全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2016 

New LED light source system with uniform illumination for line-scan CCD imaging systems
New LED light source system with uniform illumination for line-scan CCD imaging systems

DOI: 10.15918/j.jbit1004-0579.201625.0417

Keywords: line-scan CCD uniform illumination white light LED coefficient of variation array light source color difference
line-scan CCD uniform illumination white light LED coefficient of variation array light source color difference

Full-Text   Cite this paper   Add to My Lib

Abstract:

A system with uniform light reflection in the inner surface within a horizontal 2/3 cylindrical structure for line-scan CCD of the print testing was designed. The design was based on diffuse reflection uniformity of the integrating sphere and requirement of the strip uniform illumination region. This system was called dome light. White light LED array light sources were used for uniform illumination. The LEDs were filtrated to composite array light source based on coefficient of variation of a single LED. The standard white board and SG color checkers were used in the line-scan CCD imaging experiments under the dome light and ordinary illumination light source. The average color difference (ΔE) of SG color checkers in CIELAB space was 2.091 under the dome light and 2.286 under ordinary illumination light source respectively. Experimental results indicate that the dome light can satisfy illumination uniformity and color rendering consistency for line-scan CCD and provide a standard light source for uniform calibration of different cameras.
A system with uniform light reflection in the inner surface within a horizontal 2/3 cylindrical structure for line-scan CCD of the print testing was designed. The design was based on diffuse reflection uniformity of the integrating sphere and requirement of the strip uniform illumination region. This system was called dome light. White light LED array light sources were used for uniform illumination. The LEDs were filtrated to composite array light source based on coefficient of variation of a single LED. The standard white board and SG color checkers were used in the line-scan CCD imaging experiments under the dome light and ordinary illumination light source. The average color difference (ΔE) of SG color checkers in CIELAB space was 2.091 under the dome light and 2.286 under ordinary illumination light source respectively. Experimental results indicate that the dome light can satisfy illumination uniformity and color rendering consistency for line-scan CCD and provide a standard light source for uniform calibration of different cameras.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133