Water conservation initiatives promote installation of water efficient and low-flow appliances in waste water collection systems. This has resulted in lower flow rates in those systems than the intended design loading, causing solid deposition and sedimentation in some areas. A joint UKWIR/EPSRC CASE grant (14440031) has funded the work described in this paper which investigates sedimentation and solid deposition in building drainage system pipes. The purpose of this paper is to detail the design, calibration and operation of a sediment dosing apparatus to simulate sedimentation rates and explore possible solutions to this issue with a full scale laboratory model based on real site data. The methodology adopted is an experimental approach, where tests have been conducted on the sediment dosing apparatus based on calculations and observations to determine an appropriate sediment dosing regime representative of typical systems. Further tests were conducted with the addition of everyday household products to investigate their effects on sedimentation. The results indicated that a suitable dosing rate was approximately 12% weight-to-volume (w/v) of a fine sand with a known particle size distribution, diluted 1:5 in a clean water base flow. It was also shown that the addition of the household products added to the problem of sedimentation within drainage systems. The results give excellent correlation to real site data, with deposition depth and distribution comparable to measured site data to within 10%. The deposition was achieved within three hours, which approximated six weeks deposition in the live site used in the study. This straightforward investigation details the design, construction and testing of a device to cause accelerated sedimentation in a full scale model of a building drainage system. This is the first step in the process of updating research underpinning our understanding of the behaviour of these systems under conditions of low flow rates caused by water conservation, sedimentation, and the use of common household additives. It will be used to improve simulation of water flow and solid transport in sediment-laden systems. Specifically, the results will be used to determine refinements required to a specific drainage simulation model (DRAINET), which currently has an unquantified sedimentation component. This work is part of a larger body of current research funded by two joint EPSRK/UKWIR grants.
References
[1]
May, R., Brown, P., Hare, G. and Jones, K. (1989) Self-Cleansing Conditions for Sewers Carrying Sediment. Hydraulics Research Ltd., Wallingford, Oxfordshire. http://eprints.hrwallingford.co.uk/1087/1/SR221.pdf
[2]
May, R. (1993) Sediment Transport in Pipes and Sewers with Deposited Beds. HR Wallingford, Wallingford, Oxfordshire.
[3]
Hodgkins, L. (2016) Stokes’ Law and Terminal Velocity. http://www.schoolphysics.co.uk/age16-19/Properties%20of%20matter/Viscosity/text/Stokes_law/index.html
[4]
Coleman, S., et al. (2003) Closed-Conduit Bed-Form Initiation and Development. Journal of Hydraulic Engineering, 129, 12.
[5]
Escarameia, M. and Lauchlan, C. (2005) Implications of Site Drainage Systems of Reduced Capacity. Environmental Hydraulics and Sustainable Water, 131, 189-211.
[6]
UKWIR Technical Report (2018) Flow Modelling of Urban Water Distribution Systems Using Water Conservation Fittings, UKWIR Reference 18/CL/12/3.
[7]
UKWIR Technical Report. (2016) Integration of Behavioral Change into Demand Forecasting and Water Efficiency Practices, UKWIR Reference 16/WR/01/15.
[8]
Campbell, D.P. (2008) Impacts of Low Water Consumption Fittings in the UK Drainage Infrastructure. CIBW62 International Symposium on Water Supply and Drainage for Buildings, Brussels, 16 September 2008, 104-119.
[9]
Campbell D.P. ,et al. (2011)Developments in Mathematical Simulation of Fluid Flow in Building Drainage Systems Building Service Engineering Research & Technology 33, 1-11.
[10]
McDougall, J. (2003) The Influence of Water Conservation on Drain Sizing for Building Drainage Systems. Building Services Engineering Research and Technology, 24, 229-243. https://doi.org/10.1191/0143624403bt074oa
[11]
Wise, A.F.E. (1986) Water, Sanitary and Waste Services for Buildings. 2nd Edition, Mitchel, London.
[12]
Swaffield, J.A. and Galowin, L.S. (1992) The Engineered Design of Building Drainage Systems. Ashgate Publishing Limited, England.
[13]
Swaffield, J.A. and McDougall, J.A. (2000) Simulation of Building Drainage System Operation under Water Conservation Design Criteria. Building Services Engineering Research and Technology, 21, 45-55.
[14]
May, W.P., et al. (1996) Development of Design Methodology for Self-Cleansing Sewers. Water Science & Technology, 33, 195-205. https://doi.org/10.1016/0273-1223(96)00387-3
[15]
Swaffield, J.A., McDougall, J.A. and Campbell, D.P. (1999) Drainage Flow and Solid Transport in Defective Building Drainage Networks. Building Services Engineering Research and Technology, 20, 73-82.
[16]
Gormley, M., Campbell, D.P. and McDougall, J.A. (2004) The Interaction of Solids in Near Horizontal Drainage Pipes. CIBW62 Symposium on Water Supply and Drainage for Buildings, Paris, September 2004, 277-289.
[17]
BSI (2000) BS EN 12056-2:2000 Gravity Drainage Systems inside Buildings. BSI, London.
[18]
BSI (2008) BS 6700:2006 Design, Installation, Testing and Maintenance of Services Supplying Water for Domestic Use within Buildings and Their Curtilages—Specification. BSI, London.
[19]
Butler, D. and Davies, J. (2004) Urban Drainage. 2nd Edition, Spon Press, London.
[20]
Campbell, D.P. (2011) Experimental Application of Particle Imaging to Fluid Velocity Analysis in Building Drainage Systems. Building Service Engineering Research & Technology, 32, 263-275. https://doi.org/10.1177/0143624410396428
[21]
Campbell, D.P. and MacLeod, K.A. (2000) Detergency in Drainage-Waste-Ventilation (DWV) Systems. Building Service Engineering Research & Technology, 21, 35-40.
[22]
Campbell, D.P. and MacLeod, K.A. (2001) Detergents in Drainage Systems for Buildings. Water Research, 35, 1086-1092.