基于FDS的电机线棒环氧云母绝缘电老化特性
Electrical ageing characteristics of epoxy-mica insulation of generator based on FDS

DOI: 10.13801/j.cnki.fhclxb.20161202.004

Keywords: 电老化,频域介电谱,定子线棒主绝缘,少胶模压,环氧云母复合绝缘
electrical aging
,frequency domain spectroscopy,main insulation of stator bar,resin-less molding,epoxy-mica insulation

Full-Text   Cite this paper   Add to My Lib

Abstract:

References

[1]  TAYLOR N, EDIN H. Stator end-winding currents in frequency-domain dielectric response measurements[J]. IEEE Dielectric and Electrical Insulation Society, 2010, 17(5):1489-1498.
[2]  杜振波, 刘诣, 张连星. 基于频域介电谱的变压器油纸绝缘老化机理研究[J]. 电工电气, 2012(12):6-11. DU Z B, LIU Y, ZHANG L X. Research on transformer oilpaper insulation aging machanism based on frequency domain spectrum[J]. Electrotechnics Electric, 2012(12):6-11(in Chinese).
[3]  SHAYEGANI A A, GOCKENBACH E, BORSI H, et al. Investigation on the transformation of time domain spectroscopy data to frequency domain data for impregnated pressboard to reduce measurement time[J]. Electrical Engineering, 2006, 89(1):11-20.
[4]  唐盼. 基于极化去极化电流法的变压器油纸绝缘状态研究[D]. 上海:上海交通大学, 2012. TANG P. Study of oil-paper insulation transformers' aging state based on PDC method[D]. Shanghai:Shanghai Jiao Tong University, 2012(in Chinese).
[5]  VOROS C, NEMETH B, CSEPES G, et al. Investigation of complex, in-homogenous insulation system with muliple time constant by recovery voltage measurement(RVM)[C]. Ottawa:Electrical Insulation Conference, 2013:35-39.
[6]  FARAHANI M, BORSI H, GOCKENBACH E. Dielectric spectroscopy in time and frequency domain on insulation system of high voltage rotating machines[C]. Toulouse:Proceedings of the 2004 IEEE International Conference on Solid Dielectrics, 2004:5-8.
[7]  姚森敬, 田杰, 汤明杰, 等. 基于频域介电谱法的变压器油纸绝缘套管受潮状况分析[J]. 南方电网技术, 2014, 8(4):53-55. YAO S J, TIAN J, TANG M J, et al. Study on moisture assessment of oil-paper insulation bushings based on frequency domain spectrum[J]. Southern Power System Technology, 2014, 8(4):53-55(in Chinese).
[8]  王晓剑, 彭倩, 刘君, 等. 基于最小二乘法的变压器油纸绝缘频域介电谱法的研究[J]. 绝缘材料, 2012, 45(4):64-72. WANG X J, PENG Q, LIU J, et al. Least square method-based frequency domain dielectric spectroscopy of oil-paper insulation for transformer[J]. Insulating Materials, 2012, 45(4):64-72(in Chinese).
[9]  段宗超, 吴广宁, 崔运光, 等. 铜类产物对油纸绝缘频域介电谱特性的影响[J]. 高压电器, 2014, 50(7):14-20. DUAN Z C, WU G N, CUI Y G, et al. Impacts of copper-based products on the characteristics of frequency domain dielectric spectroscopy of oil-paper insulation[J]. High Voltage Apparatus, 2014, 50(7):14-20(in Chinese).
[10]  SHAYEGANI A A, MOHSENI H, BORSI H, et al. Diagnostics of power transformers with dielectric response measurements[C]. IEEE International Power System Conference, Columbus, United States, 2005:1-8.
[11]  LUNDGAARD L E, LINHJELL D, HESTAD L O, et al. High frequency dielectric response of paper/oil insulation[C]. Futuroscope:IEEE 16 th International Conference on Dielectric Liquids, 2008:1-4.
[12]  FERNANDO M, NARANPANAWA W, RATHNAYAKE R, et al. Condition assessment of stator insulation during drying wetting and electrical aging[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2013, 20(6):2081-2090.
[13]  SUBOCZ J. Application of the FDS method for assessment of HV epoxy-mica-glass insulation[J]. Materials Science Poland, 2009, 27:1229-1236.
[14]  郝艳捧, 谢恒堃. 基于热重和红外光谱分析研究大电机定子线棒绝缘中环氧的老化过程[J]. 中国电机工程学报, 2008, 28(13):15-19. HAO Y P, XIE H K. Degradation behaviour of epoxy in stator insulation based on thermogravimetry and infrared spectrometry[J]. Proceedings of the Chinese Society for Electrical Engineering, 2008, 28(13):15-19(in Chinese).
[15]  杜林.大电机主绝缘局部放电测量及老化特征研究[D]. 重庆:重庆大学, 2004. DU L. Study on measurement of partial discharge in large generator stator winding insulation and its aging characteristics[D]. Chongqing:College of Electrical Engineering Chongqing University, 2004(in Chinese).
[16]  付强, 孔繁荣, 陈庆国. 桐马环氧玻璃丝粉云母绝缘材料的耐盐雾湿热老化特性[J]. 复合材料学报, 2014, 31(3):851-858. FU Q, KONG F R, CHEN Q G. Ageing characteristics of tong-ma epoxy glass fiber power mica insulation materials under salt spray and humidity thermal condition[J]. Acta Materiae Compositae Sinica, 2014, 31(3):851-858(in Chinese).
[17]  关玉薇, 张连彬, 徐冰, 等. 大型水轮发电机环氧粉云母绝缘的老化诊断和寿命预测[J]. 大电机技术杂志, 1998, 2:26-30. GUAN Y W, ZHANG L B, XU B, et al. Deterioration diagnosis and life estimation of epoxy-mica paper insulation on large hydrogenerators[J]. Large Electric Machine and Hydraulic Turbine, 1998, 2:26-30(in Chinese).
[18]  SUMEREDER C, WOSCHITZ R, MUHR M. Polarization-depolarization measurements at insulation systems for rotating machines[J]. International Symposium on Electrical Insulating Materials, 2005, 3:706-709.
[19]  BOINARD P, PETHRICK R A, BANKS W M, et al. Non destructive evaluation of adhesively bonded composite structures using high frequency dielectric spectroscopy[J]. Journal of Materials Science, 2000, 35(6):1331-1337.
[20]  郝艳捧, 谢恒堃. 红外光谱法研究运行23年大电机定子线棒主绝缘中环氧的老化机理[J]. 电工技术学报, 2008, 23(3):19-23. HAO Y P, XIE H K. Degradation behavior of epoxy in stator insulation of large generators in service for 23 years based on infrared spectrometric analysis[J]. Transactions of China Electrotechnical Society, 2008, 23(3):19-23(in Chinese).