-  2015 

心排血量检测方法及进展

DOI: doi:10.7507/1001-5515.20150127

Keywords: 心排血量, 无创检测, 相关性

Full-Text   Cite this paper   Add to My Lib

Abstract:

心排血量作为心血管疾病诊断和治疗的重要指标之一, 能及时地反映心血管系统的状态, 从而对相关疾病的治疗起到指导作用。近年来与心排血量相关的检测技术得到了极大的关注, 尤其是微创和无创检测心排血量的方法。本文主要就各类无创检测方法的原理和近年来的发展情况进行了阐述, 对各种检测方法进行对比分析

References

[1]  1. ?刘聚伟, 何昆仑.新型无创心输出量监测仪在充血性心力衰竭中临床应用的研究进展[J].海军医学杂志, 2011, 32(1):60-62.
[2]  2. CECCHINI S, SCHENA E, SACCOMANDI P, et al. Cardiac output estimation in mechanically ventilated patients:A comparison between prolonged expiration method and thermodilution[C]//2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). San Diego, CA:2012:2708-2711.
[3]  3. CHEN Guo, MENG Lingzhong, ALEXANDER B, et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler[J]. J Clin Anesth, 2012, 24(4):275-283.
[4]  26. TAYLOR K, MANLHIOT C, MCCRINDLE B, et al. Poor accuracy of noninvasive cardiac output monitoring using bioimpedance cardiography[PhysioFlow?] compared to magnetic resonance imaging in pediatric patients[J]. Anesth Analg, 2012, 114(4):771-775.
[5]  4. MAUS T M, REBER B, BANKS D A, et al. Cardiac output determination from endotracheally measured impedance cardiography:clinical evaluation of endotracheal cardiac output monitor[J]. J Cardiothorac Vasc Anesth, 2011, 25(5):770-775.
[6]  16. YAMADA T, TSUTSUI M, SUGO Y, et al. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time:a comparison with intermittent bolus thermodilution cardiac output[J]. Anesth Analg, 2012, 115(1):82-87.
[7]  21. SCHULTZ M G, CLIMIE R E, NIKOLIC S B, et al. Reproducibility of cardiac output derived by impedance cardiography during postural changes and exercise[J]. Artery Res, 2012, 6(2):78-84.
[8]  22. IKARASHI A, NOGAWA M, YAMAKOSHI T, et al. An optimal spot-electrodes array for electrical impedance cardiography through determination of impedance mapping of a regional area along the medial line on the thorax[C]//28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2006. EMBS'06. New York:2006:3202-3205.
[9]  25. MAUS T M, REBER B, BANKS D A, et al. Cardiac output determination from endotracheally measured impedance cardiography:clinical evaluation of endotracheal cardiac output monitor[J]. J Cardiothorac Vasc Anesth, 2011, 25(5):770-775.
[10]  6. DEKONINCK P, STEENHAUT P, VAN MIEGHEM T, et al. Comparison of Doppler-based and three-dimensional methods for fetal cardiac output measurement[J]. Fetal Diagn Ther, 2012, 32(1-2):72-78.
[11]  7. 范晓华, 刘骥, 范勤, 等.快速输液条件下温度稀释法与动脉压法心输出量测定的比较[J].临床麻醉学杂志, 2012, 28(5):430-432.
[12]  8. SARACENI E, ROSSI S, PERSONA P, et al. Comparison of two methods for cardiac output measurement in critically ill patients[J]. Br J Anaesth, 2011, 106(5):690-694.
[13]  9. 王宏宇, 苏中宏, 史宏伟, 等.FloTrac/Vigileo系统在单肺通气心输出量监测中应用的探讨[J].临床麻醉学杂志, 2011, 27(8):758-759.
[14]  5. 吴齐英.高龄患者围术期应用超声心输出量监测仪的临床价值[J].中国老年学杂志, 2013, 33(5):1053-1055.
[15]  10. GASPARETTO N, CACCIAVILLANI L, VALENTE S. The accuracy of PiCCO? measurements in hypothermic post-cardiac arrest patients[J]. Anaesthesia, 2012, 67(9):1050-1051.
[16]  11. MOSLEHPOUR M, ZHANG Guanqun, MUKKAMALA R. Cardiac output monitoring by long time interval analysis of a radial arterial blood pressure waveform with correction for arterial compliance changes using pulse transit time[C]//2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. Boston, MA:2011:5496-5498.
[17]  12. DABANLOO N J, ADAEI F, NASRABADI A M. The performance of neural network in the estimation of cardiac output using arterial blood pressure waveforms[C]//2011 Computing in Cardiology. Hangzhou:2011:145-148.
[18]  13. GAMA DE ABREU M, WINKLER T, PAHLITZSCH T, et al. Performance of the partial CO2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions[J]. Crit Care Med, 2003, 31(2):543-551.
[19]  14. WIEGAND G, BINDER W, ULMER H, et al. Noninvasive cardiac output measurement at rest and during exercise in pediatric patients after interventional or surgical atrial septal defect closure[J]. Pediatr Cardiol, 2012, 33(7):1109-1114.
[20]  15. 李闪珠, 张珣.基于脉图的心输出量无创检测仪的研究[J].中国医疗器械杂志, 2011, 35(5):344-347.
[21]  17. SUGO Y, SAKAI T, TERAO M, et al. The comparison of a novel continuous cardiac output monitor based on pulse wave transit time and echo Doppler during exercise[C]//2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). San Diego, CA:2012:236-239.
[22]  18. 王昌军, 李福星.影响阻抗法测心输出量的参数及其临床应用[J].数理医药学杂志, 2008, 21(1):106-107.
[23]  19. BALLESTERO Y, LóPEZ-HERCE J, URBANO J, et al. Measurement of cardiac output in children by bioreactance[J]. Pediatr Cardiol, 2011, 32(4):469-472.
[24]  20. PETTER H, ERIK A, BJ?RN E, et al. Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution[J]. Clin Physiol Funct Imaging, 2011, 31(1):39-47.
[25]  23. 宋义林, 高树枚, 五十岚朗, 等.基于电阻抗法无拘束心排量检测的最佳电极配置[J].生物医学工程学杂志, 2011, 28(1):32-35, 57.
[26]  24. 宋义林, 高树枚, 五十岚朗, 等.采用点状电极进行无创性心输出量检测时胸部圆柱模型的适用性[J].生物医学工程学杂志, 2013, 30(4):684-691.
[27]  27. CHO S H, LEE J S, YI K H, et al. Device and method for monitoring cardiac output using impedance of both hands. European Patent:WO2010KR02676[P].2010-04-28.
[28]  28. FAGNOUL D, VINCENT J L, BACKER D D. Cardiac output measurements using the bioreactance technique in critically ill patients[J]. Crit Care, 2012, 16(6):460.