全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2018 

侧向层析技术标记物研究进展

DOI: doi:10.7507/1001-5515.201703005

Keywords: 侧向层析, 标记物, 胶体金, 纳米酶

Full-Text   Cite this paper   Add to My Lib

Abstract:

侧向层析技术以其简单、快速、灵敏、经济等优势广泛应用于即时检验、现场检验以及家庭自检中。合适的标记物的选择对整个实验的灵敏度起着重要作用。传统的标记物有胶体金、纳米硒以及纳米碳等,尤以胶体金最为常用。近年来新型标记物的出现,如量子点、纳米酶等,使得侧向层析有了进一步的发展,实现了从定性检测逐步向定量检测的转变。本文旨在介绍目前已有的侧向层析标记物,为侧向层析工作者筛选合适的标记物提供一定的研究依据

References

[1]  10. Li Shuqun, Song Juan, Yang Hong, et al. An immunochromatographic assay for rapid and direct detection of 3-amino-5-morpholino-2-oxazolidone (AMOZ) in meat and feed samples. J Sci Food Agric, 2014, 94(4): 760-767.
[2]  11. Hou Wanwan, Wang Shaohui, Wang Xiaolan, et al. Development of colloidal gold immunochromatographic strips for detection of riemerella anatipestifer. PLoS One, 2015, 10(3): e0122952.
[3]  12. 王志增. 三聚氰胺胶体硒快速检测试纸条的研制. 兰州: 兰州大学, 2014.
[4]  13. Posthuma-Trumpie G A, Wichers J H, Koets M, et al. Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays. Anal Bioanal Chem, 2012, 402(2): 593-600.
[5]  14. Huang Xiaolin, Aguilar Z P, Xu Hengyi, et al. Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review. Biosens Bioelectron, 2016, 75: 166-180.
[6]  15. Cui Y L, Hu D D, Fang Y, et al. Preparation and mechanism of Fe3O4/Au core/shell super-paramagnetic microspheres. Science in China Series B-chemistry, 2001, 44(4): 404-410.
[7]  16. 郭博阳, 马乐, 张梦丹, 等. 利用金磁微粒免疫化学发光技术检测高敏 C 反应蛋白. 细胞与分子免疫学杂志, 2015, 31(11): 1468-1472.
[8]  1. Wang Zhizeng, Zhi Dejuan, Zhao Yang, et al. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed. Int J Nanomedicine, 2014, 9(1): 1699-1707.
[9]  2. Song Liuwei, Wang Yingbin, Fang Linlin, et al. Rapid fluorescent lateral-flow immunoassay for hepatitis B virus genotyping. Anal Chem, 2015, 87(10): 5173-5180.
[10]  3. Teerinen T, Lappalainen T, Erho T. A paper-based lateral flow assay for morphine. Anal Bioanal Chem, 2014, 406(24): 5955-5965.
[11]  4. Liu Liqiang, Xing Changrui, Yan Huijuan, et al. Development of an ELISA and immunochromatographic strip for highly sensitive detection of microcystin-LR. Sensors, 2014, 14(8): 14672-14685.
[12]  5. Hu Jie, Wang Shuqi, Wang Lin, et al. Advances in paper-based point-of-care diagnostics. Biosens Bioelectron, 2014, 54(2): 585-597.
[13]  6. Hagstr?m A E V, Garvey G, Paterson A S, et al. Sensitive detection of norovirus using phage nanoparticle reporters in lateral-flow assay. PLoS One, 2015, 10(5): e0126571.
[14]  7. Shan Shan, Lai Weihua, Xiong Yonghua, et al. Novel strategies to enhance lateral flow immunoassay sensitivity for detecting foodborne pathogens. J Agric Food Chem, 2015, 63(3): 745-753.
[15]  8. Chandler J, Gurmin T, Robinson N. The place of gold in rapid tests. IVD Technol, 2000, 6(3): 37-49.
[16]  9. Meng Kai, Sun Wenjing, Zhao Peng, et al. Development of colloidal gold-based immunochromatographic assay for rapid detection of Mycoplasma suis in porcine plasma. Biosens Bioelectron, 2014, 55: 396-399.
[17]  17. Hui Wenli, Zhang Sinong, Zhang Chao, et al. A novel lateral flow assay based on GoldMag nanoparticles and its clinical applications for genotyping of MTHFR C677T polymorphisms. Nanoscale, 2016, 8(6): 3579-3587.
[18]  18. 韩文敏. 免疫检测荧光微球的制备和性能研究. 武汉: 华中科技大学, 2008.
[19]  19. Cheng Song, Yang Yajie, Ni Xiaoqin, et al. Fluorescent microspheres lateral flow assay for sensitive detection of the milk allergen casein. Food Agric Immunol, 2017, 28(6): 1017-1028.
[20]  20. Liu Daofeng, Huang Yanmei, Chen Minghui, et al. Rapid detection method for aflatoxin B-1 in soybean sauce based on fluorescent microspheres probe. Food Control, 2015, 50: 659-662.
[21]  21. Xie Quanyuan, Wu Yanhua, Xiong Qirong, et al. Advantages of fluorescent microspheres compared with colloidal gold as a label in immunochromatographic lateral flow assays. Biosens Bioelectron, 2014, 54(12): 262-265.
[22]  22. 杨久敏. 基于纳米量子点标记肿瘤标志物检测系统研究. 天津: 天津大学, 2012.
[23]  23. Chen Zhenhua, Liang Rongliang, Guo Xinxin, et al. Simultaneous quantitation of cytokeratin-19 fragment and carcinoembryonic antigen in human serum via quantum dot-doped nanoparticles. Biosens Bioelectron, 2017, 91: 60-65.
[24]  24. Quesada-González D, Merko?i A. Nanoparticle-based lateral flow biosensors. Biosens Bioelectron, 2015, 73(2): 47-63.
[25]  25. Foubert A, Beloglazova N V, De Saeger S. Comparative study of colloidal gold and quantum dots as labels for multiplex screening tests for multi-mycotoxin detection. Anal Chim Acta, 2017, 955: 48-57.
[26]  26. Bruno J G. Application of DNA aptamers and quantum dots to lateral flow test strips for detection of foodborne pathogens with improved sensitivity versus colloidal gold. Pathogens, 2014, 3(2): 341-355.
[27]  27. 赵瑾. 布鲁氏抗原快速检测 UTP 免疫层析试纸条的研制. 北京: 军事医学科学院疾病预防控制所, 2009.
[28]  28. Bobosha K, Tjon Kon Fat E M, van den Eeden S J, et al. Field-evaluation of a new lateral flow assay for detection of cellular and humoral immunity against Mycobacterium leprae. PLoS Negl Trop Dis, 2014, 8(5): e2845.
[29]  29. Das G K, Stark D T, Kennedy I M. Potential toxicity of up-converting nanoparticles encapsulated with a bilayer formed by ligand attraction. Langmuir, 2014, 30(27): 8167-8176.
[30]  30. Zhang Pingping, Liu Xiao, Wang Chengbin, et al. Evaluation of up-converting phosphor technology-based lateral flow strips for rapid detection of Bacillus anthracis spore, Brucella spp., and Yersinia pestis. PLoS One, 2014, 9(8): e105305.
[31]  31. Corstjens P L, de Dood C J, Priest J W, et al. Feasibility of a lateral flow test for neurocysticercosis using novel up-converting nanomaterials and a lightweight strip analyzer. PLoS Negl Trop Dis, 2014, 8(7): e2944.
[32]  32. Chen Yiping, Xianyu Y, Sun Jiashu, et al. One-step detection of pathogens and cancer biomarkers by the naked eye based on aggregation of immunomagnetic beads. Nanoscale, 2016, 8(2): 1100-1107.
[33]  33. Shukla S, Leem H, Kim M. Development of a liposome-based immunochromatographic strip assay for the detection of Salmonella. Anal Bioanal Chem, 2011, 401(8): 2581-2590.
[34]  34. Duan Demin, Fan Kelong, Zhang Dexi, et al. Nanozyme-strip for rapid local diagnosis of Ebola. Biosens Bioelectron, 2015, 74: 134-141.
[35]  35. Barnett J M, Wraith P, Kiely J, et al. An inexpensive, fast and sensitive quantitative lateral flow magneto-immunoassay for total prostate specific antigen. Biosensors, 2014, 4(3): 204-220.
[36]  36. Wang Dianbing, Tian Bo, Zhang Zhiping, et al. Detection of Bacillus anthracis spores by super-paramagnetic lateral-flow immunoassays based on "Road Closure". Biosens Bioelectron, 2015, 67: 608-614.
[37]  37. Gao Lizeng, Yan Xiyun. Nanozymes: an emerging field bridging nanotechnology and biology. Science China. Life sciences, 2016, 59(4): 400-402.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679