- 2017
电容电导传感器油水两相流含率测量
|
Abstract:
摘要 在油水两相流测量中,利用电容传感器和电导传感器在含率测量上有不同的敏感范围,设计一种电容电导传感器,使用电子开关实现两种测量方法的快速切换,使其在相同敏感场内测量。新型电容电导传感器实现了对水平管道内低电导率水(自来水)组成的油水两相流的全含率范围的测量,利用快关阀进行标定,其含率测量误差小于±5% 。
[1] | Jaworek A, Krupa A. Gas/liquid ratio measurements by RF resonance capacitance sensor[J]. Sensors and Actuators A:Physical, 2004, 113(2):133-139. |
[2] | Wu H, Tan C, Dong X, et al. Design of a conductance and capacitance combination sensor for water holdup measurement in oil-water two-phase flow[J]. Flow Measurement and Instrumentation, 2015, 46(B):218-229. |
[3] | 董虓霄,谭超,董峰.油水两相流含水率测量组合传感器[J].工程热物理学报,2015,36(7):1487-1491. |
[4] | Xie C G, Reinecke N, Beck M S, et al. Electrical tomography techniques for process engineering applications[J]. The Chemical Engineering Journal and the Biochemical Engineering Journal, 1995, 56(3):127-133. |
[5] | Zhao X, Lucas G P. Use of a novel dual-sensor probe array and electrical resistance tomography for characterization of the mean and time-dependent properties of inclined, bubbly oil-in-water pipe flows[J]. Measurement Science and Technology, 2011, 22(10):104012. |
[6] | Fossa M. Design and performance of a conductance probe for measuring the liquid fraction in two-phase gas-liquid flows[J]. Flow Measurement and Instrumentation, 1998, 9(2):103-109. |
[7] | Abouelwafa M S A, Kendall E J M. The use of capacitance sensors for phase percentage determination in multiphase pipelines[J]. IEEE Transactions on Instrumentation and Measurement, 1980, 29(1):24-27. |
[8] | 施艳艳,董峰,谭超.两相流测量中环形电导传感器特性研究[J].中国电机工程学报,2010,30(17):62-66. |
[9] | Yang W Q. Hardware design of electrical capacitance tomography systems[J]. Measurement Science and Technology, 1996, 7(3):225-232. |
[10] | Ismail I, Gamio J C, Bukhari S F, et al. Tomography for multi-phase flow measurement in the oil industry[J]. Flow Measurement and Instrumentation, 2005, 16(2):145-155. |
[11] | Trallero J L, Sarica C, Brill J P. A study of oil/water flow patterns in horizontal pipes[J]. SPE Production & Facilities, 1997, 12(3):165-172. |
[12] | Dong F, Liu X P, Deng X, et al. Identification of two-phase flow regimes in horizontal, inclined and vertical pipes[J]. Measurement Science and Technology, 2001, 12(8):1069-1075. |
[13] | Devia F, Fossa M. Design and optimisation of impedance probes for void fraction measurements[J]. Flow Measurement and Instrumentation, 2003, 14(4):139-149. |
[14] | Dang R R, Zhao D S, Li L P, et al. The flow measurement of multiphase flow based on the conductance sensor[J]. Modern Instrumentation, 2012, 1(4):35-40. |
[15] | Reis E D, Cunha D S. Experimental study on different configurations of capacitive sensors for measuring the volumetric concentration in two-phase flows[J]. Flow Measurement and Instrumentation, 2014, 37:127-134. |