|
- 2015
尖牙远中微植体支抗植入区域口腔颌面部锥形束CT测量分析
|
Abstract:
摘要 目的:通过测量上、下颌骨尖牙与第一前磨牙之间不同水平处颊侧骨皮质的厚度以及根间距离,为微植体支抗植入的最佳位点提供依据。方法:随机选择武汉大学口腔医院就诊患者的口腔颌面部锥形束CT影像资料29例,测量双侧上、下颌骨尖牙与第一前磨牙间距离牙槽嵴顶3 mm、4 mm、5 mm、6 mm、7 mm不同水平处颊侧骨皮质的厚度及根间距离,并对测量数据进行统计分析。结果:上下颌尖牙与第一前磨牙间3~7 mm水平骨皮质厚度均大于1 mm,上颌自3 mm向根尖骨皮质厚度逐渐增加,下颌4 mm处骨皮质最薄,自5 mm向根尖方向骨皮质厚度逐渐增加。上下颌尖牙与第一前磨牙间3~7 mm水平牙根间距均大于2 mm,上、下颌骨距牙槽嵴顶3 mm处牙根间距最短,向根尖方向根间距离逐渐增大;双侧上下颌骨3~7 mm各水平骨皮质厚度及根间距离的差异没有统计学意义。结论:上下颌尖牙远中区在距离牙槽嵴顶≥3 mm处骨质可作为微植体的安全植入区域;通过口腔颌面部锥形束CT对微植体植入区域骨皮质厚度及根间距离的测量分析,可以向临床提供精确的数据支持
[1] | 衡士超,程勇,李波,等.锥形束CT结合simplant软件在颌面部三维测量中的初步研究[J].口腔医学研究,2011,01:60-63 |
[2] | Feng P, Kau CH, Hong Z, et al. The anatomical evaluation of the dental arches using cone beam computed tomography - an investigation of the availability of bone for placement of mini-screws [J]. Head Face Med, 2013, 9(1)∶13 |
[3] | Park HS, Kwon OW, Sung JH. Nonextraction treatment of an open bite with microscrew implant anchorage [J]. Am J Orthod Dentofacial Orthop, 2006, 130(3)∶391-402 |
[4] | Watanabe H, Deguchi T, Hasegawa, M, et al. Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density [J]. Orthod Craniofac Res, 2013, 16(1)∶44-55 |
[5] | Lim JE, Lee SJ, Kim YJ, et al. Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement [J]. Orthod Craniofac Res, 2009, 12(4)∶299-304 |
[6] | Motoyoshi M, Yoshida T, Ono A, et al. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants [J]. Int J Oral Maxillofac Implants, 2007, 22(5)∶779-84 |
[7] | Park J, Cho HJ. Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults [J]. Am J Orthod Dentofacial Orthop, 2009, 136(3)∶314 e1-12; discussion 314-5 |
[8] | Papageorgiou SN, Zogakis IP, Papadopoulos MA. Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis [J]. Am J Orthod Dentofacial Orthop, 2012, 142(5)∶577-595 e7 |
[9] | Topouzelis, N., P. Tsaousoglou. Clinical factors correlated with the success rate of miniscrews in orthodontic treatment [J]. Int J Oral Sci, 2012, 4(1)∶38-44 |
[10] | Timock, A. M., V. Cook, T. McDonald, et al. Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging [J]. Am J Orthod Dentofacial Orthop, 2011, 140(5)∶734-44 |
[11] | Baumgaertel S, Hans MG. Buccal cortical bone thickness for mini-implant placement [J]. Am J Orthod Dentofacial Orthop, 2009, 136(2)∶230-5 |