第三代双源CT不同扫描模式抑制下颈部伪影的对比
Comparison on the suppression of the artifacts in lower neck artery examination by the third-generation dual-source CT in different scanning mode

DOI: 10.11778/j.jdxb.2018.02.008

Keywords: 颈部,双能量CT,肩关节,伪影,辐射剂量,噪声
cervical
,dual energy CT,shoulder,artifact,radiation dose,noise

Full-Text   Cite this paper   Add to My Lib

Abstract:

摘要 目的: 通过对比下颈部CT常规扫描、双能量模式扫描、无预设值CARE kV联合CARE Dose 4D自动控制曝光技术,探索下颈部CT扫描抑制伪影的个性化方案.方法: 随机选取进行下颈部CT检查的患者99例,分成3组,A组:固定千伏、毫安扫描;B组:无预设值CARE kV联合CARE Dose 4D自动控制曝光技术扫描;C组:双能量模式扫描,分别将图像质量评分、噪声值、信噪比及容积CT剂量指数进行对比.结果: C组图像质量评分(3.70±0.51)高于B组(3.36±0.50), P<0.05,B组图像质量评分(3.36±0.50)明显高于A组(3.00±0.59),P<0.01;B组容积CT剂量指数(6.38±1.40)mGY明显低于A组(9.29 mGY), P<0.01;A组容积CT剂量指数(9.29 mGY)明显低于C组(12.58±4.74)mGY, P<0.01; C组噪声值(7.51±2.29)明显低于A组(12.03±3.52)、B组(12.18±4.47),两者P<0.01;C组信噪比(7.57±2.20)明显高于A组(5.19±1.86)、B组(5.51±1.86), 两者P<0.01; A、B组噪声值、信噪比无明显统计学意义(分别为P=0.86,P=0.52).结论: 建议常规下颈部CT扫描使用无预设值CARE kV联合CARE Dose 4D自动控制曝光技术,可获得辐射剂量最低、图像质量较优的影像,而双能量扫描模式能更大程度抑制下颈部伪影,在诊断下颈部疑难病变、定位细微病灶时,或在征得病人同意的情况下,可使用双能量模式获得更高质量的影像.

References

[1]  李青青, 吴莉,江杰,等.CAREkV联合CAREDose4D技术降低颈部肿大淋巴结CT扫描的辐射剂量[J].中国医科大学学报,2016,45(1):48-52.
[2]  徐卓东. CARE kV-智能最佳kV扫描技术降低剂量的同时提高图像质量[J].中国医疗设备,2012,27(2):120-123.
[3]  XU Z D.CARE kV-Intelligent kV scanning technology can reduce the radiation dose while improving image quality[J]. Chinese medical equipment, 2012, 27(2):120-123.
[4]  LV R F,WANG T,BING J.The application of angle modulation-ray tube current technology in lower neck scanning[J]. Journal of china clinic medical imaging,2012,23(3):219-220.
[5]  吕仁峰,吕亚囡, 王拓,等.不同体位对下颈部CT图像质量的影响[J].实用放射学杂志,2011,27(10):1599-1600.
[6]  KALRA M K, MAHER M M, Toth T L, et al.Strategies for ct radiation dose optimization[J]. Radiolory,2004,230(3):619-628.
[7]  WILTING J,ZWARTKRUIS A,VAN LEEUWEN M S. A rational approach to dose reduction in CT:individualized scan protocols[J]. Eur Radiol,2001,11(12):2627-2632.
[8]  郭锬,周诚,陈涓,等.颈部能谱CT与常规CT扫描辐射剂量与图像质量的对比研究[J].中华放射学杂志,2015,49(4):279-282.
[9]  杜良国,黄博,杜梁.不同双源CT头颈部扫描模式对影像质量及辐射剂量的影响[J].中国继续医学教育,2016,8(33):71-72.
[10]  GUO Y,ZHOU C,CHEN J, et al.Comparative study of radiation dose and image quality between spectral CT scanning and conventional scanning on neck[J]. Chinese journal of radiology,2015,49(4):279-282.
[11]  DU L G,HUANG B,DU L.Effect of dual source ct in head and neck scanning mode on the image quality and radiation dose[J]. China continuing medical education,2016,8(33):71-72.
[12]  吕仁锋,王拓,邴晶.角度射线管电流调制技术在下颈部扫描中的应用[J].中国临床医学影像杂志,2012,23(3):219-220.
[13]  BARRETT J F, KEAT N.Artifacts in CT: recognition and avoidance[J].Radiographics,2004,24: 1679-1691.
[14]  中华放射学杂志编委会.头颈部CT、MR扫描规范指南(修改稿)[J].中华放射学杂志,2007,41(9):996.
[15]  Editorial Board of Chinese Radiology Journal. Head and neck CT、MR scanning guidelines (Revised)[J]. Chinese journal of radiology,2007,41(9):996.
[16]  LI Q Q,WU L,JIANG J, et al.Application of CARE kV combined with CARE Dose 4D technology to reduce the radiation dose in ct scanning of enlarged cervical lymph nodes[J]. Journal of china medical university, 2016,45(1):48-52.
[17]  LV R F,LV Y N,WANG T, et al.The effect of different position on the lower neck CT image quality[J]. Journal of practical radiology,2011,27(10):1599-1600.
[18]  S?DERBERG M,GUNNARSSON M. The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D[J]. Radiat Prot Dosimetry,2010,139(1-3):173-179.
[19]  卢光明,张龙江,金征宇,等.双能量CT临床应用指南[M].北京:人民卫生出版社,2015:6-31.
[20]  LU G M,ZHANG L J,JIN Z Y, et al.Clinical application guidelines of duel energy CTM].Beijing: People's medical publishing house,2015:6-31.
[21]  付珺,胡俊岭.颈部能谱CT与常规CT扫描辐射剂量与图像质量的差异分析[J].临床医学研究与实践,2016,1(2):48.
[22]  FU J,HU J L.Difference Analysis of Radiation Dose and Image Quality between Neck Energy spectrum CT and Conventional CT Scan[J].Clinical research and practice,2016,1(2):48.
[23]  International commission on radiological protection. 1990 Recommendations of the international commission on radiological protection.ICRP publication 60[R]. Oxford:Pergamon Press,1991.
[24]  International commission on radiological protection. 2007 recommendations of the international commission on radiological protection.ICRP publication 103[R]. Oxford:Pergamon Press,2007.
[25]  International commission on radiological protection. The impact of the 2007 recommendations of the international commission on radiological protection (ICRP) in medical applications[R].Munich:IFMBE Press,2009.
[26]  MENZEL H,SCHIBILLA H,TEUNEN D,et al.European guidelines on quality criteria for computed tomography[C]. Luxembourg:European commission,2000.
[27]  国家质量监督检验检疫总局.GB 18771·2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2003.
[28]  General administration of quality supervision, Inspection and quarantine of the people';s republic of china.GB 18771·2002 Basic standards for protection against ionizing radiation and for the safety of radiation sources[S].Beijing: Standards press of china,2003.
[29]  李琳,罗德红,余小多,等.头颈部多层螺旋CT低剂量扫描研究[J].中国肿瘤影像学杂志,2009,2(4):81-86.
[30]  LI L,LUO D H,YU X D, et al.The study of low dose scan with multislice helical ct in head and neck[J]. Chinese journal of oncoradiology,2009,2(4):81-86.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133