|
- 2018
半导体激光美白程序对牙髓组织中降钙素相关肽和5-羟色胺的影响及意义
|
Abstract:
摘要 目的:观察在半导体激光美白程序使用连续频率和间断频率照射大鼠磨牙,观察不同时段牙髓组织中的降钙素相关肽(calcitonin gene-related peptide,CGRP)和5-羟色胺(5-hydroxytryptamine,5-HT)表达的变化,为半导体美白时的牙髓保护提供技术参考。方法: 3月龄SD雄性大鼠随机分为正常组(A组)、半导体激光美白连续频率组(B组)、半导体激光美白间断频率组(C组);B组选择半导体激光美白中的7 W、20 Hz、15 s连续频率照射大鼠上颌第一、二磨牙,术后即刻(B0组)、1 d(B1组)、3 d(B3组)、7 d(B7组)处死大鼠;C组选择半导体激光美白中的7 W、20 Hz、30 s、1/2间断频率照射大鼠上颌第一、二磨牙,术后即刻(C0组)、1 d(C1组)、3 d(C3组)、7 d(C7组)处死大鼠;取大鼠上颌第一、二磨牙制作组织切片,免疫组织化学法检测牙髓组织中CGRP、5-HT的变化。结果:牙髓组织中CGRP、5-HT的表达在B、C各组均高于A组;从术后即刻开始升高,3 d达最高,然后开始降低;相同时段比较B组高于C组。结论:连续频率和间断频率半导体激光美白时,有效时间相同连续频率的刺激性显著高于间断频率,间断频率为首选;同时,激光照射即刻到3 d牙髓组织中疼痛递质表达不断升高,应加强牙髓的保护,减少牙髓的刺激因素
[1] | Spradley JM, Davoodi A, Gee LB, et al. Differences in peripheral endocannabinoid modulation of scratching behavior in facial vs. spinally-innervated skin [J]. Neuropharmacology,2012,63(4)∶743-749 |
[2] | Wang W, Zhu Y, Li J, et al. Efficacy of cold light bleaching using different bleaching times and their effects on human enamel [J]. Dent Mater J,2013,32(5)∶761-766 |
[3] | Mirzaie M, Yassini E, Ganji S, et al. A comparative study of enamel surface roughness after bleaching with diode laser and nd: YAG laser [J]. J Lasers Med Sci,2016,7(3)∶197-200 |
[4] | 刘伟,陈杰,胡开进,等.负载GPRS及SP的明胶缓释微球用于修复家兔骨质疏松模型骨缺损的研究[J].口腔医学研究,2016,32(3)∶228-232 |
[5] | Su YS, Mei HR, Wang CH, et al. Peripheral 5-HT mediates mirror-image pain by a cross-talk with acid-sensing ion channel 3 [J]. Neuropharmacology,2017,130∶92-104 |
[6] | Ohnami S, Kato A, Ogawa K, et al. Effects of milnacipran, a 5-HT and noradrenaline reuptake inhibitor, on C-fibre-evoked field potentials in spinal long-term potentiation and neuropathic pain [J]. Br J Pharmacol,2012,167(3)∶537-547 |
[7] | Morgan S, Jum'ah AA, Brunton P. Assessment of efficacy and post-bleaching sensitivity of home bleaching using 10% carbamide peroxide in extended and non-extended bleaching trays [J]. Br Dent J,2015,218(10)∶579-582 |
[8] | Dionysopoulos D, Strakas D, Koliniotou-Koumpia E, et al. Effect of Er,Cr:YSGG laser irradiation on bovine enamel surface during in-office tooth bleaching <i>ex vivo</i> [J]. Odontology,2017,105(3)∶320-328 |
[9] | 徐彦彬,李春年.半导体激光美白术的临床疗效比较[J].河北医药杂志,2016,38(19)∶2964-2966 |
[10] | 李源静,杨岚,李倩倩,等.降钙素基因相关肽对成骨细胞OPN表达的影响[J].口腔医学研究,2016,32(11)∶1137-1140 |
[11] | Santos CM, Francischi JN, Lima-Paiva P, et al. Effect of transcutaneous electrical stimulation on nociception and edema induced by peripheral serotonin [J]. Int J Neurosci, 2013,123(7)∶507-515 |
[12] | Zhao K, Zong L, Zhang Q, et al. Clinical comparison between two bleaching techniques: a 180-day follow-up study [J]. Quintessence Int, 2013, 44(8)∶601-607 |
[13] | De Moor RJ, Verheyen J, Verheyen P, et al. Laser teeth bleaching: evaluation of eventual side effects on enamel and the pulp and the efficiency <i>in vitro</i> and <i>in vivo</i> [J]. ScientificWorldJournal,2015,2015∶835405 |