-  2017 

基于热流管单元的混凝土通风冷却效果 Concrete cooling effect by air cooling based on heat-fluid pipe element

Keywords: 混凝土,通水冷却,通风冷却,热流耦合管

Full-Text   Cite this paper   Add to My Lib

Abstract:

我国当前通常采用内嵌水管通水冷却以降低混凝土温度,但在干旱地区或混凝土结构较高部分采用通水冷却施工较不方便,以空气作为冷却介质进行混凝土冷却能够较好地避免上述问题.相较于通水冷却,通风冷却施工设备较为简单,且由于空气密度较小,可采用竖直方向通风冷却.采用热流耦合单元,充分考虑风、水的沿程温度变化以及冷却管附近混凝土、远离冷却管混凝土不同的温度变化规律,进行通风冷却敏感性分析及通风冷却、通水冷却效果对比.仿真模拟结果表明:通风冷却能够较好地削减混凝土温度峰值;通风风速越快、通风温度越低、混凝土截面越小,通风冷却效果越好;选取适当的风速及通风温度,通风冷却能够达到与通水冷却近似的冷却效果

References

[1]  McAdams W H.Heat Transmission[M].3rd ed.New York:McGraw-Hill,1954.
[2]  张勇.大体积混凝土风冷却技术研究与应用[J].中国建设信息,2010,(7):81-83.Zhang Yong.Research and application of mass concrete air cooling technology[J].Information of China Construction,2010,(7):81-83.
[3]  Hedlund H,Groth P.Air cooling of concrete by means of embedded cooling pipes—Part I:Laboratory tests of heat transfer coefficients[J].Materials and Structures,1998,31(5):329-334.
[4]  Groth P,Hedlund H.Air cooling of concrete by means of embedded cooling pipes—Part II:Application in design[J].Materials and Structures,1998,31(6):387-392.
[5]  Ishikawa S,Matsukawa K,Nakanishi S,et al.Air pipe cooling system[J].Concrete International,2007,29:45-49.
[6]  Azenha M,Lameiras R,de Sousa C,et al.Application of air cooled pipes for reduction of early age cracking risk in a massive RC wall[J].Engineering Structures,2014,62:148-163.
[7]  Liu X,Duan Y,Zhou W,et al.Modeling the piped water cooling of a concrete dam using the heat-fluid coupling method[J].Journal of Engineering Mechanics,2012,139(9):1278-1289.
[8]  李梁,张超,张振洲,等.基于热流管单元的大体积混凝土一期冷却效果精细模拟[J].武汉大学学报(工学版),2013,46(4):442-448.Li Liang,Zhang Chao,Zhang Zhenzhou,et al.Refined simulation of first stage artificial cooling effect in mass concrete based on heat-fluid pipe element[J].Engineering Journal of Wuhan University,2013,46(4):442-448.
[9]  刘俊,黄玮,周伟,等.大体积混凝土小温差的长期通水冷却[J].武汉大学学报(工学版),2011,44(5):549-553.Liu Jun,Huang Wei,Zhou Wei,et al.Study of small temperature difference and long-term water cooling in mass concrete[J].Engineering Journal of Wuhan University,2011,44(5):549-553.
[10]  Liu Xinghong,Zhang Chao,Chang Xiaolin,et al.Precise simulation analysis of thermal field in mass concrete with pipe water cooling system[J].Applied Thermal Engineering,2015,78:449-459.
[11]  Dittus F W,Boelter L M K.Heat transfer in automobile radiators of the tubular type[J].International Communications in Heat and Mass Transfer,1985,12(1):3-22.
[12]  闫慧玉.大体积混凝土温度场水管冷却热流耦合仿真方法研究[D].武汉:武汉大学,2005.Yan Huiyu.Study on thermal-fluid method of water pipe cooling for the temperature field of mass concrete[D].Wuhan:Wuhan University,2005.
[13]  刘杏红,马刚,常晓林,等.基于热-流耦合精细算法的大体积混凝土水管冷却数值模拟[J].工程力学,2012,29(8):159-164.Liu Xinghong,Ma Gang,Chang Xiaolin,et al.The refined numerical simulation of pipe cooling in mass concrete based on heat-fluid coupling method[J].Engineering Mechanics,2012,29(8):159-164.
[14]  段寅,向正林,常晓林,等.大体积混凝土水管冷却热流耦合算法与等效算法对比分析[J].武汉大学学报(工学版),2010,43(6):703-707.Duan Yin,Xiang Zhengling,Chang Xiaolin,et al.Comparative analysis of pipe cooling in mass concrete using thermal fluid coupling method and equivalent method based on FEM[J].Engineering Journal of Wuhan University,2010,43(6):703-707.
[15]  朱伯芳.大体积混凝土温度应力与温度控制[M].北京:中国电力出版社,1999.Zhu Bofang.Thermal Stresses and Temperature Control of Mass Concrete[M].Beijing:China Electric Power Press,1999.