- 2015
双钢管高强混凝土短柱偏心受压性能试验
|
Abstract:
通过偏心率为0.2~0.6、 截面尺寸为180mm×180mm、 高度为600mm的16个试件的静力试验,研究了外方内圆双钢管高强混凝土短柱的偏心受压性能。试验结果表明: 试件的破坏形态为整体弯曲及方钢管壁板局部鼓曲,剩余轴压力为峰值轴压力的75%以上; 增大方钢管含钢率或增大偏心率,双钢管高强混凝土短柱偏心受压承载力增大。采用叠加法计算得到的双钢管高强混凝土短柱试件的偏心受压承载力,与试验结果符合良好。
Abstract: Static tests were conducted on 16 high strength concrete filled double-tube (CFDT) short column specimens with eccentricity ratios 0.2-0.6. The tests studied the eccentric compressive behavior of the CFDT short columns. All the specimens had identical section dimensions of 180 mm×180 mm and heights of 600 mm. The test results indicate that all the specimens failed in bending of the column and local buckling of the steel plates of the external square tube. The residual compressive force is larger than 75% of the maximum compressive force. Increasing the steel ratio of the square steel tube or the eccentricity ratio of the compressive load increases the eccentric compressive capacity of the CFDT short columns. The eccentric compressive capacity of the specimens calculated by the superposition method agrees well with the test results.