Performance Evaluation of the Thick Pinhole Gamma Rays Diagnostic System*

DOI: 10.4236/jasmi.2018.83003, PP. 25-36

Keywords: Gamma-Ray Camera, Pinhole, YAG, MCP Image Intensifier, CCD, MTF, NNPS

Full-Text   Cite this paper   Add to My Lib

Abstract:

The diagnostic methods for the profile of the radiation source were estab-lished at first based on the pinhole imaging principle. In this paper, the relationships among various parameters of the gamma-rays crammer such as the modulation transfer function (MTF), the noise power spectrum (NPS), the signal-noise ratio (SNR) and the detective quantum efficiency (DQE) are developed and studied experimentally on the cobalt radiation source. The image diagnostic system is consisting with rays-fluorescence convertor (YAG crystal), optical imaging system, MCP image intensifier, CCD camera and other devices. The spatial resolution of the modulation transfer function (MTF) at 10% intensity was measured as 1 lp/mm by knife-edge method. The quantum of the measurement system is about 150 under weak radiation condition due to the single particle detection efficiency of the system. The dynamic range was inferred preliminarily as about 437. The required radiation intensity was calculated using the experiment result for the (SNR) = 1, 5, 10, respectively. The theoretical investigation results show that the radiation image with (SNR) = 1 can be only obtained when the pinhole diameter is 0.7 mm, object distance and image distance are both 200 cm, and the radiation intensity is about 1.0 × 1012 Sr-1·cm-2.

References

[1]  Christensen, C.R. and Barnes, C.W. (2003) First Results of Pinhole Neutron Imaging for Inertial Confinement Fusion. Review of Scientific Instruments, 74, 2690-2694.
[2]  Yates, G.J. and King, N.S.P. (1997) High-Frame-Rate Intensified Fast Optically Shuttered TV Cameras with Selected Imaging Applications. SPIE Conference Proceedings, Vol. 2273, 26-149.
[3]  Vartsky, D. (2009) Signal and Noise Analysis in TRION—Time-Resolved Integrative Optical Fast Neutron Detector, Soreq NRC, Yavne 81800. Journal of instrument, 2, 1-18.
[4]  Xiang, C.C. and Chen, X.H. (2010) MTF Measurement and Imaging Quality Evaluation of Digital Camera with Slanted-Edge Method. Proceedings of SPIE, Photonics Asia, Vol. 7849, Beijing, 5 November 2010, 78490A.
https://doi.org/10.1117/12.869937
[5]  Park, H.-S. and Kim, H.-J. (2008) Measurements and Evaluation of the Image Noise Power Spectrum for Computed Radiography. 2008 IEEE Nuclear Science Symposium Conference Record, Dresden, 19-25 October 2008, 4378-4383.
https://doi.org/10.1109/NSSMIC.2008.4774252
[6]  Miévillea, F.A., Bolardbm G., et al. (2011) 3D Noise Power Spectrum Applied on Clinical MDCT Scanners: Effects of Reconstruction Algorithms and Reconstruction Filters. SPIE Medical Imaging, Vol. 7961, Orlando, 79610E.
[7]  Lubinsky, A.R. and Zhao, W. (2008) Screen Optics Effects on DQE in Digital Radiography: Spatial Frequency Effects, Proceedings of SPIE, Medical Imaging 2008: Physics of Medical Imaging, Vol. 6913, San Diego, 18 March 2008, 69134F.
https://doi.org/10.1117/12.772973
[8]  Park, H.-S. and Kim, H.-J. (2010) Effects of Image Processing on the Detective Quantum Efficiency. SPIE Medical Imaging, Vol. 7622, San Diego, 23 March 2010, 76220M.
[9]  Gang, G.J. and Zbijewski, W. (2012) Theoretical Framework for the Dual-Energy Cone-Beam CT Noise-Power Spectrum, NEQ, and Tasked-Based Detectability Index. Proceedings of SPIE, SPIE Medical Imaging, Vol. 8313, San Diego, 23 February 2012, 83131J.
https://doi.org/10.1117/12.911817
[10]  Mah, D. and Rawlinson, J.A. (1999) Detective Quantum Efficiency of an Amorphous Selenium Detector to Megavoltage Radiation. Physics in Medicine & Biology, 44, 1369-1384.
https://doi.org/10.1088/0031-9155/44/5/320
[11]  Xie, H.W., Peng, T.P., Xu, Z.P. and Chen, F.X. (2011) Thick Pinhole Design Applied to High Energy γ-Ray Source Radiographic Diagnostics. Nuclear Electronics & Detection Technology, 31, 143-147.
[12]  Cremer, J.T., Piestrup, M.A. and Wu, X.Z. (2005) Fast and Thermal Neutron Radiography. Proceedings of SPIE, Optics and Photonics, Vol. 5923, San Diego, 21 September 2005, 59230A.
https://doi.org/10.1117/12.624972

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133