IEC 61850 SCL Validation Using UML Model in Modern Digital Substation

DOI: 10.4236/sgre.2018.98009, PP. 127-149

Keywords: IEC 61850, Substation Automation, IED, XML, UML, XMI, Schema, Rule-Based SCL Validation, Syntax, Semantic Data Model, SCL Editor

Full-Text   Cite this paper   Add to My Lib

Abstract:

The IEC 61850 standard stipulates the Substation Configuration Description Language (SCL) file as a means to define the substation equipment, IED function and also the communication mechanism for the substation area network. The SCL is an eXtensible Markup Language (XML) based file which helps to describe the configuration of the substation Intelligent Electronic Devices (IED) including their associated functions. The SCL file is also configured to contain all IED capabilities including data model which is structured into objects for easy descriptive modeling. The effective functioning of this SCL file relies on appropriate validation techniques which check the data model for errors due to non-conformity to the IEC 61850 standard. In this research, we extend the conventional SCL validation algorithm to develop a more advanced validator which can validate the standard data model using the Unified Modeling Language (UML). By using the Rule-based SCL validation tool, we implement validation test cases for a more comprehensive understanding of the various validation functionalities. It can be observed from the algorithm and the various implemented test cases that the proposed validation tool can improve SCL information validation and also help automation engineers to comprehend the IEC 61850 substation system architecture.

References

[1]  Pagani, G.A. and Aiello, M. (2013) The Power Grid as a Complex Network: A Survey. Physica A: Statistical Mechanics and Its Applications, 392, 2688-2700.
https://doi.org/10.1016/j.physa.2013.01.023
[2]  Roostaee, S., Hooshmand, R. and Ataei, M. (2011) Substation Automation System Using IEC 61850. Proceedings of the 5th International Power Engineering and Optimization Conference, Shah Alam, Selangor, 6-7 June 2011, 393-397.
[3]  Brand, K.P. and Janssen, M. (2005) The Specification of IEC 61850 Based Substation Automation Systems. Paper Presented at the DistribuTech 2005, San Diego, 25-27 January 2005, 8 p.
https://library.e.abb.com/public/b0dc46b17050d26bc125705a004de6d5/Brand_Janssen_Distribu Tech2005.pdf
[4]  Adamiak, M., Baigent, D. and Mackiewicz, R. IEC 61850 Communication Networks and Systems in Substations: An Overview for Users.
http://www.gegridsolutions.com/multilin/journals/issues/spring09/iec61850.pdf
[5]  Mackiewicz, R.E. (2006) Overview of IEC 61850 and Benefits. Proceedings of the IEEE/PES Transmission and Distribution Conference and Exhibition, Dallas, TX, 21-24 May 2006, 376-383.
https://doi.org/10.1109/TDC.2006.1668522
[6]  Wagh, K.S. and More, A. (2015) Comparative Analysis of IEC 61850 Edition-I and II Standards for Substation Automation. Proceedings of the 2015 IEEE International Conference on Computational Intelligence and Computing Research (ICCIC), Madurai, 10-12 December 2015, 1-6.
https://doi.org/10.1109/ICCIC.2015.7435756
[7]  Ozansoy, R., Zayegh, A. and Kalam, A. (2009) Object Modeling of Data and DataSets in the International Standard IEC 61850. IEEE Transactions on Power Delivery, 24, 1140-1147.
https://doi.org/10.1109/TPWRD.2008.2005658
[8]  Marcadet and Lambert, E. (2016) RiseClipse: Why Working at the Model Level Is Better for Validating Data Conforming to IEC Standards. Proceedings of the 2016 Power Systems Computation Conference (PSCC), Genoa, 20-24 June 2016, 1-7.
[9]  Peng, X., Liang, Y.C., Luo, Z.P., Pan, F.L. and Li, L. (2016) Analyses and Comparisons of SCL Files in Substation Configurator. Proceedings of the 3rd International Conference on Systems and Informatics (ICSAI), Shanghai, 19-21 November 2016, 297-300.
[10]  Huo, Z.H., Zhang, L.M. and Zhang, Z.X. (2008) Research on Graphics Model Design for IEC61850 SCL Visual Configuration. Proceedings of IEEE Pacific-Asia Workshop on Computational Intelligence and Industrial Application, Wuhan, 19-20 December 2008, 700-704.
https://doi.org/10.1109/PACIIA.2008.42
[11]  Pan, Y., Sun, K.H. and Ma, L.J. (2012) Design and Implementation of Visual SCL Configurator. Proceedings of the International Conference on Automatic Control and Artificial Intelligence, Xiamen, 3-5 March 2012, 782-785.
[12]  Beil, L. and Lian-shunl, M. (2006) To Realize the SCL Configurator of IEC6 1850 Based on Relative Model. Proceedings of the International Conference on Power System Technology, Chongqing, 22-26 October 2006, 1-7.
https://doi.org/10.1109/ICPST.2006.321870
[13]  Yang, Y., et al. (2014) Comparison Method for Differentiation of IEC 61850 Based Substation Configuration Files. Proceedings of the International Conference on Power System Technology, Chengdu, 20-22 October 2014, 1796-1801.
https://doi.org/10.1109/POWERCON.2014.6993635
[14]  Konig, J., Zhu, K., Nordstrom, L., Ekstedt, M. and Lagerstrom, R. (2010) Mapping the Substation Configuration Language of IEC 61850 to ArchiMate. Proceedings of the 14th IEEE International Enterprise Distributed Object Computing Conference Workshops, Vitoria, 25-29 October 2010, 60-68.
https://doi.org/10.1109/EDOCW.2010.35
[15]  Hou, S.Z., Liu, W. and Kong, F.Y. (2013) IEC61850 Gateway SCL Configuration Document Research. Proceedings of the 3rd International Conference on Intelligent System Design and Engineering Applications, Hong Kong, 16-18 January 2013, 824-831.
https://doi.org/10.1109/ISDEA.2012.196
[16]  Vetter, C., Frei, C. and Obrist, M. (2008) Validating a Standardized Configuration Description. U.S Patent 8156061B2.
[17]  DNV GL, UniCA SCL (2017) Checker Version 3.29.
[18]  Jang, B.-T., Alidu A. and Kim, N.-D. (2017) Design of an Algorithm for the Validation of SCL in Digital Substations. KEPCO Journal on Electric Power and Energy, 3, 89-97.
[19]  Kostic, T., Preiss, O. and Frei, C. (2005) Understanding and Using the IEC 61850: A Case for Meta-Modelling. Computer Standards & Interfaces, 27, 679-695.
[20]  Zhu, Y.L., Wang, D.W., Wang, Y. and Zhao, W.Q. (2009) Study on Interoperable Exchange of IEC 61850 Data Model. Proceedings of the 4th IEEE Conference on Industrial Electronics and Applications, Xi’an, 25-27 May 2009, 2724-2728.
https://doi.org/10.1109/ICIEA.2009.5138698
[21]  (2013) Communication Networks and Systems for Power Utility Automation Part 7-3: Basic Communication Structure—Common data classes, IEC 61850 Standard.
[22]  (2013) Communication Networks and Systems for Power Utility Automation Part 7-4: Basic Communication Structure—Compatible Logical Node Classes and Data Object Classes, IEC 61850 Standard.
[23]  Apostolov, A.P. (2010) UML and XML Use in IEC 61850. IEEE PES T&D 2010, New Orleans, LA, USA, 19-22 April 2010, 1-6.
https://doi.org/10.1109/TDC.2010.5484325
[24]  Kim, N.-D., Alidu, A., Jang, B.-T., Lee, N.H. and Yun, Y.B. (2017) Using UML Data Model for SCL Validation. Proceedings of the KIEE—The Korean Society of Power Engineering Proceedings Spring Conference on Power Systems, Hyatt Hotel Jeju South Korea, 23-25 March 2017, 229-231.
[25]  (2013) Communication Networks and Systems for Power Utility Automation Part 6: Configuration Description Language for Communication in Electrical Substations Related to IEDs, IEC 61850 Standard Part 6.
[26]  Young, P. and Stevens, J. Consistency and Completeness Checking of 61850 SCL Files for Compliance and Interoperability.
http://trianglemicroworks.com/docs/default-source/referenced-documents/consistency-and-completeness-checking-of-61850-scl-files.pdf?sfvrsn=4
[27]  Stephen Gerspach, C.V. and Maeda, T. (2006) Intelligent Electronic Device Configuration Inspection. European Patent No. US8165841B2, ABB Zurich.
https://patentimages.storage.googleapis.com/24/28/a9/76c9a98ce230fe/US8165841.pdf

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133