-  2018 

干式空心并联电抗器过热性故障温度场耦合计算与分析 Coupling calculation and analysis of temperature field of dry-type air-core shunt reactor during overheat fault

Keywords: 干式空心并联电抗器,过热性故障,温度场,多场耦合

Full-Text   Cite this paper   Add to My Lib

Abstract:

干式空心并联电抗器出现过热性故障影响设备的正常使用寿命,为计算分析干式空心并联电抗器过热性故障温度场分布,基于多场耦合有限元理论,建立了干式空心并联电抗器流体-温度场耦合计算模型,得出干式空心并联电抗器正常运行时的温度场分布,并与现场运行实测的温度作对比,验证了计算模型的准确性.利用验证的流体-温度场耦合计算模型,计算了干式空心并联电抗器出现不同程度过热性故障下的温度场分布,分析了包封轴向、故障位置径向和顶部径向温度变化规律.分析结果表明,通过监测电抗器顶部温度变化,可以有效反映干式空心并联电抗器运行中的过热性故障

References

[1]  叶占刚.干式空心电抗器的温升试验与绕组温升的计算[J].变压器,1999,(9):6-12.Ye Zhangang.Temperature rise test of dry-type aircore reactor and calculation of its winding temperature rise[J].Transformer,1999,(9):6-12.
[2]  Deng Qiu,Li Zhenbiao,Yin Xiaozhen,et al.Steady thermal field simulation of forced air-cooled columntype air-core reactor[J].High Voltage Engineering,2013,39(4):839-844.
[3]  聂喜玲,黎大健,赵坚.干式空心电抗器损坏原因分析及对策[J].广西电力,2013,36(2):29-31.Nie Xiling,Li Dajian,Zhao Jian.Analysis and countermeasures of dry type air core reactor damage[J].Guangxi Electric Power,2013,36(2):29-31.
[4]  王瑞科,郭香福.干式空心电抗器匝间绝缘故障对总体特性的影响及检测方法[J].变压器,2000,37(9):32-35.Wang Ruike,Guo Xiangfu.Influence of turn to turn insulation fault of dry-type air-core reactor on overall characteristics and detection method[J].Transformer,2000,37(9):32-35.
[5]  中华人民共和国国家质量监督检验检疫总局.GB/T1094.12—2013干式电力变压器负载导则[S].北京:中国标准出版社,2013.State Quality Supervision and Inspection and Quarantine Bureau of the People’s Republic of China.GB/T1094.12-2013 Dry Type Power Transformer Load Guide[S].Beijing:China Standard Press,2013.
[6]  崔志刚.干式空心并联电抗器故障原因分析探讨[J].变压器,2012,49(3):61-63.Cui Zhigang.Analysis and discussion on fault in drytype shunt reactor with air core[J].Transformer,2012,49(3):61-63.
[7]  苗俊杰,姜庆礼.500kV变电站35kV干式电抗器故障分析[J].电力电容器与无功补偿,2012,33(2):65-69.Miao Junjie,Jiang Qingli.Fault analysis of a 35kV drytype reactor in 500kV substation[J].Power Capacitor&Reactive Power Compensation,2012,33(2):65-69.
[8]  夏天伟,曹云东,金巍,等.干式空心电抗器温度场分析[J].高电压技术,1999,25(4):86-88.Xia Tianwei,Cao Yundong,Jin Wei,et al.The analysis of temperature field in dry air core reactor[J].High Voltage Engineering,1999,25(4):86-88.
[9]  刘志刚,耿英三,王建华,等.基于流场-温度场耦合计算的新型空心电抗器设计与分析[J].电工技术学报,2003,18(6):59-63.Liu Zhigang,Geng Yingsan,Wang Jianhua,et al.Design and analysis of new type air-core reactor based on coupled fluid thermal field calculation[J].Transactions of China Electrotechnical Society,2003,18(6):59-63.
[10]  阎秀恪,代忠滨,于存湛,等.基于全损耗计算的空心电力电抗器温度场研究[J].电工电能新技术,2015,34(4):31-36.Yan Xiuke,Dai Zhongbin,Yu Cunzhan,et al.Research on temperature field of air core power reactor based on all losses calculation[J].Advanced Technology of Electrical Engineering and Energy,2015,34(4):31-36.
[11]  李晶,满家健,周电波,等.金属封闭高压开关柜手车触头温度场仿真分析及实验研究[J].高压电器,2015,(8):74-79.Li Jing,Man Jiajian,Zhou Dianbo,et al.Simulation analysis and experimental research on temperature distribution of metalenclosed high voltage switchgear handcart contactor[J].High Voltage Apparatus,2015,(8):74-79.
[12]  王艳武,杨立,孙丰瑞.异步电动机定子绕组匝间短路三维温度场计算与分析[J].中国电机工程学报,2009,(24):84-90.Wang Yanwu,Yang Li,Sun Fengrui.Simulation and analysis of 3D temperature field for stator winding short-circuit in asynchronous motor[J].Proceedings of the CSEE,2009,(24):84-90.
[13]  杨世铭,陶文铨.传热学[M].第4版.北京:高等教育出版社,2010:41-46.Yang Shiming,Tao Wenquan.Numerical Heat Transfer[M].4th editon.Beijing:Higher Education Press,2010:41-46.
[14]  王耀龙.干式空心并联电抗器多起损坏原因分析[J].电气技术,2012,(7):55-57.Wang Yaolong.Analysis of dry-type air core shunt reactor fault cases[J].Electrical Engineering,2012,(7):55-57.
[15]  姜志鹏,文习山,王羽,等.特高压干式空心平波电抗器温度场耦合计算与试验[J].中国电机工程学报,2015,35(20):5344-5350.Jiang Zhipeng,Wen Xishan,Wang Yu,et al.Test and coupling calculation of temperature field for UHV dry-type air-core smoothing reactor[J].Proceedings of the CSEE,2015,35(20):5344-5350.

Full-Text