Globteck®implants in the region of the elements 23, 24, and 27. The functional and esthetic results were satisfactory. Conclusions: Insertion of extra-narrow-diameter implants of 2.8 mm in the maxillary anterior region is a reliable option in a patient with absence of elements 12 and 13, restoring masticatory function and aesthetics in the upper arch.
References
[1]
Schiegnitz, E. and Al-Nawas, B. (2018) Narrow-Diameter Implants: A Systematic Review and Meta-Analysis. Clinical Oral Implants Research, 29, 21-40. https://doi.org/10.1111/clr.13272
[2]
Marcello-Machado, R.M., Faot, F., Schuster, A.J., Nascimento, G.G. and Del Bel Cury, A.A. (2018) Mini-Implants and Narrow-Diameter Implants as Mandibular Overdenture Retainers: A Systematic Review and Meta-Analysis of Clinical and Radiographic Outcomes. Journal of Oral Rehabilitation, 45, 161-183. https://doi.org/10.1111/joor.12585
[3]
Lemos, C.A., Verri, F.R., Batista, V.E., Júnior, J.F., Mello, C.C. and Pellizzer, E.P. (2017) Complete Overdentures Retained by Mini Implants: A Systematic Review. Journal of Dentistry, 57, 4-13. https://doi.org/10.1016/j.jdent.2016.11.009
[4]
Aunmeungtong, W., Kumchai, T., Strietzel, F.P., Reichart, P.A. and Khongkhunthian, P. (2017) Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial. Clinical Implant Dentistry and Related Research, 19, 328-340. https://doi.org/10.1111/cid.12461
[5]
Andersen, E., Saxegaard, E., Knutsen, B.M. and Haanaes, H.R. (2001) A Prospective Clinical Study Evaluating the Safety and Effectiveness of Narrow-Diameter Threaded Implants in the Anterior Region of the Maxilla. The International Journal of Oral & Maxillofacial Implants, 16, 217-224.
[6]
Davarpanah, M., Martinez, H., Tecucianu, J.F., Celletti, R. and Lazzara, R. (2000) Small-Diameter Implants: Indications and Contraindications. Journal of Esthetic Dentistry, 12, 186-194. https://doi.org/10.1111/j.1708-8240.2000.tb00221.x
[7]
Carlsson, G.E. and Omar, R. (2010) The Future of Complete Dentures in Oral Rehabilitation. A Critical Review. Journal of Oral Rehabilitation, 37, 143-156. https://doi.org/10.1111/j.1365-2842.2009.02039.x
[8]
Tarnow, D.P., Cho, S.C. and Wallace, S.S. (2000) The Effect of Inter-Implant Distance on the Height of Inter-Implant Bone Crest. Journal of Periodontology, 71, 546-549. https://doi.org/10.1902/jop.2000.71.4.546
[9]
Corcuera-Flores, J.R., Pérez-Fierro, M., Blanco-Carrión, A., Torres-Lagares, D., Castellanos-Cosano, L. and Machuca-Portillo, G. (2020) Bone Loss around Narrow Implants versus Standard Diameter Implants: Retrospective 2-Years Case-Control Study. Journal of Clinical and Experimental Dentistry, 12, e79-e84. https://doi.org/10.4317/jced.56422
[10]
Brånemark, P.I., Adell, R., Breine, U., Hansson, B.O., Lindström, J. and Ohlsson, A. (1969) Intra-Osseous Anchorage of Dental Prostheses. I. Experimental Studies. Scandinavian Journal of Plastic and Reconstructive Surgery, 3, 81-100. https://doi.org/10.3109/02844316909036699
[11]
Jayesh, R.S. and Dhinakarsamy, V. (2015) Osseointegration. Journal of Pharmacy and Bioallied Sciences, 7, S226-S229. https://doi.org/10.4103/0975-7406.155917
[12]
Delgado-Ruiz, R., Silvente, A.N. and Romanos, G. (2019) Deformation of the Internal Connection of Narrow Implants after Insertion in Dense Bone: An in Vitro Study. Materials, 12, 1833. https://doi.org/10.3390/ma12111833
[13]
Salvi, G.E. and Lang, N.P. (2001) Changing Paradigms in Implant Dentistry. Critical Reviews in Oral Biology & Medicine, 12, 262-272. https://doi.org/10.1177/10454411010120030501
[14]
Ioannidis, A., Gallucci, G.O., Jung, R.E., Borzangy, S., Hämmerle, C.H. and Benic, G.I. (2015) Titanium-Zirconium Narrow-Diameter versus Titanium Regular-Diameter Implants for Anterior and Premolar Single Crowns: 3-Year Results of a Randomized Controlled Clinical Study. Journal of Clinical Periodontology, 42, 1060-1070. https://doi.org/10.1111/jcpe.12468
[15]
Moreira de Melo Jr., E.J. and Francischone, C.E. (2019) Three-Dimensional Finite Element Analysis of Two Angled Narrow-Diameter Implant Designs for an All-on-4 Prosthesis. Journal of Prosthetic Dentistry. (In Press) https://doi.org/10.1016/j.prosdent.2019.09.015
[16]
Velasco-Ortega, E., Flichy-Fernández, A., Punset, M., Jiménez-Guerra, A., Manero, J.M. and Gil, J. (2019) Fracture and Fatigue of Titanium Narrow Dental Implants: New Trends in Order to Improve the Mechanical Response. Materials, 12, 3728. https://doi.org/10.3390/ma12223728
[17]
Cordaro, L., Torsello, F., Mirisola Di Torresanto, V. and Rossini, C. (2006) Retrospective Evaluation of Mandibular Incisor Replacement with Narrow Neck Implants. Clinical Oral Implants Research, 17, 730-735. https://doi.org/10.1111/j.1600-0501.2006.01276.x
[18]
Polizzi, G., Fabbro, S., Furri, M., Herrmann, I. and Squarzoni, S. (1999) Clinical Application of Narrow Brånemark System Implants for Single-Tooth Restorations. The International Journal of Oral & Maxillofacial Implants, 14, 496-503.
[19]
Romeo, E., Lops, D., Amorfini, L., Chiapasco, M., Ghisolfi, M. and Vogel, G. (2006) Clinical and Radiographic Evaluation of Small-Diameter (3.3-mm) Implants Followed for 1-7 Years: A Longitudinal Study. Clinical Oral Implants Research, 17, 139-148. https://doi.org/10.1111/j.1600-0501.2005.01191.x
[20]
Wadia, R. (2019) Narrow-Diameter Implants. British Dental Journal, 226, 575. https://doi.org/10.1038/s41415-019-0266-y
[21]
Anitua, E., Errazquin, J.M., de Pedro, J., Barrio, P., Begoña, L. and Orive, G. (2010) Clinical Evaluation of Tiny® 2.5- and 3.0-mm Narrow-Diameter Implants as Definitive Implants in Different Clinical Situations: A Retrospective Cohort Study. European Journal of Oral Implantology, 3, 315-322.
[22]
Arisan, V., Bölükbaşi, N., Ersanli, S. and Ozdemir, T. (2010) Evaluation of 316 Narrow-Diameter Implants Followed for 5-10 Years: A Clinical and Radiographic Retrospective Study. Clinical Oral Implants Research, 21, 296-307. https://doi.org/10.1111/j.1600-0501.2009.01840.x
[23]
Froum, S.J., Shi, Y., Fisselier, F. and Cho, S.C. (2017) Long-Term Retrospective Evaluation of Success of Narrow-Diameter Implants in Esthetic Areas: A Consecutive Case Series with 3 to 14 Years Follow-Up. International Journal of Periodontics & Restorative Dentistry, 37, 629-637. https://doi.org/10.11607/prd.3266
[24]
Trbakovic, A., Bongenhielm, U. and Thor, A. (2018) A Clinical and Radiological Long-Term Follow-Up Study of Narrow-Diameter Implants in the Aesthetic Area. Clinical Implant Dentistry and Related Research, 20, 598-605. https://doi.org/10.1111/cid.12627
[25]
Pommer, B., Mailath-Pokorny, G., Haas, R., Buseniechner, D., Millesi, W. and Fürhauser, R. (2018) Extra-Short (<7 mm) and Extra-Narrow-Diameter (<3.5mm) Implants: A Meta-Analytic Literature Review. European Journal of Oral Implantology, 11, S137-S146.
[26]
Parize, H.N., Bohner, L.O.L., Gama, L.T., Porporatti, A.L., Mezzomo, L.A.M., Martin, W.C. and Gonçalves, T.M.S.V. (2019) Narrow-Diameter Implants in the Anterior Region: A Meta-Analysis. The International Journal of Oral & Maxillofacial Implants, 34, 1347-1358. https://doi.org/10.11607/jomi.7526
[27]
Yang, G., Chen, L., Gao, Y., Liu, H., Dong, H. and Mou, Y. (2019) Risk Factors and Reoperative Survival Rate of Failed Narrow-Diameter Implants in the Maxillary Anterior Region. Clinical Implant Dentistry and Related Research, 22, 29-41. https://doi.org/10.1111/cid.12867