全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
-  2015 

利用分段水喷雾系统对长大隧道进行分区保护的试验研究 Experimental study of using water mist segment as a fire compartment in tunnels

Keywords: 分段水喷雾,隧道,火灾,温度,烟气

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对长大隧道提出一种分段水喷雾方法对隧道进行保护,即每隔350m左右设置一小段喷雾系统,火灾时开启对应区段两端的喷雾系统,利用喷雾区段的过滤作用阻止烟气向上下游扩散,保证区段外环境的相对安全,从而有利于人员逃生.利用10∶1模型试验和实体隧道火灾实验证明水喷雾段可以有效降低隧道温度,阻止烟气及热量向下游传播,水喷雾压力越大喷雾粒径越小,越有利于隧道降温作用,对隧道分区防护作用越明显;分段水喷雾流量和喷头不同布置对阻止烟气向下游扩散作用不明显,通风虽然会削弱水喷雾段对烟气扩散的阻止作用,但不妨碍其在隧道中的应用

References

[1]  Nele Tilley,Pieter Rauwoens,Bart Merci.Verification of the accuracy of CFD simulations in small-scale tunnel and atrium fire configurations[J].Fire Safety Journal,2011,46(4):186-193.
[2]  World Road Association(PIARC).Fire and Smoke Control in Road Tunnels[S].PIARC Committee on Road Tunnels(C5),Publication 05.05.B,2004.
[3]  Carvel R,Beard A.The Handbook of Tunnel Fire Safety[M].London:Thomas Telford,2005:3-23.
[4]  Hu L H,Liu S,Peng W,et al.Experimental study on burning rates of square/rectangular gasoline and methanol pool fires under longitudinal air flow in a wind tunnel[J].Journal of Hazardous Materials,2009,169(1):972-979.
[5]  Drysdale D.An Introduction to Fire Dynamics[M].New Jersey:Wiley,2011.
[6]  Grant GB G,Brenton J,Drysdale D.Fire suppression by water sprays[J].Progress in Energy and Combustion Science,2000,26(2):79-130.
[7]  中国交通运输部综合规划司.交通概括[R].http://www.moc.gov.cn/zhuzhan/jiaotonggaikuang/201506/t20150601_1827431.html,2013-04-25.
[8]  Merci B,Shipp M.Smoke and heat control for fires in large car parks:Lessons learnt from research[J].Fire Safety Journal,2013,(57):3-10.
[9]  Wu Y,Bakar M Z A.Control of smoke flow in tunnel fires using longitudinal ventilation systems—a study of the critical velocity[J].Fire Safety Journal,2000,35(4):363-390.
[10]  袁建平,方正,程彩霞,等.隧道火灾时拱顶最高烟气温度的实验研究[J].地下空间与工程学,2010,(5),1094-1097.
[11]  伍作朋,吴丽琼.火灾模化与相似理论[J].消防科技,1997,(3):7-9.

Full-Text