- 2015
基于岩土失调温度限值的土壤源热泵系统土壤蓄能状态评价Abstract: 基于岩土失调温度限值、建筑负荷特征、传热机理等多参数耦合的分析方法,提出了系统节能率、系统总运行费用现值和系统失效指标等评价指标,并建立了土壤蓄能状态评价体系.以评价体系为基础,通过CFD软件建立三维地下埋管管群数值计算模型,构建了评价全寿命周期内的土壤源热泵系统土壤蓄能状态的计算方法.计算和分析结果表明,评价体系和计算方法不仅可以较客观地反映土壤的蓄能状态,同时能够预测基于实际工程运行特性下的岩土失调温度限值范围和全寿命周期内节能性和经济性的失效时间点.Based on the analysis of multi-parameter coupling, which is based on ground source imbalance temperature limit, the building load characteristics and the heat transfer mechanism, this paper put forward an evaluation index, including the energy storage imbalance temperature limit, energy imbalance, and system invalidating indicator, and built the evaluation system on ground energy storage condition. Based on this evaluation system, by using the three-dimensional pipe-group model created by CFD software, a calculation method to accurately analyze the ground energy storage condition of ground source heat pump system was proposed. The result of calculation and analysis show that the evaluation system and calculation method reflect ground energy storage condition objectively and the ground source imbalance temperature limit can be concluded on the basis of the characteristics of practical projects in this method. The failure time of energy saving and efficiency can be predicted in the life cycle.
|