温度感知的高能效数据中心负载聚合算法 A Thermal-Aware Energy-Efficient Workload Consolidation Method in Data Centers

Keywords: 温度,冷却功耗,热力学仿真,负载聚合

Full-Text   Cite this paper   Add to My Lib

Abstract:

日益增长的数据中心冷却系统能耗会提升数据中心运行成本并带来巨大的碳排放,在数据中心轻载时进行负载聚合是降低系统能耗的有效途径.传统负载聚合只关注计算功耗的降低,而负载聚合会带来数据中心热点的产生和冷却功耗的增加.通过热力学仿真得到温度功耗模型;以一个实际云计算平台内的工作日志作为负载进行数据中心仿真,结果表明考虑节点热传递特性的聚合算法比起考虑迁移开销的聚合算法更能有较降低峰值温度和冷却功耗

References

[1]  LI S,LE H,PHAM N,et al.Joint Optimization of Computing and Cooling Energy:Analytic Model and Machine Room Case Study[DB/OL].[2016-05-06].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6258012.DOI:10.1109/ICDCS.2012.64.
[2]  RAGHAVENDRA R,RANGANATHAN P,TAL-WAR V,et al.No“Power”Struggles:Coordinated Multi-Level Power Management for the Data Center[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=1346289&CFID=918154871&CFTOKEN=29872260.DOI:10.1145/1346281.1346289.
[3]  ABBASI Z,VARSAMOPOULOS G,GUPTA S K S.Thermal Aware Server Provisioning and Workload Distribution for Internet Data Centers[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=1851493&CFID=918154871&CFTOKEN=29872260.DOI:10.1145/1851476.1851493.
[4]  BELADY C L.In the Data Center,Power and Cooling Costs More Than the It Equipment It Supports[EB/OL].[2016-08-14].http://www.electronics-cooling.com/2007/02/in-the-data-center-power-and-cooling-costs-more-than-the-it-equipment-it-supports/.
[5]  Intel.Dual-Core Intel?Xeon?Processor LV and ULVDatasheet[R/OL].[2016-10-02].http://www.intel.com/content/dam/www/public/us/en/documents/datasheets/dual-core-xeon-lv-ulv-datasheet.pdf.
[6]  GOIRI I,KATSAK W,LE K,et al.Parasol and Green Switch:Managing Datacenters Powered by Renewable Energy[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=2451123&CFID=918154871&CFTOKEN=29872260.DOI:10.1145/2490301.2451123.
[7]  DAN T,ETSION Y,FEITELSON D G.Backfilling using system generated predictions rather than user runtime estimates[J].IEEE Transactions on Parallel and Distributed Systems,2007,18(6):789-803.DOI:10.1109/TPDS.2007.70606.
[8]  CHEN T,YANG Y,ZHANG H,et al.Network energy saving technologies for green wireless access networks[J].IEEE Wireless Communications,2011,18(5):30-38.DOI:10.1109/MWC.2011.6056690.
[9]  RAMOS L,BIANCHINI R.C-Oracle:Predictive Thermal Management for Data Centers[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4658632.DOI:10.1109/HPCA.2008.4658632.
[10]  THIBODEAU P.Data Centers Are the New Polluters[EB/OL].[2017-03-28].http://www.computerworld.com/article/2598562/data-center/data-centersare-the-new-polluters.html.
[11]  GADOMSKI R.Reducing Energy Consumption and Cost in the Data Center[EB/OL].[2016-08-14].http://www.gartner.com/DisplayDocument?ref=clientFriendlyUrl&id=1818517.
[12]  RANGANATHAN P,LEECH P,IRWIN D,et al.Ensemble-Level Power Management for Dense Blade Servers[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=1136492&CFID=918154871&CFTOKEN=29872260.DOI:10.1109/ISCA.2006.20.
[13]  BRUNSCHWILER T,SMITH B,RUETSCHE E,et al.Toward zero emission data centers through direct reuse of thermal energy[J].IBM Journal of Research and Development,2009,53(3):1-13.DOI:10.1147/JRD.2009.5429024.
[14]  WANG X,CHEN M.Cluster-Level Feedback Power Control for Performance Optimization[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4658631.DOI:10.1109/HP-CA.2008.4658631.
[15]  WANG X,WANG Y.Coordinating power control and performance management for virtualized server clusters[J].IEEE Trans on Parallel and Distributed Systems,2011,22(2):245-259.DOI:10.1109/TPDS.2010.91.
[16]  MOORE J,CHASE J,PARTHASARATHY R,et al.Making Scheduling Cool:Temperature-Aware Resource Assignment in Data Centers[DB/OL].[2016-05-09].https://www.usenix.org/legacy/event/usenix05/tech/general/full_papers/moore/moore.pdf.
[17]  HSU C H,POOLE S W.Power Signature Analysis of the SPECpower_ssj2008Benchmark[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5762739.DOI:10.1109/ISPASS.2011.5762739.
[18]  JONAS M,GILBERT R R,FERGUSON J,et al.ATransient Model for Data Center Thermal Prediction[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6322262.DOI:10.1109/IGCC.2012.6322262.
[19]  叶如钢.CFD仿真建模技术在数据中心机房节能中的应用[J].节能环保,2015,4:244-245.YE R G.The application of CFD simulation technology the machine rooms of a data center[J].Energy Reduction and Environmental Protection,2015,4:244-245(Ch).
[20]  STRUNK A,DARGIE W.Does Live Migration of Virtual Machines Cost Energy[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6531798.DOI:10.1109/AINA.2013.137.
[21]  CHEN Y,GMACH D,HYSER C,et al.Integrated Management of Application Performance,Power and Cooling in Data Centers[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5488433.DOI:10.1109/NOMS.2010.5488433.
[22]  MANZANARES A,QIN X,RUAN X,et al.PRE-BUD:Prefetching for energy-efficient parallel I/O systems with buffer disks[J].ACM Transactions on Storage,2011,7(1):1-29.DOI:10.1145/1970343.1970346.
[23]  MILLER R.Data Centers Move to Cut Water Waste[EB/OL].[2016-08-14].http://www.datacenterknowledge.com/archives/2009/04/09/data-centers-moveto-cut-water-waste/.
[24]  LI L,LIANG C J M,LIU J.ThermoCast:A CyberPhysical Forecasting Model for Data Centers[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=2020611&CFID=918154871&CFTOKEN=29872260.DOI:10.1145/2020408.2020611.
[25]  PAROLINI L,SINOPOLI B,KROGH B H,et al.ACyber-Physical-System Approach to Data Center Modeling and Control for Energy Efficiency[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6006498.DOI:10.1109/JPROC.2011.2161244.
[26]  BREEN T J,WALSH E,PUNCH J,et al.From Chip to Cooling Tower Data Center modeling:PartⅠInfluence of Server Inlet Temperature and Temperature Rise across Cabinet[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5501421.DOI:10.1109/ITHERM.2010.5501421.
[27]  WANG D,REN C,SIVASUBRAMANIAM A.Virtualizing Power Distribution in Datacenters[DB/OL].[2016-05-02].http://dl.acm.org/citation.cfm?id=2485973&CFID=918154871&CFTOKEN=29872260.DOI:10.1145/2485922.2485973.
[28]  MILLER R.Uptime Institute:The Average PUE is1.8[EB/OL].[2016-08-14].http://www.datacenterknowledge.com/archives/2011/05/10/uptime-institute-the-average-pue-is-1-8/.
[29]  CHOI J,KIM Y,SIVASUBRANMANIAM A.Modeling and Managing Thermal Profiles of Rack-mounted Servers with ThermoStat[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4147661.DOI:10.1109/HPCA.2007.346198.
[30]  TANG Q,GUPTA S K S,VARSAMOPOULOS G.Energy-efficient thermal aware task scheduling for homogeneous high-performance computing data centers:A cyber-physical approach[J].IEEE Transactions on Parallel and Distributed Systems.2008,19(11):1458-1472.DOI:10.1109/TPDS.2008.111.
[31]  CHOI J,GOVINDAN S,URGAONKAR B,et al.Profiling,Prediction,and Capping of Power Consumption in Consolidated Environments[DB/OL].[2016-05-02].http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4770558.DOI:10.1109/MASCOT.2008.4770558
[32]  罗亮,吴文峻,张飞.面向云计算数据中心的能耗建模方法[J].软件学报,2014,25(7):1371-1387.DOI:10.13328/j.cnki.jos.004604.LUO L,WU W J,ZHANG F.Energy modeling based on cloud data center[J].Ruan Jian Xue Bao/Journal of Software,2014,25(7):1371-1387.DOI:10.13328/j.cnki.jos.004604(Ch).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133